Laserfiche WebLink
FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />WEATHER RESISTIVE <br />BARRIER <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />TEMPORARILY SECURE <br />WEATHER <br />DOOR ROUGH OPENING <br />� SLOPE <br />RESISITIVE <br />0.3 in : 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />BARRIER <br />^ <br />TAPE EXTERIOR <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN 3/4"-1" BEAD OF CONSTR. <br />(0.6 cm: 30.5 cm) <br />include flashing as described in Section R703.4. <br />- 3 SHEATHING <br />BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />SELF -ADHERED FLASHING <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND <br />WALL BY 6 IN. RETURN UP JAMB 6". USE LIQUID <br />EXTERIOR <br />R703.1 .1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />(A66E1°BLED NANDOWr <br />z <br />NAIL BRAND OR EQUAL WEATHER <br />CEMT. FIN. <br />within the wall assembly by providing awater-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />�- <br />© PROOF CAULKING <br />draining to the exterior water that penetrates the exterior cladding. <br />WEATHER <br />� <br />SELF -ADHERED FLASHING <br />BUILDING PAPER <br />RESISITIVE <br />s BARRIER <br />SEAL TOPS OF JOISTS <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />1 <br />DECKING <br />UNDER DECKING <br />SUBFLOOR <br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />(SEE DETAIL <br />SELF -ADHERED FLASHING <br />r; <br />with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No. 15 asphalt <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />1. Cut, fold up & temporarily secure weather <br />RIM JOIST <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />THESE DETAILS ARE GENERIC AND <br />resistive barrier above header to allow for <br />flashing installation <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />2. Self -adhered flashing plus head flashing under 1 <br />weather resistive barrier <br />3. Fold barrier back over head <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />BE USED. <br />weather resistive <br />2 <br />flashing and seal with tape <br />2 <br />O2 <br />individual layers shall be installed independently such that each layer provides a separate continuous lane and an flashing installed in <br />Y P Y Y p p P Y 9 <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />Scale: NTS ■ <br />SELF -ADHERED FLASHING <br />FLANGED WINDOW 1 <br />SELF -ADHERED FLASHING ■ <br />1 <br />SELF -ADHERED FLASHING ■ <br />1 <br />Exception: Where the barrier that is has <br />EXTERIOR DOOR WITH DECK - SECTION A <br />CEMT. FINISH SILU POTSHELF/CHIMNEY SHOULDER <br />water -resistive applied over wood -based sheathing a water resistance <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />substantially nonwater-absorbing layer or designed drainage space. <br />EXTERIOR SHEATHING <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />RUBBERIZED <br />EXTERIOR SHEATHING -� <br />3/4"-1" BEAD OF CONSTR. INSTALL SELF -ADHERED <br />ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />NEEDED IN CORNERS <br />ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be applied <br />3/8" CEMENT <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE <br />FLASHING SELF -ADHERED FLASHING <br />shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />g g pp <br />PLASTER <br />12 MIL DRYLOK CMU - MASONRY BLOCK <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WII <br />used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />EXTREME <br />REFER TO TECHNICAL <br />SCORED <br />entry of water into the wall cavity or penetration of water to the building structural framing components. <br />WINDOW <br />LETTER ON CHEMICAL e e O <br />COMPATIBILITY ° <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />FASTENER <br />1) SEALANT AT <br />SELF -ADHERED FLASHING ° a <br />SELF -ADHERED FLASHING, <br />_ (BEFORE FOLDING. SCORE <br />RELEASE PAPER TO EXPOSE <br />the buildingwall with a sealant complyingwith AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />g p p p <br />4) SEALANT JOINT WINDOW BUCK TO <br />EXTEND A MINIMUM 6" <br />ADHESIVE AS SHOWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />OUTSIDE EDGE OF MASONRY <br />WINDOW BUCK <br />VERTICALLY <br />BOTTOM OF FROM <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />s <br />SEALANT JOINT <br />e <br />THRESHOLD <br />, <br />^ <br />shall be installed at the following locations: <br />5) SEALANT FROM . INSIDE EDGE OF <br />IN <br />s 3 <br />`� r <br />WINDOW FRAME WINDOW BUCK <br />ACROSS WINDOW BUCK <br />oSECTION-A <br />(SEE DETAIL WP02) <br />J <br />AND TO <br />° <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />WINDOW FRAME <br />MASONRY ATTACHED <br />ATTACHED <br />PER CODE <br />° e e e ° SELF -ADHERED FLASHING <br />° <br />O <br />finish or to the water -resistive barrier complyingwith Section 703.2 for subsequent drainage. Mechanically attached flexible flashin s <br />q g Y 9 <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />6) TOOLED SEALANT xr REQUIREMENTS <br />e <br />BEAD BRIDGING <br />e <br />2 <br />following: <br />° 2 <br />CLADDING AND WINDOW <br />FRAME <br />SELF -ADHERED FLASHING <br />5 <br />1.1 The fenestration manufacturers installation and flashing instructions, or for applications not addressed in the fenestration <br />3) SEALANT WINDOW FRAME T <br />WINDOW BUCK ALL THE WAY <br />NAILING FLANGE <br />1 <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing Instructions or details are <br />9 g <br />AROUND, INCLUDING SILL. <br />2 <br />SEAL TOPS OF JOISTS 1 <br />6 <br />not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />DO NOT FLASH OVER <br />DECKING <br />BOTTOM NAILING p <br />O <br />UNDER <br />WP07) 2 <br />7 <br />drainage. Openings usin an flashing shall incorporate flashing or protection at the head and sides. <br />g9 p g P 9 <br />FLANGE <br />(SEE DETAIL <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3 1.3. In accordance with other approved methods. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />SELF -ADHERED FLASHING <br />■ 1 <br />SELF -ADHERED FLASHING <br />■ 1 <br />SELF -ADHERED FLASHING ■' <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAANDMA 400. <br />FENESTRATION INSTALLATION AND INTERFACE <br />HALF ROUND WINDOW <br />EXTERIOR DOOR WITH DECK <br />INSIDE CORNER <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />SHEATHING <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />- - -- <br />1 <br />6.6.At wall and roof intersections. <br />UP <br />Water Resistant Barrier <br />7.7.At built-in gutters. <br />JAMB, SILL AND HEAD DETAIL <br />Lath <br />APPROVED <br />SELF -ADHERED FLASHING <br />Sheathing <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />APPROVED HOU EWRAP <br />PATCH <br />STRUCTALATH TWIN TRACK 2.5 <br />= Stucco <br />FLASHINGAND WATERPROOFING METHODS TO BE USED. <br />3/4" CEMENT PLASTER l= <br />° n <br />AN <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />DOUBLE <br />Q Q <br />7/8" Cement Plaster <br />"V" SEALANT SOCKET WITH <br />� JOIST <br />°° ° ^ <br />TOOLED APPROVED SEALANT <br />SINGLE WOOD BEAM <br />° <br />Foundation Wall ^ <br />„ <br />in accordance with 7/8 Cement Plaster <br />JOIST BELOW <br />1SELF-ADHERED FLA <br />FLASHING <br />° <br />ASTMC926 in accordance with <br />SELF -ADHERED FLASHING 1 <br />° 4 <br />° ° n <br />ASTMC926 <br />2 <br />° <br />Felt backed metal <br />° <br />lathe in accordance Felt backed metal <br />SELF -ADHERED SELF -ADHERED <br />3" MIN <br />4 <br />k: .'' <br />a with ASTMC1063 lathe in accordance <br />FLASHING FLASHING Q <br />5 <br />with ASTMC1063 <br />,', Building Paper <br />' ' Building Paper <br />7/16" O.S.B. <br />sheathing 7/16" O.S.B. <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING ■ <br />, <br />SELF -ADHERED FLASHING ■ e <br />, <br />■ • <br />FOUNDATION WEEP SCREED , <br />Metal sheathing <br />EXTRUDED SHOULDER <br />DECK JOIST <br />OUTSIDE CORNER <br />Flashing <br />Weep Screed <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL <br />- - - - - - 7 <br />II <br />Installed As Per <br />Manufact. Specs. <br />PRODUCTS DETAILS <br />TILE FINISH <br />I� STRIP OF SAF LEGEND <br />I SELF ADHERED FLASHING (SAF) - <br />Maintain Stampede or similar <br />Bottom of bottom <br />DRAINAGE PLANE WRB DRAINAGE PLANE (DP) WEATHER RESISTANT <br />I r <br />cauk <br />Weep Screed joint only <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />.. <br />1/2 DUROCK <br />W <br />� <br />BARRIER (WRB) - - - - <br />I I BOND BREAK WRB BOND BREAK WEATHER RESISTANT BARRIER- - - <br />II SELF FURRING (SF) LATH M-v� <br />1 1/2" t0 2" <br />Above Roof Weep Screed <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />co <br />I I z I PLASTER ACCESSORY <br />' ' <br />Sheathing Installed As Per <br />I SF LATH SHEATHING, OSB, PLYWOOD, DENSGLASS RSVP«V <br />Manufact. Specs. <br />1'-4" PER PLAN <br />Detail Instructions <br />Refer to the number marked as O in each detail that corresponds to the <br />1'-0" PER PLAN <br />I WRAP DP WRB ONTO <br />I I II THE VERTICAL <br />I I <br />1/2" Cementitious <br />Cement Plaster <br />SURFACE TO TOP OF <br />Decorative Finish <br />numbered items in the list of instructions below: <br />1� <br />I l S I FLANGE AS AN AIR <br />in accordance <br />I I I BARRIER <br />with ASTMC926 o•4 °•o, All inside and <br />1. Install self -adhered flashing in order as shown by numbers <br />SLOPE <br />8°CMU _ <br />\� I I� f 3-1/2"INCH FLANGE <br />I I <br />over wood 2nd °'' _•o,• outside comer will <br />floor ,o•. <br />' °•g,o• <br />2. Install flashing and weather resistive barrier to form water shedding <br />need to be miter <br />laps <br />�� ^ <br />4"OR8"CMU °a - <br />° ° <br />____J z <br />------------- I <br />•� cut and caulked all <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) ° <br />_ _ <br />Z <br />Z <br />I I STRUCTURAL FRAMING <br />r <br />''. •°• ,o, •o, • •, butt joints need to <br />• <br />4. Split the release paper using the ripcord (Split release on demand, <br />�--° ° - <br />FILL WITH GROUT l r <br />g <br />g <br />I_ � <br />- If <br />• o. .o • becaulked using <br />•' o <br />embedded in the adhesive layer) - for ease of installation and to <br />'''r -___ _ -�* STRUCTURAL SHEATHING <br />THIS GAP IS A RESULT OF <br />Stampede or sim. <br />minimize scoring cuts <br />4 ° ° - <br />a <br />CL <br />PLASTER STOP NATURAL SHRINKAGE. 4 STRIP OF SAF <br />caulk for all <br />5. Remove all release paper per standard installation instructions and <br />- ° <br />° ° ° <br />�- - - - - - - - - - DO NOT SEAL. <br />CONTINUOUS BACKER i' ---' ---- DRAINAGE PLANE WRB <br />adhere to substrate using a square piece of flashing material (6" X 6" <br />U <br />ROD & SEALANT DRIP SCREED PLASTIC i I <br />Minimum) <br />SLOPED MUD BED I I ° ° <br />_ <br />uJ <br />ACCESSORY Ii I BOND BREAK WRB <br />6. Fold as shown by arrows <br />^ <br />w <br />I SF LATH <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />.I ° <br />o <br />\ <br />fit tight to corner <br />a - <br />VINYL SHOWER PAN � ^ -. a ° <br />0 <br />A i <br />Note: <br />8. Mechanically fasten as necessary <br />Q <br />° <br />- <br />i <br />The building paper and metal lath must be <br />° ° <br />SLOPE -- ^ <br />- <br />° <br />I i <br />Cement installed over the top of the weep screed. <br />a ° ° <br />___ __________ <br />PLASTER STOP r <br />Plaster <br />cJ <br />A <br />CONTINUO° US BACKER ROD <br />over block <br />t1 <br />v <br />& SEALANT <br />1 st floor <br />a <br />CEMENTITIOUS FINISH <br />WEEP SCREED DETAIL <br />SHOWER SEAT <br />■ <br />■ <br />SOFFIT/CANTILEVER <br />SCALE: NOT TO SCALE <br />77 <br />C" <br />© <br />0 :f <br />G C(, <br />0 <br />ev c <br />0 0 <br />oW <br />j CL ,•- <br />N <br />CZ> <br />CV <br />0 <br />C <br />.% P. LE v -k• <br />•04 <br />.`�O� '•GENS' '''• <br />(V0 50 <br />r <br />STATE OF '•�= <br />• L, w <br />7!p!!Eili9-�` <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />a o -,g <br />N CA LL <br />DO n LL. W <br />a <br />rn M y LL a Y <br />JLLIL�'La�E <br />Z <br />m O I- <br />{'p (p O J <br />N m <br />W °' d Q <br />Z inm Z -J N O <br />IL o. <br />ODU-rrn <br />Z <br />O1171 <br />8 <br />z o� <br />Q v <br />J- <br />n_ <br />V) z.g <br />� N � <br />'U 0 <br />O r.0 <br />LLJ <br />U <br />� <br />0 <br />c <br />Q N W <br />8 <br />sLL <br />a I� <br />=® <br />Qrc <br />(�O Ov <br />~ <br />o <br />w� <br />C <br />g� <br />Z <br />g <br />Z <br />3 <br />Z_ <br />W) <br />a <br />�W <br />6 <br />J <br />C:) <br />° <br />fop <br />V <br />zl�d <br />a <br />ov 3 <br />0 <br />.20 <br />CD <br />e <br />04 <br />LO <br />N <br />T <br />C <br />'^ <br />W <br />60 <br />(n m <br />N <br />i- <br />O <br />c^o <br />y--' <br />N <br />11.11) <br />0 <br />M <br />T <br />Lo <br />to <br />,- <br />ci <br />m <br />{ �M <br />(0 <br />o <br />Z <br />Z <br />i/i <br />E <br />E :> <br />c <br />a <br />U Z <br />JOB <br />NO: 22-01714-01709 <br />SCALE : AS NOTED <br />SHEET NO. <br />