"yEw . ll T' 117 - '11
<br />System No. C-AJ-1259
<br />F Rating - 3 Hr
<br />T Rating - 0 Hr
<br />Section A -A
<br />1. Floor or Wall Assembly - Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Floor may also be
<br />constructed of any min 6 in. thick UL Classified hollow -core Precast Concrete Units*. Wall may also be constructed of any UL
<br />Classified Concrete Blocks*. Max diam of opening is 7 in.
<br />See Concrete Blocks (CAZT) and Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of
<br />manufacturers.
<br />2. Through Penetrants - One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the
<br />firestop system. The annular space between the pipe, conduit or tubing and the periphery of the opening shall be a min of 0 in.
<br />(point contact) to a max of 3 in. Pipe, conduit or tubing to be rigidly supported on both sides of floor or wall assembly. The
<br />following types and sizes of metallic pipes, conduit or tubing may be used:
<br />A. Steel Pipe - Nom 6 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.
<br />B. Iron Pipe - Nom 6 in. diam (or smaller) cast or ductile iron pipe.
<br />C. Conduit - Nom 4 in. diam (or smaller) steel electrical metallic tubing or steel conduit.
<br />D. Copper Tube - Nom 4 in. diam (or smaller) Type L (or heavier) copper tube.
<br />3. Forming Material - (Optional, Not Shown) - Mineral wool batt packing material or polyurethane backer rod friction fitted into
<br />opening and recessed from floor or wall surfaces as required to accommodate required thickness of fill material.
<br />4. Fill, Void or Cavity Material' - Sealant - Min 1/2 in. thickness of fill material applied within the annulus, flush with both
<br />surfaces of floor or wall. At the point contact location between penetrating item and concrete, a min 1/4 in. thick bead of fill
<br />material shall be applied at the concrete/penetrating item interface on both sides of floor or wall.
<br />SPECIFIED TECHNOLOGIES INC - SpecSeal Series SSS Sealant or SpecSeal LCI Sealant
<br />*Bearing the UL Classification Mark
<br />Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876
<br />Reproduced courtesy of Underwriters Laboratories, Inc.
<br />STI Created or Revised: January 2, 2009 8 C-AJ-1259
<br />(800)992-1180 - (908)526-8000 - FAX (908)231-8415 - E-Mail:techserv@stifirestop.com - Websitemww.stifirestop.com PAGE 1 OF 1
<br />System No. W-L-1079
<br />F Ratings - 1 and 2 Hr (See Item 1B)
<br />T Rating - 0 Hr
<br />L Rating At Ambient - Less Than 1 CFM/sq ft
<br />L Rating At 400 F - Less Than 1 CFM/sq ft
<br />OeG110(1 H-/A
<br />1. Wall Assembly - The 1 or 2 hr fire -rated gypsum board/stud wall assembly shall be constructed of the materials and in the
<br />manner described in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall
<br />include the following construction features:
<br />A. Studs - Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in.
<br />lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3-5/8 in. wide and
<br />spaced max 24 in. OC.
<br />B. Gypsum Board - 5!8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of
<br />layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire
<br />Resistance Directory. Max diam of opening is in wood stud walls is 13 in. Max diam of opening in steel stud walls is 16 in.
<br />The hourly F rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed.
<br />2. Through Penetrant - One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop
<br />system. The annular space between pipes or conduits and periphery of opening shall be min 0 in. (point contact) to max 3 in.
<br />Pipe or conduit to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or
<br />conduits may be used:
<br />A. Steel Pipe - Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.
<br />B. Iron Pipe - Nom 12 in. diam (or smaller) cast or ductile iron pipe.
<br />C. Conduit - Nom 4 in. diam (or smaller) electrical metallic tubing, nom 6 in. diam (or smaller) steel conduit or nom 1 in. diam
<br />(or smaller) flexible steel tubing.
<br />D. Copper Pipe - Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe.
<br />E. Copper Tube - Nom 6 in. diam (or smaller) Type L (or heavier) copper tube.
<br />79 Specified Technologies Inc. 210 Evans Way Somerville, NJ 08876
<br />Reproduced courtesy of Underwriters Laboratories, Inc.
