My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36518 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36518 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:26:20 PM
Creation date
2/19/2025 7:59:06 AM
Metadata
Fields
Template:
Building Plans
Street #
36518
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPACED <br />�U <br />�*DIAGONAL <br />AT15'-O"O.C.MAX <br />SEE ROOF <br />PROVIDE 2X4 MIN. BLOCKING AT <br />PLAN SHEATHING <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />BLOCKING <br />END TO TRUSS TOP CHORD <br />TYP. <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />TRUSS <br />A <br />SECT. A -A <br />A <br />G.T. <br />CONTINUOUS LATERAL <br />ADD 2X4 ALONGSIDE <br />BRACING- NAIL OVER <br />TOP CHORD WHEN REQ'D <br />X-BRACE AS SHOWN- <br />TO PREVENT PLYWOOD <br />INSTALL BLKG. AT TRUSS <br />X-BRACING - 2x4 SPF OR <br />SPAN FROM EXCEEDING <br />A CM <br />WEBS FOR NAILING <br />SYP w/ 2-16d @ EACH TRUSS <br />MAX 24" SPAN (EITHER <br />USSES <br />HIP <br />WEB <br />SIDE OR BOTH IF REQ'D) <br />G.T <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = V-0" <br />TRUSS NOTES. <br />CONY. FRAMED RIDGE <br />1. <br />WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 <br />MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2, <br />ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. <br />ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />CB <br />4. <br />ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />(2) 12D NAILS l <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL r2 <br />SCALE: 1/2"=V-0" <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLKING. NAILED @ EACH <br />SIDE w/ (3) 12d NAILS WHEN <br />REQUIRED w/ (2) SIMPSON HTS20 <br />W/ (14) - 10d X 1 1/2" EACH <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT -TB <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg g <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />MAX &EACH END ALTERNATE BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP - <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1 /2"= V-0" <br />2 x P.T. BLOCKING BY FRAMER FOR <br />PLYWOOD EDGE NAILING w/ (2) 1/4"x3" TITEN2 <br />DIAGONAL - <br />AT T-0" <br />MAX <br />TRUSS <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR SIMPSON H2.5A <br />W/ (10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR SIMPSON H2.5A @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />- - COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT-/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A —A ALTERNATE BLOCKING <br />DETAIL a� INTERIOR BEARING 3 <br />SCALE: 1/2" = V-0" <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />PROVIDE 25" LAP <br />(2) SIMPSON SDWC15600 SCREWS @ W SPLICE @ F.C. REBAR <br />EACH TRUSS TO LEDGER <br />1/2" GYP. WB OR 3/8" PLYWOOD/ TYPE <br />2-M-W OSB (DRAFTSTOPPING) TO BE <br />• ••- - •- • ■ <br />- <br />9� <br />- ••. - <br />alai <br />24" O.C. STAGGERED @ <br />12" O.C. <br />DOUBLE KNOCK -OUT - <br />BLOCK w/ (1) #5 CONT. <br />IN EACH COURSE. <br />� FLOOR CONNECTION @EXTERIOR WALL <br />SCALE: 3/4" = V-0" <br />2'-0" MIN. <br />01 <br />LAP SPLICE <br />1'-0" 6" 6" 1'-0" 6" 6" 1'-0" <br />TYP. TYP. <br />L� 0 0 1 0 0 0 07 1 <br />I SPLICE <br />0 0 I 0 O 0 0 <br />2.0 SPLICE BEYOND 2'-0" <br />PART. ELEV. VIEW <br />1 All n r <br />b <br />DBL. KO. BLOCK MIN. <br />b <br />MIN. TYP. <br />a <br />a <br />o <br />24" MIN. <br />(2) 2x8 P.T. <br />ATTACHED <br />(2) 2x8 SYP #2 P.T. CONT. <br />LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" <br />O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE & <br />EACH END. <br />LEDGER <br />LAP SPLICE TOGETHER w/ <br />PART. PLAN VIEW (2) ROWS OF 10d @ 6" O.C. <br />LEDGER SPLICE DETAIL 54 <br />SCALE: 3/4" = V-0" <br />- PROVIDE 30" LAP SPLICE <br />@ F.C. REBAR. <br />(2) ROWS OF 10d NAILS @ 4" O.C. <br />MASONRY <br />FLOOR TRUSSES SEE PLAN <br />@ 24" O.C. <br />I�SI <br />DOUBLE KNOCK -OUT <br />BLOCK W/ (1) #5 ALTERNATE: <br />CONT. IN EACH (2)2x8 SYP #2 P.T. <br />COURSE LEDGER ATTACHED TO MASONRY W/ <br />(2) 5/8" DIA. TITEN HD MIN. 5" <br />EMBEDMENT PER 54/D1 SPACING <br />SIMPSON HGAM10 @ <br />4'-0" O.C. T & B <br />FLOOR ATTACHMENT('5�0 <br />SCALE: 3/4" = V-0" <br />WOOD <br />OPTIONAL 6" WIDE BOARD <br />BATTEN STRIPS TO <br />ELIMINATE 3/4" AIR SPACE. <br />SEE MANUFACT. SPECS. <br />FOR INSTALLATION.—-,, <br />PRE-ENGINEERED ROOF --� <br />TRUSSES AT 24" O.C. MAX <br />(2) LAYERS 1"x24" PROPRIETARY TYPE <br />"X" GYP. PANELS INSERTED BETWEEN <br />2" FLOOR & CLG. RUNNERS W/ 2" <br />STEEL H STUDS BETWEEN ADJACENT <br />PAIRS OF GYP. PANELS. <br />2" FLOOR RUNNER <br />W/ 3/16" DIA. x 1 3/4" <br />TITEN2 @ 16" O.C. <br />FIRE CAULK <br />RUNNER TO BLOCK <br />WALL EACH SIDE <br />NOTES: <br />1. SEPARATION WALL IN THE <br />ROOF SYSTEM PROVIDES <br />2-HRS. PROTECTION PER <br />GA FILE ASW 1002. <br />6" WIDE 1/2" DENSARMOR PLUS FIREGUARD-C OR <br />TOUGHROCK FIREGUARD-C GYPSUM BOARD <br />DETAIL - ADJACENT TO TRUSSES <br />GA FILE ASW 0810 SCALE: 3/4"=1 <br />2x4 BLOCKING @ 48" O.C. MAX. W/ <br />(2) 16d TOE NAILS @ EACH END <br />2" CLG. RUNNER FIRE CAULK <br />\ RUNNER TO SHEATHING <br />ABOVE AT EACH SIDE-7 <br />STD 909 HOOK <br />2. MASONRY WALL PROVIDES (1) #5 VERT. IN FILL CELLS <br />2-HRS PROTECTION PER (SEE FILL CELL PLAN FOR <br />UL-U905 (see sht 9) LOCATIONS) <br />2 x P.T. BLOCKING BY FRAMER FOR PLYWOOD EDGE NAILING <br />W/ (2) 1 /4"x3" TITEN2 <br />(2) SIMPSON SDWC15600 SCREWS @ EACH <br />TRUSS TO LEDGER <br />(2) 2x8 SYP #2 P.T. CONT. LEDGER w/ (2) ROWS OF 5/8" <br />TITEN HD STAGGERED @ 24" O.C. w/ 5" EMBEDMENT & 6" <br />EACH SIDE OF SPLICE AND EACH END SEE 54/D1 <br />3/4" PLYWOOD DECKING GLUED AND <br />NAILED W/ 8d COMMON AT 6" O.C. <br />EDGES AND 12" O.C. FIELD <br />1/2" GYP. WB. OR 3/8" PLYWOOD/TYP 2-M-W <br />OSB (DRAFTSTOPPING) TO BE NAILED W/ <br />8d COMMON AT 6" O.C. TO ONE SIDE OF kP CH I <br />FLOOR TRUSS FOR AN AREA < 1000 S.F. 0 TEI <br />AND SEALED PENETRATION AREAS W/ <br />FOAM. DRAFTSTOPPING SHALL DIVIDE <br />THE CONCEALED SPACE INTO APPROX. <br />EQUALAREAS <br />(1) LAYER 1/2" HIGH STRENGTH OR 5/8' GYP.