My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36535-36547 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36535-36547 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:25:34 PM
Creation date
2/19/2025 7:59:29 AM
Metadata
Fields
Template:
Building Plans
Street #
36535-36547
Location
Garden Wall Way
Contractor
Lennar Homes
Building Plans - Permit #
4154-4263
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DING WHICH TYPE <br />=S ARE ORDERED <br />ID BRG OR TRUSSES <br />a INTO MASONRY) <br />7OR IS TO FOLLOW <br />EET REQUIRED DUE <br />PE OF TRUSSES TO <br />-ED. OTHER D1 <br />SHEET CAN BE IGNORED OR <br />REMOVED. (TRUSS LEDGER IS <br />PRIMARY DESIGN w/ BUCKETS <br />AS THE OPTION) <br />LOW ROOF / FLOOR FRAMING PLAN <br />SCALE: Y4"=V-0" <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1 1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />R73 <br />345 <br />305 <br />8 - 8d x 1 112" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 112" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-1Od <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />112" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />— <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 1061-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />-- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 21/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 112" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 '* <br />1005/915 ** <br />8 -10d x 3" <br />JUS26 <br />1000/1080** <br />-- <br />8-10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />-- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 "" <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />— <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />MGT 3965 3330 j 22 -10d x (1) 5/8" ATR w/ 12" 1 MUGT15 1 4175 1 122-10dx(1)5/8'-ATRw/12" I <br />EMBED w/ SIMPSON "SET" EMBED w/ USP CIA-7000C <br />l EPDXY EPDXY <br />LGT2 14060-M 3770-F13500-M 3240-F <br />LUGT2 13100-M 4520-F 131 00-M <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 1/2" <br />SP1 <br />555 <br />535 <br />10 - 10d <br />SPT22 <br />735 <br />8 - 10d <br />SP2 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />_ <br />HCP2 <br />590 <br />555 <br />12-10d x 1 1/2" <br />HHCP2 <br />680 1 <br />570 1 <br />(20)1 Od x 1-1/2" <br />` MINIMUM 3" MEMBER <br />" REACTIONS ARE FOR ROOF LOADS ONLY <br />DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(A) <br />OR 2 PLY <br />:ARRIER <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5 4' ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />a(2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM SEE SHEET D1 FOR <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. ROOF FRAMING <br />DETAILS <br />ENGINEERED <br />CLADDING W NDFPR PRESSURES AND OSUUCTIIONIS FOR MEAN ALLOWABLE <br />:5 5 ftND <br />RS H <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SQ FEET) (-) VALUE DENOTES SUCTION <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />10 HIP -35.94 -49.57 1 49.57 49.57 <br />GABLE -38.22 -38.22 -60.99 1 -60.99 1 -60.99 78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: %6" EXP. 1 (2%) or 1Y32" EXP. 1 (32/16) <br />TILE: 1Y32" EXP. 1 (33`ts) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1%2", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2'Y2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />HIP ROOF >20 TO 45 DEG. <br />[4:12]-[12:12] <br />a=4ft <br />I <br />ji <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />cV <br />ni <br />p CD <br />N <br />�-V <br />Q CO <br />(a LL <br />'O O <br />C N <br />T O (>3 <br />� Q1 <br />N <br />0_ <br />< O M <br />U N <br />O <br />'> <br />3 ,? <br />ry N Q.0 <br />Cj� <br />— E C <br />(A O O <br />If CU `- <br />O <br />n Lu <br />CV <br />0 <br />CV <br />CD <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />W <br />S <br />E oro <br />o <br />o <br />O N 8 <br />N to Lt; <br />t71 iC W <br />ti JLud <br />rNiv LLaShe <br />0 <br />JLLu_ 0.. W S <br />Z_ <br />2mg 02 <br />O J <br />W <br />a a <br />LL = <br />¢ a <br />N Nz Rtn0 <br />Z <br />OU <br />W <br />z N f7 <br />z <br />Z <br />Q <br />�4 <br />_D <br />ij— <br />O <br />U <br />) v) <br />YZN <br />LU <br />C!�: <br />w <br />� <br />Q � <br />N <br />MQ <br />s�o <br />co <br />co <br />= <br />J <br />E <br />m <br />saS <br />o0 <br />_® <br />� " <br />a <br />Q� <br />s <br />i o <br />20 <br />0 <br />Z <br />C7 <br />N <br />w <br />m� <br />. <br />>z <br />a� <br />2z <br />W <br />di 3 <br />0- <br />` <br />g <br />z <br />w <br />o� <br />m <br />Cfl <br />L <br />CU "t <br />:3 N <br />0 <br />cN <br />co <br />0 <br />CD <br />N <br />� <br />.0 <br />CDL0 <br />N <br />O <br />T <br />O <br />T <br />o <br />E <br />:3Z <br />O <br />Z <br />a <br />E <br />o <br />a o <br />c <br />°] <br />JOB <br />NO: 22-01142-01139 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />
The URL can be used to link to this page
Your browser does not support the video tag.