<br />STI Created or Revised: January 2,2009 W L 1079
<br />(B00)992-1180 - (908)526-8000 - FAX (908)231-8415 - E-MaiLtechserv@stifirestop.com - Websitemww.stifirestop.com PAGE 1 OF 2
<br />LA
<br />G6
<br />E
<br />G1
<br />EX
<br />r— N—------
<br />EW
<br />I
<br />r
<br />NEW RISER WORK
<br />——————— — — — —-�
<br />I
<br />LC EX L J
<br />200
<br />EX NP rD200
<br />X '
<br />33d it AF
<br />❑
<br />O CTM
<br />NEW
<br />I PNL I
<br />100
<br />EX
<br />i A I
<br />100.S
<br />200 M200
<br />CT
<br />I I
<br />CABINETI
<br />20m I
<br />EX
<br />CT
<br />i
<br />L—— — — —--�
<br />WW
<br />ELECTRICAL RISER DIAGRAM
<br />MISCELLANEOUS NOTES:
<br />FXFMR
<br />EXISTING UTILITY COMPANY PAD MOUNTED
<br />TRANSFORMER. SECONDARY VOLTAGE TO BE
<br />120/200Y 3 PHASE, 4 WIRE WYE_
<br />LA
<br />EXISTING UL LISTED LIGHTNING ARRESTOR,
<br />SQUARE D OR APPROVED EQUIVALENT,
<br />ww
<br />EXISTING 12"X12"X 12" NEMA 3R WIREWAY,
<br />EXTEND FEEDER CONDUCTORS THE ENTIRE
<br />LENGTH OF THE WIREWAY AND TERMINATE
<br />WITH INSULATED KEY TAP STYLE
<br />CONNECTORS. I LSCO OR APPROVED
<br />EQUIVALENT.
<br />EXISTING LIGHTING CONTACTORS) AND
<br />LC TIMEGLOCK IN NEMA 3R ENCLOSURE_ REFER
<br />TO DETAIL ON THIS SHEET FOR
<br />REQUIREMENTS
<br />D2 00 EXISTING A 200 AMP, 3 POLE, NEMA 3R,
<br />SERVICE ENTRANCE RATED HEAVY DUTY
<br />FUSED DISCONNECT SWITCH WITH SOLID
<br />NEUTRAL KIT_ FUSE AT 200 AMPS WITH CLASS
<br />RKl FUSES.
<br />D8 00 EXISTING SOO AMP, 3 POLE, NEMA 3R,
<br />SERVICE ENTRANCE RATED HEAVY DUTY
<br />FUSED DISCONNECT SWITCH WITH SOLID
<br />NEUTRAL KIT. FUSE AT 800 AMPS WITH CLASS
<br />L FUSES.
<br />FEEDER NOTES: F7
<br />1200.5
<br />(EXISTING SERVICE LATERAL - 1200 AMPS)
<br />(3) SETS OF 4 0600 KCMIL IN 4" C
<br />ROUTED UNDER GROUND EXTERIOR OF
<br />THE BUILDING
<br />800.
<br />(EXISTING SERVICE ENTRANCE -000 AMPS)
<br />(2) SETS OF 4 0600 KCMIL IN 4" C
<br />ROUTED UNDER GROUND EXTERIOR OF
<br />THE BUILDING
<br />(EXISTING SERVICE ENTRANCE - 200 AMPS)
<br />200.
<br />4 03/0 AND 1 04 BONDING
<br />CONDUCTOR IN 2" C
<br />200
<br />(NEW FEEDER - 200 AMPS)
<br />113/0 IN
<br />EXTEND 4 AND 1"(o E G. 2" C
<br />(EXISTING SERVICE ENTRANCE - 100 AMPS
<br />100.S
<br />4 *1 AND 104 BONDING
<br />CONDUCTOR IN 1-1/2" C
<br />I PA'\EL I 1 FLUSHED
<br />O 208 OLT t SE
<br />NIED
<br />A PH.4
<br />4 fit' IRE WITH GROU.\D
<br />EX
<br />14�1�3 AFC
<br />I LA I
<br />1200.S
<br />ErT
<br />EX
<br />EX
<br />METER NOTES:
<br />CT
<br />EXISTING 3(o" X 36" X 12" NEMA 3R CT
<br />CABINET WITH LOCKABLE HASP. VERIFY
<br />EXACT REQUIREMENTS WITH UTILITY
<br />COMPANY PRIOR TO ROUGH -IN.
<br />FC T M
<br />EXISTING 3 PHASE CT METER BASE PER
<br />UTILITY COMPANY SPEC.
<br />FM20
<br />EXISTING 200 AMP 3 PHASE SELF
<br />CONTAINED METER BASE PER UTILITY
<br />COMPANY SPEC.
<br />GROUND INCx/BONDING NOTES: =
<br />G1 IEXISTING
<br />3/0 CU GROUND ELECTRODE
<br />CONDUCTOR IN 3/4" CONDUIT_
<br />EXISTING 3/4" X 10' LONG COPPER CLAD
<br />G2
<br />GROUND,
<br />G3
<br />EXISTING GROUND ELECTRODE SYSTEM
<br />CONNECTION TO A REBAR IN THE BUILDING
<br />FOUNDATION AND BUILDING STEEL.
