Laserfiche WebLink
TYPICAL DECK LAY-UP <br />1. START LAYING DECK AT CORNER W/ TONGUES <br />OUTWARD IN DIRECTION OF LAYING. <br />2. DRIVE COURSES TIGHT W/ BLOCKING. <br />3. ATTACH DECKING PER DETAILS ON SHEET 5. <br />DECK PLAN AT CORNERS <br />FASCIA NOTES: <br />1. ALL FASCIA CORNERS AND SPLICES ARE TO BE MITERED. <br />2. SEE DETAIL A FOR SPLICE DETAIL. <br />3. ATTACH FASCIA WITH 10d HDG CASING NAILS: <br />a. TO 2x4 NAILER - 24" O.C. <br />b. TO ENDS OF ROOF DECKING - 1 NAIL PER DECK BOARD <br />c. AT CORNERS - 2 NAILS EACH DIRECTION <br />d. OTHER LOCATIONS - 24" O.C. TO ROOF DECKING <br />2 x 4 NAILER <br />A. MITER ALL SPLICES <br />B. NAIL SPLICES TOGETHER WITH (2) 10d HDG CASING NAILS, DRIVE <br />NAILS AT AN ANGLE TO AVOID PUNCHING THRU FASCIA. <br />6-0" MIN. TO Z-0" MIN. <br />ROOF CORNER FASCIA SPLICE <br />NAILER SPLICE <br />! --- ---- --- —1 <br />DETAIL A <br />(2)-16d PER DECK BOARD <br />FASCIA --' V/ <br />SECTION <br />FASCIA <br />\.-- NAILER <br />DECKING <br />METAL DECK <br />NOT SHOWN <br />HOOD DECK <br />NAILER <br />\S-2 — — <br />I <br />F\ <br />I I \ <br />F <br />ROOF DECK SUPPLIER TO PROVIDE A \ <br />UNIVERSAL HIP/RIDGE CAP. SEE DECK <br />DETAIL FOR ATTACHMENT. I <br />m <br />I <br />I <br />I L9 <br />m <br />I <br />I I <br />1-3-1 <br />4" x 26ga. x 50ksi MAX Min MMnrAk11,-"=^ o^^ff """in, Ll <br />(T-0" COVERAGE PEF <br />ATTACHMENT. OVEF <br />DECKING. <br />SEE EAVE DETAIL ON <br />SHEET 5 <br />011 <br />cn <br />I <br />v� can <br />F-1 <br />10'-9" <br />24'-0" OUT/OUT FASCIA <br />FRAMING PLAN <br />SCALE: 1 /4" = V-0" <br />5t(; I ION A <br />1 <br />M <br />b> <br />0 <br />N <br />� I <br />I I <br />I <br />I q <br />I o <br />I <br />I I <br />I <br />I I <br />Q <br />I <br />U <br />I <br />� <br />I <br />Q <br />� <br />I <br />— <br />O <br />JI <br />Ell <br />10'-9" <br />0 <br />0 <br />o� <br />b <br />N <br />I <br />I <br />TI(1f <br />I <br />I <br />M <br />1'-3" <br />W <br />DESIGN CRITERIA: <br />CONTRACT NOTE: <br />2010 Florida Building Code <br />Reference accepted proposal and/or executed contract for identification of items furnished by RCP Shelters, Inc. Any item <br />Type of Construction: Type III-B <br />not specifically included shall be provided by owner, installer or others. Some items are specifically noted as N.I.C. (not in <br />Occupancy Classification: Assembly A-3 <br />contract). <br />Building Occupancy Category II <br />Mean Roof Height = 10'-0" <br />SOLID TIMBER SPECIFICATIONS <br />Building Volume = 10,000 ft3 <br />2 x 4 Nailer ----------- #1 SYP, S4S, KD, Seal <br />No. of Occupants = 150 (7 ft2 per person) <br />2 x 6 Fascia ---------- #1 SYP, S4S, KD, PENTA TYPE C 0.3 pcf, Seal. <br />2 x 8 Roof Deck ----- #1 SYP, T&G, S/L, CM, EV1 S, KD, Seal. <br />ROOF DL <br />Deck furnished in specified lengths (S/L), not precision end trimmed (PET), field cutting required. <br />Metal Roofing & Felt 1.2 psf <br />Nom. 2" T&G Deck 4.6 <br />STEEL & HARDWARE SHOP NOTES: <br />Misc. 1.2 <br />1. All steel plate to be ASTM A36. <br />Total = 7.0 psf + weight of framing <br />2. Steel tubes to be ASTM A500 Grade B, Fy=46ksi. <br />3. Steel pipes to be ASTM A500 Grade B, Fy=42ksi. <br />FLOOR LL <br />4. All welding is to be done in accordance with latest AWS standards. If welds are not specified, all welds are to develop full <br />L = 100 psf <br />strength of all component parts. <br />5. All bolts to be ASTM A325. Exception: Anchor bolts and all bolts smaller than 1 /2"0 to be A307. <br />ROOF LL <br />6. All holes in steel to be 13/16"0 unless noted otherwise. <br />Lr = 20 psf <br />7. All fabricated steel to be hot -dipped galvanized <br />8. Hardware (bolts, nuts, washers, etc.) to be furnished black unless noted to be hot -dipped galvanized. Shop to verify hole <br />WIND LOAD <br />tolerances and tolerances of threaded parts for compatibility of the galvanized parts only. <br />Risk Category II <br />Vult = 140 mph, Vasd = 109 mph <br />ERECTION NOTES: <br />Exposure 'C', Open Building w/ GC I = 0 <br />Component & Cladding Wind Presgu' res: See this sheet <br />All steel members must be properly braced until the complete structural system has been constructed. Correction of minor <br />drift be legitimate <br />misfits and a reasonable amount of reaming or alignment with pins will considered a expense of erection. <br />In the event of error, defect in materials, and/or workmanship of shop work which prevents proper assembling and fitting up <br />of parts by the moderate use of drift pins, or reaming, immediately report to the seller and obtain seller's approval of the <br />method of correction. <br />Bolts through slotted holes in steel are to be left finger tight only to allow for future movement. Other bolts are to be snug <br />tight. Torque measurement is not required. <br />NOTE: This building has been designed as a free standing, open structure. If walls are to be added, or if the building is to <br />adjoin another structure, or if other modifications are to be made, the structure must be re -engineered prior to these <br />modifications (by others). <br />� <br />METAL ROOFING NOTES: <br />CLEAR PROTECTIVE FILM MUST BE REMOVED FROM ALL METAL <br />PRIOR TO INSTALLATION. <br />METAL ROOFING SHOULD BE STORED INDOORS OR WHEN <br />STORED OUTSIDE IT SHOULD BE STORED UP ON BLOCKS WITH <br />FINISHED FACE UP AND SLOPED TO DRAIN. <br />DURING INSTALLATION, ALL METAL SHAVINGS MUST BE <br />REMOVED IMMEDIATELY TO AVOID RUSTING OF PANELS. <br />HARDWARE PARTS LIST <br />QUANTITY <br />LOOSE <br />ATTACH <br />HARDWARE DESCRIPTION <br />PART NO. <br />REMARKS <br />12 <br />L <br />1/2"0 x 2" BOLT <br />H325P 050 0200 <br />16 <br />L <br />1/2"0 x 3" BOLT <br />H325P 050 0300 <br />12 <br />L <br />1/2"0 x 7 1/2" BOLT <br />H325P 050 0750 <br />8 <br />L <br />3/4"0 x 8" BOLT <br />H325P 075 0800 <br />6 <br />L <br />3/4"0 x 8 1/2" BOLT <br />H325P 075 0850 <br />12 <br />L <br />1/2"0 HEX NUT <br />HN325P 050-13 <br />28 <br />A <br />1/2"0 HEX NUT <br />HN325P 050-13 <br />14 <br />L <br />3/4"0 HEX NUT <br />HN325P 075-10 <br />16 <br />L <br />4 1/2" SQ. COVERPLATE ASSEMBLY <br />CPA-1 <br />GALV. <br />14 <br />L <br />5 1/2" SQ. COVERPLATE ASSEMBLY <br />CPA-3 <br />GALV. <br />24 <br />L <br />3/4"0 x 24" (A307) ANCHOR BOLT <br />N.I.C. <br />24 <br />L <br />1/4" x 3" SQ. WASHER <br />N.I.C. <br />48 <br />L <br />3/4"0 HEX NUT (ANCHOR & LEVELING) <br />N.I.C. <br />L <br />10d NAIL <br />N.I.C. <br />L <br />16d NAIL <br />N.I.C. <br />1200 <br />L <br />1/4"-20 x 3" THREAD CUTTING SCREW <br />HTCSF 025 0300 1 <br />#1 <br />COL_ 7­ 7 <br />o � <br />3 O ��i 3 O� <br />\l <br />ROOF PLAN <br />a = 3'-0" <br />ULTIMATE DESIGN PRESSURES FOR COMPONENTS & CLADDING <br />ZONE <br />PRESSURE <br />SUCTION <br />2 <br />63 PSF <br />58 PSF <br />3 <br />81 PSF <br />75 PSF <br />THIS PRINT IS THE PROPERTY OF RCP <br />SHELTERS AND IS NOT TO BE USED, <br />COPIED, OR REPRODUCED WITHOUT <br />THEIR EXPRESSED WRITTEN PERMISSION, <br />Z <br />Y <br />� <br />J <br />W <br />F- <br />J <br />J <br />U <br />Z <br />w <br />rNn <br />W <br />L <br />N <br />r.J <br />V J <br />U <br />LO <br />J <br />o <br />= <br />Q <br />o <br />U) <br />E <br />0) <br />U <br />U <br />ti <br />Jm <br />m <br />NO <br />+r <br />LL <br />co <br />00 <br />Q <br />■ <br />■ <br />N <br />'` <br />a <br />U <br />Z�Y� <br />ti <br />0 <br />•_ <br />"Q_(DM <br />m <br />v / <br />LU <br />O <br />■ <br />■ <br />W <br />U) <br />Z <br />U) <br />W <br />w <br />I- <br />(n <br />J <br />W <br />LU <br />� <br />W <br />ZO <br />_Z <br />M <br />U <br />� <br />■ <br />■ <br />U_ <br />W <br />Z <br />J <br />o <br />E <br />8Q <br />OJ <br />W <br />UH <br />N <br />c,o0�, <br />Z <br />' <br />L.L <br />a. <br />m <br />oo <br />s <br />Q <br />Q <br />O <br />w <br />0 <br />a <br />UNLOADING, HANDLING & STORAGE OF DECKING (0 J W <br />DECKING WILL BE DELIVERED IN BANDED BUNDLES, WEIGHING APPROXIMATELY ONE TON. BUNDLES SHOULD REMAIN BANDED UNTIL DECK IS TO BE N = W <br />INSTALLED. A FORKLIFT OR SMALL CRANE WILL BE REQUIRED FOR UNLOADING. BE SURE TO USE NON -MARRING SLINGS. IF STORED TEMPORARILY, DECK SHOULD BE w W <br />PLACED ON BLOCKS & LEVELED, WELL OFF OF THE GROUND. IF WOOD DECKING IS WET &/OR STAINED, CONTACT RCP SHELTERS AND DO NOT INSTALL DECK. ■ ■ <br />IT IS THE ERECTORS RESPONSIBILITY TO TALLY THE DECKING UPON ARRIVAL. NOTIFY "RCP SHELTERS" AT ONCE OF ANY SHORTAGES. <br />i (} 0 ►.ilt <br />l <br />Daniel P :°� <br />PROJ. NO.: <br />Seymour 14-221-A <br />Daniel P. Seymour, P.E. <br />2014.1 2.23 Enterprise Engineering Consultants, LTD. <br />710 French Street °� CJT 12-18-14 <br />07:46:37 -061001 Peshtigo, WI 54157 CHK'D: DPP 12-19-14 <br />FL Corp. Certificate No.: F00000005724 <br />FL PE. NO.: 71972 <br />DESIGN CERTIFICATION FOR. REV 1: <br />BUILDING SIZE: 24' x 44' ``0%J11uts�j'�' <br />REV 2: <br />BUILDING LOCATION: ZEPHYRHILLS, FL ,�� �� E"sF�'0 e" REV 3: <br />THIS CERTIFICATION OF DRAWINGS IS FOR THE ONE REV 4: <br />` �No. PE71872� ' <br />BUILDING ONLY AT THE SITE LISTED ABOVE. IT IS VALID* c SHOP DWG NO.: 10722R1 <br />ONLY IF THE MATERIALS SHOWN ON THESE DRAWINGS =-W )W, <br />E <br />ARE FURNISHED BY RCP SHELTERS, INC. AND ONLY IF %\ STATE IF ) EEC JOB NO.: 10722 R V <br />MATERIALS ARE PAID FOR IN FULL. lo ;P `��OR►� W" �.`� <br />.4 ............. ��``�� SHEET NO.: <br />IF MODIFICATION IS MADE WITHOUT EXPRESSED WRITTEN <br />CONSENT OF RCP SHELTERS, INC., OR IF PAYMENT IS NOT OF 6 <br />MADE IN FULL, THEN CERTIFICATION BECOMES NULL & VOID. <br />