Laserfiche WebLink
SYMMETRICAL <br />NOTE: PENDING WHICH TYPE OF TRUSSES ARE <br />ORDERED (TOP CHORD BRG OR TRUSSES BUCKETING <br />INTO MASONRY) CONTRACTOR IS TO FOLLOW THE D1 <br />SHEET REQUIRED DUE TO THE TYPE OF TRUSSES TO <br />BE INSTALLED. OTHER D1 SHEET CAN BE IGNORED OR <br />REMOVED. (TRUSS LEDGER IS PRIMARY DESIGN w/ <br />BUCKETS AS THE OPTION) <br />LOW ROOF / FLOOR FRAMING PLAN <br />SCALE: /4"=V-0" <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />I SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />p <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 10d x 1 1/2" <br />B <br />I HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 112" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />IFGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3"SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />-- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26j 10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. / 26 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />— <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 wl (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 "" <br />1005/915 '* <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />- <br />8 -10d <br />P <br />HUS26 <br />1320/3235 "" <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 "" <br />1720/3125 "* <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />— <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />wl (24) 1/4" x 3" SIDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />w/ SIMPSON "SET' <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8"jw/EMBED <br />EMBED w/ USP <br />EPDXY <br />V <br />(2)LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/( 16 SI <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 1/2" <br />SP1 <br />555 <br />535 <br />10-10d <br />SPT22 <br />735 <br />8-10d <br />SP2 <br />1 1010 <br />1 605 <br />1 12-10d <br />SPT24 <br />1090 <br />_ <br />12-10d <br />HCP2 <br />1 590 <br />1 555 <br />1 12-10d x 1 1/2" <br />HHCP2 <br />680 <br />570 <br />(20)1 Od x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 O <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />j (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />x CONT LEDGER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ENCLADDNG W NDFPRESSURES AND SUCTIONS DESIGN <br />MEAN ROOFOHEIGHT:5 5 ftND <br />RSH <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SO FEET) () VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=oft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />HIP -35.94 -49.57 -49.57 -49.57 <br />0 <br />1 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): r <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD r <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: Q Q <br />SHINGLE: %6" EXP. 1 (2Y16) or 15/32" EXP. 1 (33/16) <br />TILE: 1V32" EXP. 1 (3�1'6) r <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y8" x 0.113") NAILS r 3r <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1Y3Z, SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2Yz" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[12:121 <br />@ 16" O.0 FIRST 4 BAYS WITH (2)12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />� O <br />cV <br />0. C14 <br />�_ <br />01 <br />(C <br />�' '- <br />U <br />a <br />NW <br />Q <br />J <br />,. <br />�.j <br />t7! <br />IffQ. n <br />r <br />4 L <br />C U <br />W <br />Q. O <br />N <br />CV <br />O <br />N <br />_o <br />M <br />` F'• <br />.. <br />•NO P+ 750 .' <br />:'0_• STATE <br />�'• <br />C <br />Al <br />To the hest of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code . <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />rA <br />W) <br />�E tp <br />8 iErZ <br />t� <br />Q <br />N <br />03 ° � " <br />L� W <br />q <br />Ot <br />�r-r�.- W °_ <br />LLaY <br />a <br />C6 <br />J LL LL a 5 <br />� <br />Z <br />ZZz 0 <br />N <br />L g 0 Lu <br />Nm a' 0 J <br />0 <br />5 <br />L) <br />= <br />UmW <br />z12¢ <br />0a0 ,_jLOus <br />= <br />p <br />U <br />N <br />z_ <br />z � <br />� <br />z � <br />$ <br />C� <br />Q <br />V) <br />Z vC1 <br />0 <br />W <br />�O <br />Cl_ <br />m <br />U <br /><M <br />4_6 <br />C:,w <br />z <br />z <br />(h <br />o <br />a <br />i <br />J <br />IL <br />E E <br />h <br />S <br /><M <br />zy¢o <br />_ <br />S I_ <br />KoK <br />L 0 <br />H <br />aNig <br />�J <br />m <br />r0 <br />L-Y <br />NO <br />0 <br />Z� <br />z <br />YZ <br />� <br />s <br />° <br />aZ <br />W <br />U 3� <br />o <br />� <br />N WY< <br />, <br />IIIIIIIIII� <br />CD <br />W F <br />0 <br />Y� <br />a = <br />US <br />Co <br />2 <br />co <br />0 <br />d' <br />N <br />Co <br />:3 <br />N <br />LO <br />N <br />r— <br />�i <br />07 Y <br />C1 <br />T <br />CO <br />v / m <br />N <br />F— <br />O <br />� <br />N <br />L.n <br />� <br />04 <br />O <br />O <br />r <br />(a <br />(O <br />M <br />Z <br />T <br />B <br />m <br />a <br />� <br />0 _j <br />Q a <br />JOB <br />NO: 22-01714-01709 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />9 <br />