SOIL BEARING & FOUNDATION NOTE: <br />NO SOIL REPORT WAS PROVIDED FOR THIS DESIGN. <br />IN ACCORDANCE WITH SECTION 1803.2 OF THE FLORIDA BUILDING CODE <br />2020 (7TH EDITION), THE BUILDING OFFICIAL SHALL BE PERMITTED TO <br />WAIVE THE REQUIREMENT FOR A GEOTECHNICAL INVESTIGATION WHERE <br />SATISFACTORY DATA FROM ADJACENT AREAS IS AVAILABLE THAT <br />DEMONSTRATES AN INVESTIGATION IS NOT NECESSARY FOR ANY OF THE <br />CONDITIONS IN SECTIONS 1803.5.1 THROUGH 1803.5.6 AND SECTIONS <br />1803.5.10 AND 1803.5.11. <br />IN LIEU OF A GEOTECHNICAL EVALUATION, AND IN ACCORDANCE WITH <br />THE STATEMENT ABOVE, THE STRUCTURE'S FOUNDATION HAS BEEN <br />DESIGNED ASSUMING A 2,000 PSF ALLOWABLE SOIL BEARING CAPACITY, <br />SELECTED FROM FBC TABLE 1806.2. THE PRESUMPTIVE LOAD BEARING <br />VALUE HAS BEEN SELECTED BASED ON RATIONAL ANALYSIS AND <br />KNOWLEDGE OF OTHER PROJECTS IN THE VICINITY. IF AT ANY TIME <br />DURING EXCAVATION ANY DELETERIOUS MATERIAL (SUCH AS LOOSE <br />SOIL, SILT, PEAT, MUCK, CLAY, ETC.) IS FOUND THAT CANNOT PROVIDE <br />2,000 PSF, THE ENGINEER OF RECORD SHALL BE CONTACTED TO <br />PROVIDE DIRECTION. <br />THIS STATEMENT IS BASED UPON SECTIONS 1802.1, 1803.2, 1803.3 AND <br />1806.2 OF THE FLORIDA BUILDING CODE 2020 (7TH EDITION). <br />CONTRACTOR SHALL BACKFILL AND COMPACT ALL EXCAVATIONS, <br />DISTURBED AREAS, AND VOIDS WITH CLEAN, GRANULAR SOIL <br />COMPACTED AND CERTIFIED TO 95% MODIFIED PROCTOR DENSITY AND <br />MINIMUM 2,000 PSF ALLOWABLE BEARING CAPACITY. <br />REIr <br />#4 <br />CEN TEF <br />CONCRETE & REBAR: <br />CONCRETE IS TO BE A MIX DESIGNED IN ACCORDANCE WITH ASTM C-94 BY A RECOGNIZED <br />TESTING LABORATORY TO ACHIEVE A STRENGTH OF 4,000 PSI, AT 28 DAYS, (UNLESS <br />OTHERWISE NOTED) WITH A PLASTIC AND WORKABLE MIX AND A MAX. WATER TO CEMENT <br />RATIO = 0.40. <br />PNEUMATICALLY APPLIED CONCRETE AND/OR SHOTCRETE SHALL BE PLACED IN <br />ACCORDANCE WITH ACI 304.2R-04 AND ACI 506.2-04, RESPECTIVELY. <br />ALL OTHER CONCRETE SHALL BE PLACED IN ACCORDANCE WITH ACI 304R-04. <br />A CERTIFICATE OF MANUFACTURER'S MIX AND STRENGTH IS TO BE PROVIDED. <br />NO WATER IS TO BE ADDED AFTER TRUCK LEAVES PLANT WITHOUT APPROVAL OF THE <br />ENGINEER. PLANT CONTROL IS REQUIRED. <br />MAXIMUM MIX TIME AT POINT OF DEPOSIT IS 90 MINUTES. CONCRETE WORK SHALL BE AS <br />PER REQUIREMENTS AND RECOMMENDATIONS OF ACI 301-04. <br />REBAR SHALL BE A615 GRADE 60 OR BETTER (UNLESS OTHERWISE NOTED), FREE FROM OIL, <br />LOOSE SCALE AND LOOSE RUST. <br />REBAR SHALL BE BENT, LAPPED, PLACED, SUPPORTED AND FASTENED ACCORDING TO THE <br />MANUAL OF STANDARD PRACTICE FOR DETAILING CONCRETE STRUCTURES (ACI 315-04) <br />AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI-318-19). IN <br />CASE OF CONFLICT, THE MORE CONSERVATIVE VALUE(S) SHALL BE USED. <br />SUN SHELF STRUCTURAL DETAIL <br />SCALE: N.T.S. <br />SLAB OR WALL <br />REINFORCEMENT <br />(REFER TO PLAN) <br />(1)#4FOR "T"=8"ORL <br />(2) #4 FOR "T" OVEF <br />MIN. (2) #4 AT MAIN Df <br />OPENING OR <br />PENETRATION_ <br />THROUGH <br />WALL OR SLAB <br />ESS <br />' 8" <br />!AIN <br />2'. <br />CLEAR <br />MIN. <br />3' <br />ADD AT EACH SIDE OF OPENING <br />1/2 OF SLAB OR WALL REINF <br />INTERRUPTED BY OPENING <br />NOTE: <br />THE STRUCTURE HAS BEEN DESIGNED ASSUMING MONOLITHIC CONSTRUCTION <br />(NO COLD JOINTS). ADDITIONAL DETAILS WILL BE REQUIRED IF MONOLITHIC <br />CONSTRUCTION IS NOT ACHIEVED AND/OR COLD JOINTS ARE INTRODUCED. <br />SPLICES IN REINFORCING BARS SHALL BE NOT LESS THAN 48X BAR <br />DIAMETERSSHALL CONFORM TO FBC-B 1908.4.3 (NON -CONTACT OR <br />CONTACT WITH TEST PANEL AND APPROVAL BY THE BUILDING OFFICIAL). <br />REINFORCEMENT SHALL BE CONTINUOUS AROUND ALL CORNERS AND <br />CHANGES IN DIRECTION. CONTINUITY SHALL BE PROVIDED AT CORNERS OR <br />CHANGES IN DIRECTION BY BENDING THE LONGITUDINAL STEEL AROUND THE <br />CORNER 48X BAR DIAMETERS OR BY ADDING MATCHING REINFORCING STEEL, <br />WHICH SHALL EXTEND MIN. 48X BAR DIAMETERS FROM EACH CORNER OR <br />CHANGE IN DIRECTION. WHEN THREE OR MORE BARS ARE REQUIRED, THE <br />BARS SHALL BE HELD IN PLACE AND ALIGNED BY TRANSVERSE BARS <br />SPACED NOT MORE THAN 4 FEET (1219 MM) APART. <br />DISCONTINUOUS REINFORCING BARS SHALL TERMINATE IN STANDARD ACI <br />HOOKS. ALL HOOKS SHALL BE STANDARD ACI HOOKS UNLESS NOTED <br />OTHERWISE. <br />_SLAB OR WALL REINFORCEMENT <br />INTERRUPTED AT OPENING <br />NOTES: <br />1. TYPICAL AT ALL SLAB OPENINGS OR PENETRATIONS. <br />2. "T" = WALL OR SLAB THICKNESS <br />3. PROVIDE ADDITIONAL BARS (NOT SHOWN) WHICH EQUAL THE AREA OF INTERRUPTED <br />WALL & SLAB REINFORCING. <br />4. PLACE IN ADDITIONAL REBAR IN EQUAL AREAS EACH SIDE OF OPENING AND <br />PARALLEL TO THE CONTINUOUS REINFORCEMENT ALONG THE PERIMETER OF THE <br />OPENING. <br />5. BUNDLE BARS IAW ACI 318 AT RESTRICTED AREAS. <br />PENETRATION/OPENING DETAIL <br />SCALE: N.T.S. <br />NOTE: <br />ALL FINISHES SHOWN ON THESE DRAWINGS ARE GENERIC. <br />ALL FINISH MATERIALS (INCLUDING, BUT NOT LIMITED TO, <br />ADHESIVES, GROUTS, AND BONDING AGENTS) SHALL BE <br />MANUFACTURER SPECIFIED AS SUITABLE FOR USE IN <br />POOL/SPA APPLICATIONS. <br />ALL MATERIAL INSTALLATIONS SHALL COMPLY WITH FBC, ALL <br />[RELEVANT INDUSTRY STANDARDS, AND ALL MANUFACTURER <br />INSTRUCTIONS AND SPECIFICATIONS. <br />ALL MATERIALS AND FINISHES USED ON HORIZONTAL <br />SURFACES SHALL BE SLIP RESISTANT WHEN WET. <br />DOTE: <br />FHESE PLANS DO NOT INCLUDE ALL TECHNICAL <br />;PECIFICATIONS REQUIRED FOR CONSTRUCTION. CONTRACTOF <br />;HALL REFERENCE ALL MANUFACTURER INSTRUCTIONS AND <br />;PECIFICATIONS. <br />NOTE: FLOORS AND WALLS SHALL BE WHITE OR PASTE_ IN COLOR AND <br />SHALL HAVE THE CHARACTERISTICS OF REFLECTING RATHER THAN <br />ABSORBING LIGHT. THE FINISH COATING SHALL HAVE A DRY LIGHTNESS <br />LEVEL (CIE L VALUE) OF 80.0 OR GREATER AND A WET LUMINOUS <br />REFLECTANCE VALUE (CIE Y VALUE) OF 50.0 OR GREATER, AS <br />DETERMINED BY TEST RESULTS PROVIDED BY TH = MANUFACTURER, <br />UTILIZING TESTING METHODOLOGY FROM AMERICAN STANDARD ASTM <br />D4086, ASTM E1477, ASTM E1347. POOLS CONSTRUCTED OF FIBERGLASS, <br />THERMOPLASTIC, OR STAINLESS STEEL SHALL BE SUBJECT TO THE SAME <br />INTERIOR FINISH COLOR REQUIREMENTS. <br />OPERATING <br />WATER LEVEL <br />3'-6" DEEP <br />AT <br />SHALLOW END <br />6' THICK <br />GUNITI_ WALL <br />4'-9 REINFORCED W/ <br />DEEP #4 ® 12" O.C.E.W <br />AT PROVIDE 2" CLEAR CONCRETE COVER FROM WATEF <br />DEEP END PROVIDE 3" CLEAR CONCRETE COVER FRCM SOIL <br />NOTE: <br />PROVIDE MIN. 3" CLEAR <br />CONCRETE COVER FROM <br />WATER IN SLAB. <br />PROVIDE MIN. 3" CLEAR <br />CONCRETE COVER FROM <br />SOIL IN SLAB. <br />8" THICK <br />APPROVED GUNITE SLAB <br />FINISH REINFORCi=D W/ <br />#4 ® 12" C.C.E.W. <br />CENTERED IN SLAB <br />2" MIN <br />3" MIN. <br />GUTTER 6j" <br />(REFER TO FINISHED <br />DETAIL) <br />2" CLEAR <br />m <br />MIN. <br />24" <br />LAP <br />HIGH <br />POINT, <br />TYP. <br />6" <br />ROUGH <br />t 3" CLEAR <br />Q, <br />1 <br />�CLEAN, GRANULAR <br />SUBGRADE COMPACTED <br />TO 95% MOD. PROCTOR AND <br />MIN. 2,000 PSF <br />ALLOWABLE BEARING CAPACITY <br />FLOOR/WALL STRUCTURAL DETAIL <br />SCALE: N.T.S. <br />David <br />Faerman, <br />Pi OE <br />MIN. 48" CLEAR <br />WET DECK <br />(REFER TO <br />SITE PLAN) <br />WET DECK <br />SHALL <br />SLOPE <br />2% AWAY <br />TOWARD <br />PERVIOUS <br />AREA <br />11-� <br />1'-2j" <br />CLEAN, GRANULAR <br />BACKFILL COMPACTED <br />TO 95% MOD. PROCTOR AND <br />MIN. 2,000 PSF <br />ALLOWABLE BEARING CAPACITY <br />NOTE: <br />POOL STRUCTURE SHALL BE FULLY <br />SUPPORTED BY SOIL. <br />Digitally signed <br />by David <br />Faerman, RE <br />Date: 2023.01.13 <br />16:26:29—05'00' <br />z <br />__j <br />wO <br />0 <br />Q <br />m <br />Z <br />O <br />0 <br />Q � � <br />u <br />z O <br />U <br />cl:� <br />z <br />C) J J <br />LLJ <br />_ <br />0 <br />O <br />> <br />I <br />a <br />Q <br />a- <br />]—Z— <br />J N <br />LLJ <br />cn <br />N <br />C� <br />7 <br />N <br />N <br />N <br />O <br />all <br />�LL_I <br />O <br />O <br />rT� <br />h-��1 <br />[-- <br />ry <br />F.L. <br />OO <br />Ld <br />Of <br />ct <br />a_ <br />� <br />� <br />HMO <br />N <br />m <br />C) <br />W <br />Q <br />W <br />c <br />W <br />� <br />z <br />W CO <br />N 00 't <br />> <br />o rs I co <br />LLJ -i Lo <br />OOW <br />�75 N <br />Z �- z <br />� <br />F co Q <br />C <br />Q F—)007 <br />�Q 00W <br />f,Q U,IL. <br />C LL Q <br />N <br />m 0 Q <br />Ld <br />PROJECT NO. <br />22C093 <br />QO <br />0 <br />~ <br />z o ZU <br />Z W <br />Qinwa <br />= <br />�~ <br />oLi< <br />Qo> <br />z�Q= <br />zzQ <br />a <br />�nrl <br />woZ <br />JZ1cd <br />Q:2za <br />�ofcn0 <br />OWuw <br />O(n� <br />o�Qo <br />mQ> <br />z-tea <br />W w <br />mvi <br />oo w <br />mS <br />cnczac~i)a <br />(nQz04 <br />WLn1� <br />=>- <br />OLou WU <br />N <br />H_oww <br />00 <br />lQ <br />J Z N <br />Of <br />HQ ~ <br />�aC7LLJ <br />1E <br />U <br />ZZZW <br />O <br />W Z 2 <br />(nW�-cD <br />J <br />dU(nW <br />\0�0 j� F A E,;M% <br />`•��QQ •��CENSF•'4�'''% <br />* ; No. 47646 ; <br />r STATE OF <br />�S•.,, O R I <br />01 /13/2023 <br />DAVID I FAERMAN, P.E. <br />FL. LICENSE NO. 47646 <br />PERMIT SET <br />NO, I DATE I DESCRIPTION <br />SHEET <br />9 OF 11 <br />