Laserfiche WebLink
r <br />K <br />4 <br />F_ <br />OWNER'S BATHROOM <br />SCALE: 3/8" =V-0" <br />q <br />CV <br />MIRROR <br />\ <br />1I ' <br />7I j <br />I�IIi.I <br />F- <br />LJi <br />BATHROOM 2 <br />SCALE: 3/8" = 1'-0" <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" <br />3/4" PLYWOOD \ \ <br />DECKING \\ <br />F. FL. <br />18 ----- <br />17 <br />\- l' 16 <br />42" KNEE WALL <br />WITH 1x8 CAP & <br />CASING (AT 2nd <br />FLOOR ONLY) <br />\ <br />14 \\ - <br />-_( 13 \ \ <br />Kip, <br />2x <br />0NT. <br />AND RAIL <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 4 X 25 <br />S.H. <br />13 <br />20 X 38 <br />18 J X 37 <br />S.H. <br />14 <br />20 X 50 <br />184 X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 } X 62 <br />S.H. <br />16 <br />20X72 <br />18JX714 <br />S.H. <br />1H2 <br />271/4X26 <br />26X25J <br />S.H. <br />1113 <br />271/4X38J <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 i <br />26 x 50 <br />S.H. <br />1115 <br />27JX63 <br />26X621/2 <br />S.H. <br />1116 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 501 <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />36JX711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 <br />S.H. <br />33 <br />54 X 381 <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 } X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL <br />r� <br />n <br />i <br />U 1 F. FL. <br />14' 2" 2x4 #2 SYP. P.T. THRUST <br />,00 <br />BLOCK W/(2)-1/4"x 31/2" <br />TAPCONS @ 16"o.c. AND <br />TYP. STAIR SECTION 3" FROM EA. END. <br />SCALE: 1/4" = l'-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34" <br />NOR MORE <br />THAN 38" ABV. <br />TREAD NOSING <br />METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />HANDRAIL DETAIL <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding 'Y2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handralls: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />i• <br />u <br />1ST FLOOR PLAN -UNIT-A 1532 <br />SCALE: V4"=1'-0" <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />M FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />18'-4" <br />T-4" <br />12'-0" 3'-0" <br />1'-4" 1'-8" T-10" <br />5'-0" 3'-10" <br />2'-8" <br />© <br />O <br />MOD <br />25 SH <br />MOD 25 SH <br />( 39" <br />■'' ® <br />x 59") <br />( 39" x 59" ) <br />■ <br />EGRESS EGRESS <br />o <br />°D <br />OWNER'S <br />EO <br />55 <br />BEDROOM <br />D1 - <br />TYP. U.N.O. M�a <br />8'-0" FLAT CLG. <br />® <br />I CARPET <br />4 <br />- <br />I <br />o0 <br />N <br />o? <br />17'-8" <br />io <br />rn <br />64" <br />10 <br />U 4'4" 1# 7'-0" <br />M.C. <br />R&S <br />- <br />-----------1 <br />- O. BATH <br />1 22"x36" <br />8'-0" FLA <br />- CARP <br />Cl ATTIC <br />T ACCESS <br />- 1 <br />(C <br />' <br />00 <br />/ <br />28 \\ 8/FLAT CLG <br />M <br />iv <br />^ <br />N I <br />N ICARPET IT <br />PWOI <br />\/ <br />D 1 <br />L _v_ _J I <br />® <br />- - -_ _ _ I <br />----J <br />TYP. <br />O <br />I <br />2868 <br />R&S <br />iv <br />5 <br />® <br />6 <br />00 <br />7 <br />co <br />vE <br />TO <br />7' A. <br />Co <br />(V <br />60"x <br />AHU <br />10 <br />00 <br />WER PA <br />tD <br />C7 <br />R/A <br />I 11 <br />i <br />11 <br />5ql' <br />4'-4" <br />T-4" <br />- ; <br />1 I 13 <br />LOFT <br />to <br />®' <br />II <br />8'-0" FLAT CLG. 14 <br />o <br />LO <br />-- <br />00 n <br />CARPET 15 <br />50 <br />co <br />N <br />II 1 16 <br />1 <br />I I 17 <br />II UP 1 <br />7' A.F.F. <br />L� <br />0 <br />1/2 WALL <br />I o <br />CAPPED <br />= 6-4 <br />CV <br />1'-10" <br />9'-6" <br />� <br />O <br />N <br />T <br />O <br />1'-0" Cnv <br />2668 <br />N <br />BAT <br />11 <br />8'-0" FLAT <br />CLG <br />M.C. CARPET <br />o <br />01 <br />Will <br />" <br />8%0" FLAT CLG. <br />iv <br />CARPEI-- <br />2668 <br />�r <br />06 I <br />4 <br />iD <br />I <br />Z <br />BEDROOM 2 <br />R&S <br />8'-0" FLAT CLG. <br />CARPET <br />Ta <br />G.T. - - <br />G.T. <br />OP <br />rh <br />© <br />LO <br />- <br />MOD 25 SH <br />(39" x 59") <br />EGRESS <br />T-8" <br />T-10" <br />T-10" <br />4'-0" <br />T-4" <br />01 <br />o <br />ao <br />7'4" <br />11'4° <br />Ll <br />CD <br />LO <br />18'-4" <br />2ND FLOOR PLAN -UNIT-A 1532 <br />SCALE: Ya"=1 '-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />OA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />Q <br />+28.3 / -30.8 <br />0 <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET �H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tal R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />■ From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position, 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />..........■■.■■.......... <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR <br />2ND FLOOR <br />677 S.F. <br />864 S.F. <br />TOTAL <br />1541 S.F. <br />GARAGE <br />246 S.F. <br />LANAI <br />110 S.F. <br />ENTRY <br />42 S.F. <br />TOTAL SQ. FT. <br />1939 S.F. <br />INSULATION REQ. <br />LOCATION I R-VALUE / TYPE <br />R-4.1 HIGH PERM <br />R-11/R-13 KRAFT FACED <br />R-19 KRAFT FACED <br />R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />EXT CONC WALL <br />EXT FRAME 2 x 4 <br />EXT FRAME 2 x 6 <br />CONDITIONED CEILING <br />c� <br />0 l` O <br />c.a <br />Q U N <br />CL CO X <br />N ILL p_ <br />> <br />.ct <br />-0 O <br />1✓ N L <br />V (D O CU <br />C � N <br />va) .- >` <br />QL C- <br />u E t-- Q <br />Q O <br />a) Q <br />- 3 U 0) <br />.-.a �0 <br />> W <br />w Q) Q <br />IY E <br />C: <br />M 0 0 <br />C- C) <br />" ca `� <br />0 <br />N <br />0 <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />Q <br />E co <br />o Nm8 <br />N N 0 LL <br />C <br />ac: <br />rA #LL W <br />GOLo <br />0 <br />di <br />a9 <br />r4. <br />�CN0 wLL Q <br />LL LL � Z�ay W }� <br />= <br />i MQ O <br />$g�� <br />W <br />W <br />ILZ <br />01 m <br />°' rn < <a <br />� 5No <br />Mz <br />p U 5 vvi <br />Z <br />W <br />❑ ❑ ❑ <br />Z' N <br />z <br />z <br />a <br />Q1 <br />2!� 1 <br />(D <br />al <br />"U <br />O <br />to <br />M <br />w 8 <br />c N <br />as <br />LU <br />= J <br />c <br />C� & <br />t9 <br />�n <br />w <br />-.J <br />a E <br />E v0 <br />cv <br />I—9� <br />K <br />0° <br />H <br />z■ <br />an <br />0 <br />U <br />Zi <br />F- <br />@� <br />g <br />5 <br />ffW <br />W <br />Z <br />� <br />ry <br />C <br />�� <br />F$ <br />O8 <br />%2 <br />0 <br />� <br />g <br />az <br />W <br />U <br />$$ <br />°LL <br />J <br />o <br />_S2 <br />w� <br />ooyy <br />2I< <br />Wo <br />U <br />4 r <br />> <br />ii <br />im <br />M <br />_ <br />CV <br />0 <br />� <br />C) <br />� <br />I <br />cN <br />L <br />CU � <br />=) N <br />N <br />`.� <br />00 <br />o <br />in <br />0 <br />N <br />O <br />N <br />C14 <br />O <br />Sao <br />T <br />N <br />LO <br />0 <br />LO <br />0 <br />Z <br />7 O <br />E <br />H <br />to <br />Z <br />`m <br />c <br />ra <br />a- <br />U <br />V - <br />Q p <br />c <br />C <br />� <br />JOB <br />NO : 22-01142-01139 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />