!3 <br />eli <br />ROOF PLAN <br />SCALE: 1 /4"=1'-0" <br />ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />2002 SQ. FT. _f <br />961 SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />384 SQ. IN. <br />UPPER VENT 50% NET VENT MAX. <br />480 SQ. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />3 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />414 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />547 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF. <br />83 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905.1.1 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />���� �P.•�� C E N: <br />• N <br />oll <br />STA E C <br />cc <br />W <br />wz0= <br />O }. F— <br />W�QO <br />p <br />< Z) <br />cr w <br />(L(nW W <br />!r cr IY <br />cn <br />z p <br />z z w <br />W Q � <br />a a <br />_ cc — <br />�(npOU <br />�1zu-u) <br />� F- < z <br />R <br />cz <br />cz <br />n <br />1. <br />Q O <br />O <br />�i <br />IQ- <br />O <br />O <br />O <br />ft <br />U <br />O <br />Z <br />0 <br />(L <br />o <br />� <br />O <br />w <br />O <br />w <br />0� <br />U) <br />w< <br />w <br />w <br />w <br />(n <br />m< I <br />0 <br />E <br />U) <br />W <br />0 <br />U) <br />O� <br />ro <br />cs <br />'F ••tip <br />r <br />OCT 5 2021 <br />`COMMUNITY; <br />LINKS AT AL.0 A <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 10/5/21 <br />SHEET <br />A3. I <br />0 <br />Z <br />w <br />Q <br />0 <br />Z <br />0 <br />ad <br />U) <br />Z <br />w <br />W <br />