My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36813 Yesler Dr
Zephyrhills
>
Building Department
>
Building Plans
>
36813 Yesler Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:46:50 PM
Creation date
2/19/2025 8:00:12 AM
Metadata
Fields
Template:
Building Plans
Street #
36813
Location
Yesler Dr
Contractor
K Hovnanian Co LLC
Building Plans - Permit #
3083
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />0 <br />SEE SOFFIT AT RAKE (BEYOND) <br />)F PLAN REFER TO PLANS <br />FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />- (OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />�Y(REFER TO ELEV.) <br />INSULATION AS I 2X ALUM WRAPPED FASCIA <br />PER SPECS. ----- BD. w/ALUM DRIP EDGE <br />PRE-ENGINEERED SOFFIT INSTALLED PER <br />GABLE END ROOF MANUF. SPECS <br />TRUSS - REFER TO 2X PT BLOCKING <br />STRUCTURALS HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. MASONRY LINTEL -REFER TO <br />STRUCTURALS <br />TYP. HIPPED PENT ROOF DETAIL <br />SCALE: 1/2" = 1'-O" <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />12 <br />R905.1.1.1 (SEE SHEET CS2) <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />PLAN <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OIL TOP OF C.M.U. <br />i <br />(REFER TO ELEV.) <br />INSULATION PER <br />2x6 ALUM WRAPPED FASCIA <br />COMMUNITY SPEC. <br />BD. w/ALUM DRIP EDGE <br />SEE ENERGY CALCS. <br />_EE <br />1/2" (MIN.) CLG. BD. <br />SOFFIT INSTALLED PER <br />ix PT DRAPE BLKG MANUF. SPECS <br />ABOVE WINDOWS 1/2" 2X PT BLOCKING <br />G.W.B. <br />SEE STRUCTURAL <br />WINDOW PER PLAN PLAN <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT PRECAST WIN. SILL <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO 1x2 PT. <br />FURRING @a 24" O.C. SLOPE GRADE AWAY <br />BASE BOARD u FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL P WINDOW <br />SCALE: 1/2" = 1'-O" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />k GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GRADE <br />GYPSUM - <br />GYPSUM <br />BOARD <br />BOARD Z <br />5 <br />3 1/2" a. <br />j" GYPSUA <br />III <br />GARAGE a <br />BOARD <br />NICHE FOI <br />ELECTRIC, <br />PANEL & <br />WIRING <br />cV <br />c4 <br />ELECTRICAL <br />PANEL ELECTRIC, <br />PANEL <br />i <br />N <br />CO <br />EXTERIOR <br />CMU BLOC <br />WALL <br />cV <br />CONCRETE CONCRET <br />CURB REFER CURB REF <br />TO PLANS TO PLANS <br />CONCRETE <br />SLAB ON <br />GRADE AT <br />GARAGE <br />FLOOR <br />1-STORY - MASONRY WALL <br />12 <br />SEE ROOF <br />PLAN <br />1/2" (MIN.) _/ <br />CLG. BD. <br />(t" TYPE 'X' GYP. BD. <br />TO BE PROVIDED <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />,J STRUCTURAL. <br />OIL TOP OF C.M.U. <br />'AF(REFER TO ELEV.) <br />I I <br />2x6 ALUM WRAPPED FASCIA <br />EE �. BD. w/ALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLAB, 4, SPECS DRIVEWAY PER COMMUNITY <br />SEE STRUCTURAL <br />SLOPE SLOPE 0'-0 <br />PLANS .. <br />FIN. FL. <br />`—FOUNDATION <br />M PER STRUCTURAL DRAWINGS <br />WALL SECTION Qr GARAGE DOOR <br />SCALE: 1/2" = 1'-O" <br />A <br />FLOOR <br />IC OR SECOND <br />LIVING SPACE <br />Mtn <br />z I I <br />cc <br />■ <br />i <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />W <br />rr- <br />�00� <br />> T_ 0 <br />ir <br />U)U�w <br />QZ)WI— <br />J U) W W <br />cccc rr_ <br />Y 0 — Z <br />LL O O cn <br />Z Z Z III <br />~z <br />a: Q J <br />wa=oCa <br />�C/)0Oc_Vn <br />H Q Z <br />rlt <br />cu <br />O � <br />Q <br />Q <br />U <br />O <br />� <br />O <br />0 <br />� � <br />w <br />U u <br />a <br />"ON"CL <br />ommw <br />a Un <br />U) <br />l< <br />w <br />w <br />w <br />U) <br />O <br />E <br />U <br />W <br />U) <br />Z <br />O� <br />to <br />c <br />�Z <br />aaaaa <br />i� <br />i <br />0 C T 5.2021 <br />COMMUNITY: <br />LINK <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 10/5/21 <br />SHEET <br />Av.2, <br />
The URL can be used to link to this page
Your browser does not support the video tag.