<br />G4
<br />EXISTING METALLIC COLD WATER PIPE
<br />CONNECTION TO GROUND ELECTRODE SYSTEM.
<br />G6
<br />EXISTING METER AND CT CABINET
<br />CONNECTION TO GROUND ELECTRODE
<br />SYSTEM WITH A M4 CU GEC IN 3/4" CONDUIT_
<br />'ES
<br />C1-T.
<br />I
<br />DESCRIPTION
<br />BREAKER
<br />A
<br />B
<br />NO.
<br />TRIP
<br />POLE
<br />VOLT
<br />I
<br />I
<br />OI-TICE,EXAM.TOILET RN,ISLTS E.�I
<br />20
<br />1
<br />120
<br />812 '50
<br />1
<br />__1
<br />COi.RIDOR.'RECRPTIO'\5 LTS:'E\I
<br />_0
<br />1
<br />124
<br />1
<br />5
<br />OFF ICE,EXA_II ST.R?.SSLTS'E\d
<br />20
<br />1
<br />120
<br />1
<br />7
<br />ct ITINGAREALIGHT.EM
<br />20
<br />1
<br />120
<br />1034 1200
<br />2
<br />9
<br />E.,AwI-119'121 REC.
<br />20
<br />1
<br />120
<br />540 1000
<br />2
<br />11
<br />E\4\L 1_v'121 RFC.
<br />_'0
<br />1
<br />120
<br />{
<br />13
<br />WAITING ROO\I EWC
<br />20
<br />1
<br />120
<br />-;0 1000
<br />2
<br />15
<br />V, AITING ROO\I RECEPTACLES
<br />20
<br />1
<br />120
<br />900 1200
<br />2
<br />17
<br />CHECK IN PALTER
<br />20
<br />1
<br />110
<br />2
<br />19
<br />CHECK IN RE CEP
<br />20
<br />1
<br />120
<br />720 1 900
<br />21
<br />SPARE
<br />24
<br />1
<br />12.0
<br />540
<br />SPARE
<br />20
<br />1
<br />120
<br />4
<br />25
<br />EWH
<br />30
<br />2
<br />208
<br />2250 1 1000
<br />4
<br />?-
<br />2250 ,a�
<br />_
<br />29
<br />MEZ-1ANI\TRECIPTACLES
<br />20
<br />1
<br />120
<br />3
<br />31
<br />CU-1
<br />30
<br />3
<br />208
<br />1'.•52 1-40
<br />3
<br />33
<br />----
<br />1752 1 1740
<br />4
<br />3?
<br />AI;i;-1
<br />60
<br />2
<br />208
<br />4176
<br />4
<br />39
<br />-- -
<br />41-6 1 4374
<br />41
<br />SPA C'E
<br />t
<br />CONNT-CTED VA
<br />SYSTEM VOLTS
<br />PHA SF. A\.PS
<br />1808 #
<br />21127
<br />12020SV.3PHASE
<br />1511
<br />176
<br />C
<br />BREAKER
<br />DESCRIPTION(
<br />VOLT
<br />POLE
<br />TRIP
<br />120
<br />1
<br />.0
<br />1 TELEPHONE RECEPTACLE
<br />120
<br />1
<br />20
<br />1 IT RECEPTA CLES
<br />1210 750
<br />120
<br />1
<br />20
<br />TIME CiOCKr`REC'EPTACLES
<br />120
<br />1
<br />20
<br />BREAKR-it REFRIGERATOR
<br />120
<br />1
<br />20
<br />BREAKRIM COL TER RECEPT.
<br />1080 1500
<br />120
<br />1
<br />20
<br />BREAKRM MICROWAVE
<br />120
<br />1
<br />20
<br />BREAK Rive COUNTER RECEPT.
<br />120
<br />1
<br />20
<br />BREAK RIM C;ARBAGE.DISPOSAL
<br />1000 1200
<br />120'
<br />1
<br />20
<br />SIGNS
<br />120
<br />1
<br />20
<br />EXAM RBI : 109.+'107N RSE REC.
<br />1.0
<br />1
<br />7
<br />.0
<br />[ i t
<br />E�.�.4I RVI � 109 10. T,FL'RSE RE:C:.
<br />720
<br />120
<br />1
<br />20
<br />E..XA�M R_M =101`N'U7RSEREC.
<br />120
<br />1
<br />20
<br />NURSE RECEPTACLES
<br />120
<br />1
<br />20
<br />OFFICES -EXAM R V1 # 115:'1IS REC.,
<br />360 1080
<br />120
<br />1
<br />20
<br />OFFIC S EXAM R'43 s1151118 RFC.
<br />208
<br />3
<br />30
<br />CU-2
<br />1752- 1 1740
<br />120,1 1 1 20 1 SPARE
<br />208 1 3 1 60 1 AHU'-2.
<br />4374 -----
<br />16766
<br />NOTES
<br />LOAD TYPE
<br />IS LARGER
<br />CO` CTED
<br />\EC DENIAND
<br />DENMAN"1D LOAD
<br />I
<br />LIGHTING
<br />5081
<br />1.25
<br />635125 VA
<br />8920 VA
<br />0 VA
<br />21600 VA
<br />99G0 VA
<br />0 VA
<br />0 VA
<br />46771 VA
<br />2
<br />RECEPTACLES
<br />8920
<br />1
<br />3
<br />AIR C'O\DITIONI\G
<br />10476
<br />©
<br />4
<br />HEATING
<br />21600
<br />1
<br />5
<br />tvIISC. tdON-CONTIPIUOUG
<br />9900
<br />1
<br />6
<br />CONTINUOUS
<br />0
<br />1:25
<br />KITCHEN
<br />0
<br />0.65
<br />TOTAL
<br />120 20 I., 3 PIiA
<br />SE
<br />130 AtvtPS
<br />DOTES ( }
<br />G3
<br />MLO
<br />Al
<br />)AFC
<br />8 2
<br />30 2
<br />32. 3
<br />34 3
<br />36 3
<br />38
<br />F44
<br />42
<br />ELECTRICAL SPECIFICATIONS:
<br />THE WORK UNDER THE REQUIREMENTS OF THESE SPECIFICATIONS SHALL BE
<br />OIN CONFORMANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL
<br />CODE, THE INSTALLATION SHALL ALSO COMPLY WITH ALL APPLICABLE
<br />RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES.
<br />OALL ELECTRICAL EQUIF ,LENT SHALL HAVE UL LABEL AND SHALL BE OF
<br />SPECIFICATION GRADE
<br />POWER DISTRIBUTION HOUSE PANELBOARD: PROVIDE DEAD -FRONT,
<br />OSAFETY -TYPE POWER DApTRIBUTION PANELBOARDS AS INDICATEDt WITH
<br />PANELBOARD SWITCH*AND PROTECTIVE DEVICES IN QUANTITIES, RATINGS,
<br />TYPES, AND WITH ARRANGEMENT SHOWNt WITH ANTI -TURN, SOLDERLESS
<br />PRESSURE TYPE MAIN LUG CONNECTORS APPROVED FOR USE WITH COPPER
<br />CONDUCTORS.
<br />®PANELBOARDS EQUAL TO SQUARE D TYPE "QO", VOLTAGE SHALL BE AS
<br />INDICATED_ ACCEPTABLE MFG.t G.E., SIEMENS AND CUTLER -HAMMER
<br />ALL PANEL50ARDS SHALL BE CONNECTED, DISTRIBUTED PHASE WITH
<br />OCIRCUIT NUMBERING AS INDICATED ON THE DRAWINGS. PANELBOARDS SHALL
<br />BE NUMBERED WITH ODD NUMBERS ON THE LEFT SIDE OF THE PANEL AND
<br />EVEN NUMBERS ON THE RIGHT SIDE OF THE PANEL.
<br />UNLESS OTHERWISE INDICATED, PROTECTIVE DEVICES SHALL BE MOUNTED
<br />OWITH TOP OF CABINET OR ENCLOSURE 6'-6" ABOVE FINISHED FLOOR, SHALL
<br />BE PROPERLY ALIGNED, AND SHALL BE ADEQUATELY SUPPORTED
<br />INDEPENDENTLY OF THE CONNECTING RACEWAYS. ALL STEEL SHAPES, ETC.,
<br />NECESSARY FOR THE SUPPORT OF THE EQUIPMENT SHALL BE FURNISHED
<br />AND INSTALLED BY THE CONTRACTOR WHERE THE BUILDING STRUCTURE IS
<br />NOT SUITABLE FOR MOUNTING THE EQUIPMENT DIRECTLY THEREON, UNLESS
<br />OTHERWISE INDICATED, ALL BRANCH CIRCUIT PROTECTIVE DEVICES
<br />ENCLOSURES SHALL BE NEMA TYPE 1, GENERAL PURPOSE TYPE. CIRCUIT
<br />PROTECTIVE DEVICES INSTALLED OUTDOORS OR EXPOSED TO THE
<br />WEATHER SHALL HAVE WEATHERPROOF ENCLOSURES, NEMA TYPE "3R" OR
<br />TYPE "4"
<br />ALL SAFETY SWITCHES SHALL BE GENERAL DUTY TYPE_ SWITCH MECHANISM
<br />OSHALL BE QUICK -MAKE, QUICK -BREAK_ COVER SHALL BE INTERLOCKED WITH
<br />MECHANISM TO PREVENT OPENING UNLESS SWITCH IS IN THE "OFF" POSITION,
<br />ALL ENCLOSURES SHALL BE PRIMED AND FINISHED TO RESIST RUSTING AND
<br />CORROSION_ SWITCHES SHALL BE ITE, GENERAL ELECTRIC, SQUARE-D, OR
<br />CUTLER -HAMMER
<br />OCIRCUIT BREAKERS FOR MOUNTING IN HOUSE PANELBOARD SHALL BE
<br />BOLT -ON OR PLUG IN TYPE, MOLDED PLASTIC CASE, AIR CIRCUIT BREAKER
<br />TYPE. BREAKERS SHALL HAVE THERMAL MAGNETIC TRIP UNITS AND
<br />MULTI -POLE BREAKERS SHALL HAVE A COMMON TRIP BAR SO THAT THE
<br />TRIPPING OF ONE POLE WILL AUTOMATICALLY TRIP ALL POLES OF THE
<br />BREAKER BREAKERS SHALL BE TRIP FREE AND TRIP INDICATING AND
<br />SHALL HAVE QUICK -MAKE, QUICK -BREAK CONTACTS.
<br />®UPON COMPLETION OF WORK CORRECT ALL PANELBOARD CIRCUIT
<br />DIRECTORY CARDS TO REFLECT AS -BUILT CONDITIONS. PANELBOARD
<br />DIRECTORIES SHALL BE UPDATED WITH TYPEWRITTEN ACCURATE AND
<br />CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION_
<br />DIRECTORIES SHALL REFLECT RECORD CONDITIONS AND INCLUDE CIRCUIT
<br />NUMBER, TYPE AND LOCATION OF LOAD. A SET OF AS -BUILT DRAWINGS
<br />SHALL ALSO BE PREPARED AND TURNED OVER TO THE OWNER
<br />ALL CONDUCTORS SHALL BE THHN/TI-IWN COPPER 012 MIN. AND INSTALLED IN
<br />10 A COMPLETELY ENCLOSED RACEWAY SYSTEM. FEEDERS MAY BE ALUMINUM
<br />WHEN LARGER THAN 06 AWG
<br />UNLESS SPECIFICALLY NOTED ON DRAWINGS, RACEWAYS SHALL COMPLY
<br />11 WITH THE FOLLOWING:
<br />RACEWAYS EXPOSED TO THE WEATHER OR IN DAMP LOCATIONS
<br />O12 SHALL BE SCHEDULE 40 PVC OR GALVANIZED RIGID STEEL WITH
<br />THREADED CONNECTIONS WHEN EXPOSED TO DAMAGE_
<br />RACEWAYS SHALL BE SIZED FOR THE CONDUCTORS INSTALLED,
<br />MINIMUM 1/2 FULL SIZE MC CABLE IS ACCEPTABLE IN DRY LOCATIONS.
<br />13 HOME RUNS TO PANELS TO BE IN CONDUIT,
<br />14 RACEWAYS RUN BELOW GRADE SHALL BE SCHEDULE 40 PVC
<br />ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY
<br />15 SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS, AND
<br />EQUIPMENT_
<br />16 ALL RACEWAYS SHALL BE SECURELY SUPPORTED FROM THE BUILDING
<br />STRUCTURE_
<br />O ALL RACEWAYS SHALL BE PROVIDED WITH EQUIPMENT GROUND CONDUCTOR -
<br />ALL BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH
<br />18 SUITABLE SCREW FASTENED COVERS, OPEN KNOCK -OUTS OR HOLES IN
<br />BOXES SHALL BE PLUGGED WITH A SUITABLE BLANKING DEVICES.
<br />OUTLET 5OXE5 FOR EXPOSED WALL MOUNTING AND OUTDOOR INSTALLATION
<br />1g SHALL BE CAST METAL TYPE "FS" OR "FD" BOXES WITH SUITABLE
<br />GALVANIZED SHEET STEEL COVERS, OR CAST METAL WEATHERPROOF OR
<br />VAPOR TIGHT COVERS WHEN NOTED ON THE DRAWINGS.
<br />UNLESS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE COPPER NO. 12
<br />20 AW'Cs_ MINIMUM. OR SIZE AS SHOWN ON DRAWINGS. CONDUCTORS SHALL HAVE
<br />TYPE ' 'THHN/THWN' INSULATION.
<br />SPLICES, TAPS AND ATTACHMENT FITTINGS AND LUGS SHALL BE
<br />21 ELECTRICALLY AND MECHANICALLY SECURE AND SOLDERLESS FOR
<br />CONDUCTORS SIZES NO. 8 AUG AND LARGER THERE SHALL BE PLENTY OF
<br />SLACK CABLE IN BOXES, OUTLETS AND CABINETS TO INSURE THAT THERE 15
<br />NO BINDING AT THE BUSHINGS. ALL LUGS SHALL BE OF THE CORRECT SIZES
<br />FOR THE CONDUCTORS JOINED AND IN NO CASE SHALL STRANDS BE CUT
<br />FROM A CONDUCTOR IN ORDER TO FIT THE CONDUCTOR INTO A LUG. TAPING
<br />OF JOINTS SHALL BE WITH VINYL PLASTIC ELECTRICAL TAPE TO SECURE
<br />INSULATION STRENGTH EQUAL TO THAT OF THE CONDUCTORS JOINED_
<br />22 THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND
<br />EFFECTIVELY GROUNDED AS REQUIRED BY THE NEC AND AS SPECIFIED
<br />HEREINAFTER.
<br />23 CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS.
<br />THE CONTRACTOR SHALL VERIFY ALL LOCATIONS WITH THE OWNER PRIOR TO
<br />INSTALLATION. THEY SHALL NOT BE CHARGED FOR MINOR LOCATION
<br />24 CHANGES PRIOR TO INSTALLATIONS. LOCATIONS ARE APPROXIMATE, (DO
<br />NOT SCALE DRAWINGS).
<br />THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL ELECTRICAL
<br />25 LAYOUTS FOR BIDDING PURPOSES ONLY. IT IS THE RESPONSIBILITY OF THE
<br />CONTRACTOR TO PREPARE DETAILED SHOP DRAWINGS AND CONFIRM
<br />SPACE ALLOCATIONS.
<br />THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES
<br />' 26FOR ELECTRICAL CONDUIT ROUTING AND EQUIPMENT PLACEMENT. AVOID
<br />O
<br />INTERFERENCE WITH ARCHITECTURAL AND STRUCTURAL FEATURES SUCH AS:
<br />BEAMS, FOOTINGS, WINDOWS, ETC. NOTIFY ARCHITECT IMMEDIATELY OF ANY
<br />CONFLICTS_
<br />THE ELECTRICAL CONTRACTOR THE HVAC FOREMAN AND GENERAL
<br />27 CONTRACTOR PROJECT MANAGER SHALL INSPECT a REVIEW THE
<br />CONDITIONS, AND SHALL COORDINATE THEIR WORK SO AS TO PROVIDE
<br />ADEQUATE SPACE ALLOWANCE ABOVE CEILING FOR ALL TRADES -
<br />THE PLANS SHOW THE LOCATION OF ALL FIXTURES AND EQUIPMENT AND ARE
<br />28 INTENDED TO DEPICT THE GENERAL INTENT OF THE WORK IN SCOPE, LAYOUT
<br />AND QUALITY OF WORKMANSHIP. THEY ARE NOT INTENDED TO SHOW IN MINUTE
<br />DETAIL EVERY AND ALL ACCESSORIES INTENDED FOR THE PURPOSE OF
<br />EXECUTION OF THE WORK, BUT SHALL BE UNDERSTOOD THAT SUCH DETAILS
<br />WILL BE PART OF THIS WORK.
<br />THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE
<br />29 AND FUNCTIONAL SYSTEM: CONTROLS, AND CONNECTIONS TO NEW SERVICES,
<br />SUPPORTS, AND HARDWARE REQUIRED FOR THE SATISFACTORY OPERATION
<br />OF THE SYSTEM, WHETHER SPECIFICALLY SHOWN OR NOT ON THE DRAWINGS.
<br />WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, IT SHALL BE THE
<br />30 RESPONSIBILITY OF THIS CONTRACTOR TO BRING SUCH CONFLICT TO THE
<br />ATTENTION OF THE ENGINEER FOR CLARIFICATION.
<br />E-LECTfRICAL S"T'1150L LEGEND
<br />SYMBOL
<br />DESCRIPTI❑N
<br />M❑UNTING
<br />- g
<br />I X 4 FLUORESCENT FIXTURE
<br />SEE FIXTURE
<br />LETTER INDICATES TYPE
<br />SCHEDULE
<br />X 4 FLUORESCENT FIXTURE
<br />SEE FIXTURE
<br />F2
<br />LETTER INDICATES TYPE
<br />SCHEDULE
<br />SHADING DENOTES FIXTURE WITH EM BATTERY PACK.
<br />SEE FIXTURE
<br />'NL' DENOTES FIXTURE UNSWITCHED FOR NIGHT LIGHT
<br />SCHEDULE
<br />FLUORESCENT STRIP FIXTURE
<br />SEE FIXTURE
<br />LETTER INDICATES TYPE
<br />SCHEDULE
<br />FLUORESCENT WALL BRACKET FIXTURE
<br />SEE FIXTURE
<br />LETTER INDICATES TYPE
<br />O
<br />PL FLUORESCENT DOWNLIGHT
<br />SEE FIXTURE
<br />LETTER INDICATES TYPE
<br />SCHEDULE
<br />I-6 EX
<br />EXIT -SHADING DENOTES FACEPLATE LOCATION_ LETTER
<br />SEE FIXTURE
<br />INDICATES TYPE. PROVIDE ARROWS AS REQUIRED.
<br />SCHEDULE
<br />SINGLE POLE SWITCH (20A-120/277)
<br />48" AFF OR AS
<br />S S3 So
<br />'3' DENOTES 3;WAY 'O' DENOTES OCCUPANCY SENSOR
<br />NOTED
<br />DUPLEX RECEPTACLE, 125V, 20A
<br />16" AFF OR AS
<br />'IG' DENOTES ISOLATED GROUND
<br />NOTED
<br />DUPLEX RECEPTACLE, 125V, 20A
<br />16" AFF OR AS
<br />NOTED
<br />&
<br />DUPLEX RECEPTACLE, 125V, 20A
<br />46" AFF OR AS
<br />NOTED
<br />0
<br />QUADRAPLEX RECEPTACLE, 125V, 20A
<br />16" AFF OR AS
<br />NOTED
<br />0
<br />COMBINATION VOICE/DATA OUTLET
<br />10" AFF OR AS
<br />NOTED
<br />TV
<br />T.V_ OUTLET
<br />18" AFF OR AS
<br />NOTED
<br />PANELBOARD 120/240V
<br />SEE PANEL
<br />SCHEDULE
<br />�-�
<br />RACEWAY CONCEALED IN WALL OR ABOVE CEILING
<br />SEE SPECIFICATIONS
<br />HOMERUN TO PANEL. LETTERS INDICATE PANEL,
<br />SEE SPECIFICATIONS
<br />NUMBERS INDICATE CIRCUIT. NOTE: HASH MARKS
<br />INDICATES THE NUMBER OF WIRES EXCLUDING
<br />THE REQUIRED EQUIPMENT GROUND.
<br />/ �✓
<br />MOTOR, NUMERAL INDICATES HORSEPOWER
<br />AS NOTED
<br />MOTOR RATED SWITCH WITH OVERLOAD
<br />MOUNTED ADJACENT
<br />RELAYS IF REQUIRED.
<br />TO EQUIPMENT
<br />NON -FUSIBLE SAFETY SWITCH -SIZE AS NOTED
<br />SEE SPECIFICATIONS
<br />FUSIBLE SAFETY SWITCH-51ZE AS NOTED
<br />SEE SPECIFICATIONS
<br />2 R
<br />�s
<br />FIRE ALARM DUCT DETECTOR CRA'DENOTES
<br />MOUNTED IN
<br />RETURN AIR 'SA' DENOTES SUPPLY AIR)
<br />HVAC DUCTWORK
<br />®
<br />FAN OR AIR HANDLER SHUTDOWN RELAY
<br />MOUNTED ADJACENT
<br />TO EQUIPMENT
<br />0
<br />FIRE ALARM VISUAL SIGNAL
<br />00" AFF OR
<br />AS NOTED
<br />FIRE ALARM MANUAL PULLSTATION
<br />48" AFF ORAS
<br />NOTED
<br />FIRE ALARM AUDIBLE/VISUAL SIGNAL, ADA
<br />80" AFF OR
<br />Z<
<br />COMPATIBLE ,
<br />AS NOTED
<br />FIRE ALARM SMOKE DETECTOR
<br />ON CEILING ORAS
<br />NOTED
<br />FACPP
<br />FIRE ALARM PANEL CFACP' DENOTES FIRE ALARM
<br />60" AFF OR
<br />FAA
<br />CONTROL PANEL, 'FAA' DENOTES ANNUNCIATOR)
<br />AS NOTED
<br />EX
<br />DENOTES EXISTING DEVICE OR CIRCUIT TO REMAIN
<br />R
<br />DENOTE NEW LOCATION FOR RELOCATED DEVICE
<br />O O
<br />I REFER TO LIKE NUMBERED NOTES
<br />NOTE: ALL MOUNTING HEIGHTS SHOWN ARE TO THE TOP OF THE
<br />DEVICE UNLESS NOTED OTHERWISE.