-/ <br />(OR 5/8" GYP. TYPE "X" @ GARAGE W/ A <br />HABITABLE ROOM ABOVE) W/ 1 3/8" <br />DRYWALL NAILS OR DRYWALL SCREWS 7" <br />O.C. CEILING, 8" O.C. WALLS & 4" O.C. <br />EDGES <br />(1) #5 VERT. IN FILL CELLS (SEE — <br />FOUNDATION PLAN FOR LOCATIONS) <br />8" CONC. BLOCK (TYP.) PER UL905 - <br />1x P.T. BASE NAILER <br />6x6 W1.4xW1.4 WWF. —� <br />w <br />v <br />J <br />a <br />U) <br />/7\.10A Tn C:KlAILS <br />2X6 P.T. CONT. <br />-EDGER T&B W/ (2) <br />1/4" X 3" TITEN2 @ 24" <br />D.C. T&B <br />TRUSS <br />(6) .162" x 3 1/2" NAILS <br />TRUSS TO LEDGER & <br />(4) .148" x 1 1/2" <br />LEDGER DETAIL <br />SCALE: 3/4" = V-0" <br />NO MINIMUM AIR SPACE <br />W/ BATTEN STRIPS <br />1" DENSGLASS ULTRA <br />SHAFT LINER <br />MASONRY WALL <br />SEE FLOOR <br />PLAN FOR MORE <br />INFO, <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />_ VARIES W/ <br />ROOF SLOPE <br />MIN. 2X4 #2 SPF P.T. <br />CONT. W/ (2) a'x3" <br />TITEN2 SCREWS @ <br />16" O.C. <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALLK52 <br />SCALE: 3/4" = V-0" <br />PROVIDE 2x BLOCKING W/ (2) 12d NAILS EA. END BETWEEN <br />TRUSSES 4'-0" FROM SEPARATION WALL. SOLID BLOCKING <br />12 BETWEEN TRUSSES TO BOTTOM SIDE OF PLYWOOD. BLOCK <br />SEE MUST BE "PITCH CUT" (SEE ELEVATIONS) TO PROVIDE AS <br />ELEV. MUCH CONTACT AS POSSIBLE TO UNDER SIDE OF ROOF <br />DECK. ALL JOINTS AROUND BLOCKING MUST BE CAULKED <br />WITH APPROVED FIRE CAULKING. <br />0 LB FELT (SHINGLES) <br />FIRE RESISTANT OSB 7/16" <br />SHEATHING 4' ON EA. SIDE <br />OF WALL NOT STAGGERED CEILING BOARD <br />OVER PARTY WALL <br />2x4 LEDGER @ 48" O.C. SEE ROOF PLAN <br />MAX VERTICALLY NAILED FOR STRAP INFO. <br />TO TRUSS WEBS W/ (2) 8d BASE BOARD PER SPECS. <br />(TYP.) <br />EXTEND BURN CLIPS AS PER 2 x P.T. BLOCKING BY FRAMER <br />FIRE WALL MFG. FOR PLYWOOD EDGE NAILING <br />R30 INSUL. MIN. SPECIFICATIONS NAILED INTO W/ (2) 1/4"x3" TITEN2 <br />2X4 LEDGER ONLY AT EACH <br />SIDE OF STEEL "H" STUD. <br />(2) SIMPSON SDWC15600 <br />(1) LAYER 1/2" HIGH STRENGTH SCREWS @ EACH TRUSS TO <br />OR 5/8" GYP. WB. W/ 1 3/8" LEDGER <br />DRYWALL NAILS OR DRYWALL <br />SCREWS 7" O.C. EDGES. <br />,\\—SIMPSON RBC @ 36" O.C. W/(6) 10d X 1 1/2" NAILS 3/4" FLOOR <br />INTO TRUSS BOTTOM CHORD/SCAB & (3) 1/4" X 2-3/4" SHEATHING <br />TITEN SCREWS INTO MASONRY. NOTE: RBC CLIPS <br />TO BE INSTALLED PRIOR TO FURRING STRIPS <br />INSTALLATION (TYP. ON BOTH FACES OF WALL) <br />1x P.T. NAILER INSTALLED <br />AFTER INSTALLING RBC'S 1/2" GYP. WB OR 3/8" <br />8"x8"x16" CONC. KNOCKOUT PLYWOOD/ <br />BLK. W/ 1 #5 ROD CONT. TYPE 2-M-W OSB <br />FILLED W/ GROUT (DRAFTSTOPPING) <br />4"x4" INSPECTION PORT AT 0 BE NAILED W/8d <br />/—EACH FILLED CELL (TYP.) COMMON @ 6" O/C TO <br />1x P.T. BASE NAILER ONE SIDE OF THE <br />-STD. 90° HOOK FLOOR TRUSS FOR AN AREA <_ 1 <br />(SEE DETAIL) OF <br />NAIL FLOOR TRUSS TO LEDGER W/ FLOOR AREA &SEALED <br />(4) 10d TOENAILS (TYP.) EA. SIDE PENETRATION AREA W/ <br />FOAM. DRAFTSTOPPING <br />SHALL DIVIDE THE <br />(2) SIMPSON SDWC15600 SCREWS @ CONCEALED SPACE INTO <br />EACH TRUSS TO LEDGER APPROX. EQUAL AREAS. <br />TOI' ORD BRG. <br />DOUBLE KNOCKOUT BLOCK W/ (1) #5 ROD <br />CONT. IN EA. COURSE FILLED W/ GROUT <br />1" P.T. NAILER <br />R-3 MIN. INSUL. PER. FBC. <br />1/2" GYP. WB. <br />TYP. "S" MORTAR (TYP.) <br />Z _I <br />�a <br />N <br />4"x4" INSPECTION PORT. AT <br />�/—EACH FILLED CELL (TYP.) <br />0 <br />(4) #5 CONT. STD. 909 HOOK <br />ON 3" CHAIR 8" 2'-0" 8" (SEE DETAIL) <br />10 <br />SCALE: 3/4" = V-0" <br />REV. 05.24.23 <br />PRE-ENGINEERE <br />FLOOR TRUSS' AT <br />24" O.C. <br />GYP. BOARD CLG. <br />SEE 53/D1 FOR <br />LEDGER CONNECTIONS <br />1/2" GYP. BD. <br />(2)-1 X 4 P.T. o ^ <br />NAILER <br />BASE BOAR[ <br />PER SPECS. <br />CONC. SLAB <br />SEE FOUND. <br />6 MIL VISQU <br />TREATED,' <br />SEE PLAN <br />TOP OF PLATE <br />TOP COURSE W/ <br />LINTEL SEE <br />PLAN <br />0 <br />SEE PLAN <br />TOP OF WINDOW <br />WINDOW PER PLAN <br />8" C.M.U. WALL <br />10'-8" <br />_�—DOUBLE KNOCK -OUT <br />W/ (1) #5 CONT. IN. <br />EACH COURSE <br />REINFORCING W/ MATCHING <br />#5 DOWELS IN SOLID <br />GROUTED CELL W/ MIN. 25" <br />LAP SPLICE MIN. <br />8" C.M.U. WALL <br />JH1Ii <br />F.F. <br />oo <br />VARIES WITH <br />b SITE GRADES <br />SEE PLAN <br />CV <br />T <br />3 #5 CONT. 20" <br />TYP. 2 STORY WALL SECTION <br />SCALE: 3/4" = V-0" <br />REV. 08.20.21 <br />N <br />c <br />d -o <br />V C r— <br />�. <br />U - m <br />LA_ <br />,.: = a <br />O N M CQ <br />H -a N s <br />In <br />If <br />Q <br />® <br />cj <br />t` <br />or, <br />. m CD <br />E <br />cM <br />N <br />0 <br />N <br />co <br />N <br />i O <br />1 <br />7, <br />.. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E.4 of $ N <br />O N 8 N v <br />f <br />4 N O° CD: <br />0 � ° <br />7 � N # LL LL <br />s y (nrr-� LL W <br />N a a <br />�cNiv � w <br />.4 <br />cou Z <br />O O <br />�- warn <br />L m V O Y o <br />o o <br />w <br />w co m <br />_� Q <br />W U)�pjO' J G <br />w <br />_• N coZ U O r <br />z <br />❑❑ OU ❑ <br />W <br />� N O <br />0o <br />N <br />� o � <br />� <br />Q v <br />J <br />M <br />Ul) 2!o <br />Q) C 0 <br />U <br />0 �, oW. <br />In c <br />�N <br />a <br />m <br />L.0 <br />E <br />If... <br />o N <br />co 1 <br />Q <br />.16 <br />N <br />I� <br />ti <br />o <br />Jz <br />J <br />M <br />0 ' <br />Z <br />Q <br />Zo <br />ZQ <br />� U� <br />�� <br /><� <br />vs <br />o E <br />o< <br />a <br />0o <br />S< <br />�o <br />wo <br />�z <br />ww <br />� <br />�J <br />ru <br />C <br />� � <br /><o <br />= y <br />ma <br />O ILL <br />Co v <br />J <br />8 <br />�m <br /><w <br />�N <br />Q n <br />Z Z <br />go <br />C> <br />m <br />� <br /><f <br />a <br />�w <br />cc ff <br />_ <br />_� <br />M <br />v <br />oIa <br />a� <br />� 3 <br />o T <br />> 00 <br />Z <br />a; <br />� <br />� <br />C <br />cc <br />L <br />CO 00 <br />00 <br />� <br />T <br />50 <br />C m <br />000 <br />F- <br />0 <br />LO <br />M <br />LO <br />O <br />N <br />LO <br />CO <br />N <br />r <br />c <br />w <br />o <br />z <br />Z <br />� rn <br />E a <br />`m <br />a <br />E a� <br />v _j ¢ o <br />JOB <br />NO : 23-12154-12159 <br />SCALE : AS NOTED <br />SHEET NO. <br />D 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.