Laserfiche WebLink
3 <br />•v, <br />J <br />CO <br />M <br />to <br />O <br />t" <br />5 <br />CM <br />0 <br />I <br />N <br />Q <br />co <br />M <br />to <br />trn <br />;v <br />v <br />C <br />cn <br />c <br />J <br />c <br />N <br />O <br />I <br />N <br />t[ <br />to <br />Cr <br />0 <br />Q <br />M <br />O <br />a <br />N <br />E <br />s <br />0 <br />0 <br />v <br />v <br />Eff <br />N <br />0 <br />M <br />0 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />UNDERGROUND IDIs <br />SERVICE BY POWER CO.---__ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17.250.94 <br />150A/200A INDOOR <br />PANEL CENTER <br />to lights & outlets <br />to appliances and GFI <br />to WH <br />D Range <br />D HVAC <br />150=2/0 <br />200=4/0 in 2" Conduit <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />PE5G. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF-SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHI <br />CHIMES (OPTIONAL) <br />1-9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />a <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />owl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C. J <br />ROUGH -IN FOR OPT. CEILING FAN <br />� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />CG J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />r- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />IN ATTIC SPACE <br />I SWITCH & LIGH1 <br />I <br />I <br />I <br />1 <br />I <br />BEDROOM 5 <br />1 <br />\ <br />\ /% ROUGH -IN FOR <br />\\ OPT. CLG. FAN/ <br />X., LIGHT PRE-WIRE1 <br />\\\ 6/ <br />\ <br />\ I <br />S.D. <br />I <br />I <br />I <br />BEDROOM 4 <br />1 <br />-; -- - \ ROUGH -IN FOR <br />; <br />\\ � OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />\ 1 <br />I <br />/ S.D. <br />2 <br />,I '�\\\ BELOW <br />� <br />— — — — — — — — — — — — S.D. <br />/ ---- // ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />---7— /// LIGHT PRE -WIRE / <br />-- / --- — I A// <br />ROUGH -IN FOR LOFT <br />OPT. CLG. FAN/ / _ _ _ _1 I / // <br />LIGH(T�PRE-WIIRI�/ I <br />\' 121 <br />61 <br />C.0 . <br />BEDROOM 6 <br />I <br />I <br />I <br />1 <br />I <br />I <br />1 <br />I I <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4'=1'-0" <br />0 <br />0 <br />a>' <br />CD <br />� <br />ti g g <br />CL <br />-to <br />_.cc V � <br />La - <br />cc ® i <br />W % G <br />•a>i :v <br />15 <br />i c <br />ad sa <br />fA tZ � <br />c E ' <br />Es, <br />M <br />CV <br />0 <br />N <br />v- <br />��tiApa <br />.IV <br />ati <br />lJ <br />��J s cif <br />i'JO7870 <br />L r, <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />Q <br />v E 501 N <br />0 <br />8 <br />Noo <br />0 <br />� � 00 <br />oo to # u- <br />N <br />terra L Lu <br />N <br />Q <br />�o a. a <br />wa <br />JLLu- (0 0 <br />Z <br />,n <br />13 <br />0 <br />Z <br />L N V he <br />c � <br />w"o LU 0 <br />U) T - ¢ z <br />W <br />I= <br />z <br />LL <br />IL <br />o.W <br />to M Z U O <br />1=— <br />Z <br />N O <br />0 0 <br />N <br />� <br />r <br />V) <br />cNi <br />co <br />� <br />� o <br />-J <br />cr9 <br />w <br />Uco <br />N <br />LU <br />w <br />�N <br />l�l <br />i <br />ERif= <br />o <br />rn Q5 <br />® 0 <br />o <br />M <br />o' <br />w <br />z <br />4 <br />r.l.- <br />co E <br />Z O <br />oo <br />> M <br />¢� <br />E 0 <br />E: U <br />z <br />H rt) <br />mo <br />�o <br />O <br />a E <br />G <br />p K <br />CD¢o <br />C. t <br />az <br />o <br />�z <br />wz <br />in <br />O C: <br />zz <br />oU <br />mo <br />m J <br />¢a <br />0< <br />z z <br />z <br />Jo <br />T 3 <br />o< <br />az <br />NF <br />m <br />QO <br />F~ <br />Mill <br />M <br />N <br />a ti <br />Cc) <br />•0 <br />i <br />LO <br />L <br />rn <br />Q <br />00 <br />co <br />0 <br />c <br />j <br />V) <br />� <br />T <br />� <br />r <br />/ <br />m <br />— <br />L i <br />1 <br />r <br /><C <br />O <br />M <br />I <br />M N <br />O <br />MN <br />LO <br />M <br />It r <br />r <br />cD Y C <br />i1i <br />E <br />c <br />o <br />Z <br />m <br />Z <br />E O <br />N <br />E <br />U 0 <br />c <br />a <br />¢ p <br />-°tJ <br />JOB <br />NO: <br />23-02469 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.2 <br />