<br />NOT ALL SYMBOLS APPEAR ON PLANS,
<br />ABBREVIATIONS:
<br />AFF -
<br />ABOVE FINISHED FLOOR
<br />AHU -
<br />AIR HANDLING UNIT
<br />BFG -
<br />BELOW FINISHED GRADE
<br />C -
<br />CONDUIT r
<br />CW -
<br />COOL WHITE
<br />DACP -
<br />DOOR ALARM CONTROL PANEL
<br />DN -
<br />DOWN
<br />EF -
<br />EXHAUST FAN
<br />EG -
<br />EQUIPMENT GROUND
<br />ENCL -
<br />ENCLOSURE
<br />EWC -
<br />ELECTRIC WATER COOLER
<br />EWH -
<br />ELECTRIC WATER HEATER
<br />EX -
<br />EXISTING
<br />FCU -
<br />FAN COIL UNIT
<br />FHP -
<br />FRACTIONAL HORSE POWER
<br />FLA -
<br />FULL LOAD AMPERES
<br />G -
<br />GROUND
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />_
<br />HID
<br />HIGH INTENSISTY DISCHARGE
<br />HORIZ -
<br />HORIZONTAL
<br />IG -
<br />ISOLATED GROUND
<br />LW -
<br />LIGHT WHITE .
<br />HP -
<br />HORSEPOWER, HEAT PUMP
<br />HVAC -
<br />HEATING, 5ENTIATING AI RCONDITIONING
<br />JB -
<br />JUNCTION BOX
<br />LRA -
<br />LOCKED ROTOR AMPERES
<br />MCB -
<br />MAIN CIRCUIT BREAKER
<br />MLO -
<br />MAIN LUGS ONLY
<br />N -
<br />NEW
<br />NL -
<br />NIGHT LIGHT
<br />OB -
<br />OUTLET BOX
<br />PB -
<br />PULL BOX, PUSH-BUTTON
<br />R -
<br />RELOCATED
<br />RECEPT -
<br />RECEPTACLE
<br />SF -
<br />SUPPLY FAN
<br />SPEC -
<br />SPECIFICATIONS
<br />SWECS -
<br />SMOKE WARNING EMERGENCY CALL SYSTEM
<br />TL -
<br />TWISTLOCK
<br />TTB -
<br />TELEPHONE TERMINAL BOARD
<br />TVTB -
<br />TELEVISION TERMINAL BOARD
<br />UNO -
<br />UNLESS NOTED OTHERWISE
<br />VERT -
<br />VERTICAL
<br />WM -
<br />WATT MISER
<br />WP -
<br />WEATHERPROOF
<br />WW -
<br />WARM WHITE .
<br />XFMR -
<br />TRANSFORMER
<br />0 ELECTRICAL FIRE STING DETAILS 0 ELECTRICAL F ANEL SCHEDULE O ELECTRIC,�-�� LEGEND AND SPECIFICATIONSTING
<br />NOT TO SCALE SCALE: NOT TO SCALE SCALE: NOT TO SCALE
<br />REVISIONS
<br />BY
<br />f
<br />r,.
<br />00
<br />u cT cn
<br />M CU
<br />0 00 o
<br />v
<br />z N vi
<br />` t
<br />N �n'L2
<br />N
<br />¢ E
<br />O
<br />3
<br />00
<br />3 � 3
<br />0
<br />�-- o z N .
<br />M
<br />3
<br />�4
<br />' �ggCBi aSE��J
<br />�
<br />{{tt
<br />SE - OF
<br />�J 3 NA, Y� n
<br />I it
<br />'''r +'
<br />,
<br />W U 0
<br />U
<br />Z
<br />0 J
<br />L
<br />J
<br />-��- —J
<br />C Q -0
<br />L)m N
<br />LLJ L
<br />v w a
<br />� Q N
<br />3
<br />N
<br />z
<br />O
<br />LI_
<br />Date: 04. 15. 13
<br />Scale: AS NOTED
<br />Project Mgr: AAY
<br />Drawn: IIT
<br />Job: 13-08b
<br />Sheet
<br />E(
<br />
|