i t rlri�_ �rl�"✓Q�I�'r��� I� � Q i I' Y' I"' iIH"IA'I�1�1' ' I I <br />R <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:-) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />DOUBLE JOIST CONSTRUCTION <br />(Not required If both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />r <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />16GAx1-1/2" LONG (3/4%1" 2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />CROWN) STAPLES @ 6" OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) DOUBLE JOIST CONNECTION <br />N.T.S. <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF I �� <br />HOME H C G <br />GARAGE SIDE O 0 0 <br />5'-0" <br />STUB -OUT FOR 0 1'-O" o o ;n <br />GAS METER <br />e U <br />fV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-311 <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-111 <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />151-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />*TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />1l <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood Panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />w panels <br />2 x _ + 5/8" or 3/4" wood panel <br />2.0 <br />L!O <br />2x _ lumber <br />Double 2 x _ lumber <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pif max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />atbearing. <br />Squash block / <br />(2x4 minimum) �I <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Itse 3" (ind) nails at R" nr <br />°i Provide adequate bearing <br />for each lapped joist. <br />10dnaifs SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D NO EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />FILL CELL <br />w <br />CONT. #5 STD. 90" <br />HOOK <br />BAR <br />STD. 900 HOOK <br />BOND BEAM <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. GIRDER TRUSS <br />CONT. #5 <br />BAR 2X TOP PLATE <br />-- 5/8"0 <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />-� BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />r� <br />�PLYW000 FLOOR <br />CONT. BASE PLATE <br />BEARING COLUMN �" i/ "..r ,J. <br />SEE PLAN FOR REQ'D I %�— <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION J, <br />�. YJ L• TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />L Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" max. 4' max. <br />Web Stiffener Fastener Schedule <br />r Joist Bearing Location <br />Series Depth End I Intermedfa_te <br />BCI 5000s(5 11-7 18" 2 8d 3-8d <br />A —14" 2-8d 3-Bd <br />Clinch nails 9-1/2" 2-8d 2-8d <br />when BCI 6000s® 11-7/8" 2-8d , 3-8d 1 <br />possible iBCI6500s® 14" 2-8d 5-8d <br />16"2-8d 6-8d. <br />11-7/8" 2-8d 3-8d <br />Tight ._._.. r1 BCI60s®j 14" 2-8d 5-8d __- <br />9 1.61' 2-8d 6-8d_ <br />2x4/PI OSB web stiffener \ 2" min. <br />® 1�1-7/8" 3-16d 3-16d <br />ytrvood/ BC190s 14" 5-16d 5-16d _J <br />required when indicated or 4" max. 16" 6-16d 6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pif max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />�— blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel "Non -stacking walls <br />require additional consideration. — <br />rl <br />6� A 1Y" ROUND HOLE MAY 6" 6" <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y2" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE, THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2' ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. <br />Plumbing <br />Joist <br />I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />-� 1/4"1 gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"1 gap at top of bottom 1/4"1 gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />p r <br />0.6 X Joist <br />✓ " ^ depth <br />1- . I <br />I -JOISTS BUCKETS <br />N.T.S. <br />LC <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEMS <br />SEE PLAN FOR----'•• a . • <br />FOUNDATION INFO ` d <br />STEM FOUNDATION <br />REINF. SEE PLAN <br />(2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A J. <br />° (WHEN <br />w/ (18) 10d x 1 1/2" = REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />ntnr I irr►-rl^ w i -rll 1r 1 1 rk 1r% <br />PVC OR SCH40 SLEEVE <br />TOP (2) #5's x 4'-0" <br />CENTERED @PIPE PLUMBING LINE <br />PENETRATION <br />d a <br />�. d <br />d A <br />SEE FND. PLN. <br />SIZE & REINF. <br />01 <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 C .d A, d d0 L <br />c 4 <br />4. <br />Tr -1 I <br />SEE FND. PLN. <br />SIZE & REINF. <br />-a <br />cJ C� � n <br />�•+ '5 <br />N i. t•) <br />e" 7 <br />O (1. <br />V, d <br />C) <br />a - <br />.> rp N <br />4 '.t <br />T. <br />r c <br />ro ,� O O <br />`� 0 W <br />CL <br />0 <br />N <br />0 <br />`` `�gOEtt.tlJ <br />LE <br />• <br />= No P,?$750• <br />r <br />r' n••• TA 1 E OF <br />. is <br />r'�A l'`Y,:1-� <br />�'oJ%srltt++^+tip <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />0 .9 <br />8 <br />pp <br />N # lJL <br />0 <br />,n LL W <br />�U_li a <br />_9 0o <br />Z t m � o <br />9��<; 2 J <br />II% O <br />WpjO' a <br />d a <br />Z & 0 cQ y 0 <br />ZN OU fJ <br />W ❑0O <br />0 <br />z_ <br />2—!10 <br />z <br />- N <br />z <br />V)-9 <br />U o <br />, V W <br />U � <br />V) lmv <br />+n = '3 <br />�c <br />w -9 e <br />� 8 <br />i <br />_ <br />U <br />c Y <br />0 <br />Q <br />C'7 <br />w <br />E <br />z • <br />Q <br />pp <br />E <br />IT <br />x° <br />Z- <br />S E <br />_ <br />3= <br />0� <br />wz <br />N it <br />g <br />�� <br />Z� <br />v7 J <br />WYg <br />W. <br />�a <br />2 <br />W <br />O <br />ON <br />ap= <br />U 3 <br />°O <br />> co <br />rn <br />m <br />_ <br />1414- <br />N <br />T <br />N <br />' <br />Cr <br />�O <br />60 <br />U) m <br />N <br />i-- <br />O <br />N <br />O <br />QQ <br />0) <br />CO <br />T <br />N <br />T Cr1 <br />U5 <br />r— <br />Zo <br />Z <br />E T N <br />`m <br />c <br />m <br />a <br />F <br />US u� <br />a o <br />JOB <br />NO : 22-01714-01709 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />