ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6, Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles In laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included In the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />31 W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />Lzn­ <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />0 <br />EXHAUST FAN <br />;O% <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PO <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Ja <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I j <br />I I <br />I I <br />LAV <br />-1 I <br />L TUB/ <br />W/C SHOWER <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I <br />I <br />U W/C <br />ii <br />SHOWER <br />—nd F SLR <br />STUDOR <br />VENTQ I , DBL SINK <br />L T� W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -B- (1516) <br />SQ. FT. AT 3 WATTS / SO. F.T. <br />1505 S.F. <br />4515 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10515 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />9 <br />SUBTOTAL: 23060 <br />TOTAL: 33575 <br />st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9430 <br />AIR CONDITIONER WATTS AT 100% <br />1 <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31734 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service 200A <br />Same As Underground Indoor Panel <br />150 Or 200 Amp Service Center <br />NEMA 1 <br />200 AMP <br />TER MA N <br />1 F0-200 AMP I IT /—Serial Cable <br />NEMA <br />3R <br />Power Co. Feed ---- I J I- <br />---T— #4 Solid COPPER Ground <br />C.O. <br />II <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DISCONNECT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />I <br />II <br />I <br />I <br />I <br />L <br />1 UPSTAIRS G <br />0 <br />------------------------- <br />OUTDOOR LIVING <br />INSTALL LIGHT <br />ROUGH -IN <br />< FOR OPT. <br />GFI i AN/LIGHT <br />.nW <br />-r----- ` <br />DINING <br />KITCHEN <br />1 <br />o Gf� \ \ <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />PP <br />GREAT ROOM <br />ROUGH -IN<:',\ <br />I FOR OPT. <br />1 FAN/LIGHT<� <br />1 <br />1 I <br />I <br />\ / <br />W.H. I <br />@ <br />0 / <br />A. <br />1 <br />I <br />GARAGE1 <br />I I <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />I <br />I <br />I <br />I� <br />I <br />I <br />Z IW <br />O Iq <br />I <br />Q Ia <br />I <br />010 <br />KIW <br />I <br />>IWI <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DB -°wP �I <br />ENT <br />®GFI ICJ LIGHT <br />PER SPE <br />I <br />I <br />I <br />1 <br />H <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />1ST ELECTRICAL - UNIT-B 1516 <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL -UNIT-B 1516 <br />SCALE: Y"=V-0" <br />"(D <br />oti� <br />N <br />`_ U cv <br />TJ U <br />- <br />Z <br />U r-'. �i <br />� <br />� <br />cu e, <br />.;• <br />O O <br />U "; <br />e <br />2 11J <br />0 <br />N <br />0 <br />N_ <br />N <br />To the beat of the Engineer's knowledge, information and bell ef, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code . <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />E 1` <br />4 <br />Lo <br />$ C' LL <br />LL <br />0?$ W <br />W <br />. <br />i��r=32 - ty a <br />Z <br />U. a Y <br />Zg� <br />OF t <br />W <br />A N p m GQ J <br />�` T <br />= <br />MZo, <br />y� <br />0 <br />°" UaILW <br />od <br />o <br />0 <br />Z om§Z W <br />z <br />N <br />N <br />f_p <br />�U <br />W <br />0 <br />L. <br />UNL <br />N <br />C <br />c <br />Q Y <br />C' co <br />sr <br />o <br />Cl) <br />w <br />ZM <br />_j <br />o <br />o <br />�o <br />o <br />�- <br />® <br />Q <br />c <br />Z <br />O <br />p <br />pq <br />a� <br />O <br />0 <br />az <br />�� <br />ry <br />C <br />Qom= <br />o <br />Z <br />ZCn <br />N J <br />' <br />0b� <br />az <br />Ji <br />oa <br />U <br />�0 <br />�W <br />�G <br />�! <br />o T <br />ui <br />125 <br />N <br />I <br />0 <br />cfl <br />T <br />O <br />CV <br />Itn <br />r <br />50 <br />N <br />04 <br />� <br />C <br />OI <br />N <br />w <br />coo <br />E <br />T <br />Q <br />r <br />Z <br />m <br />E 0 <br />E <br />N <br />a? <br />co <br />c <br />o <br />U � <br />Q p <br />JOB <br />NO: 21-17099-17106 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />14 <br />r <br />