Laserfiche WebLink
El <br />COMPONENTS AND CLADDING <br />140 Ul t DESIGN WIND PRESSURE FOR WALLS, DOORS & <br />WINDOWS (NOMINAL) <br />COMPONENT <br />ZONE <br />EFFECTIVE WIND AREA <br />WALL <br />10 SQ, FT. <br />20 SQ, FT. <br />50 SQ. FT, <br />100 SQ� <br />FT, <br />500 SQ, FT. <br />WALL <br />+35,3 PSF I -382 PSF <br />+33.7 PSF / -36,7 PSF <br />+31,6 PSF / -34A PSF <br />+30.0 PSF / <br />-33,0 PSF <br />+263 PSF / -293 PSF <br />WALL <br />+35.3 PSF / -47.2 PSF <br />+33,7 PSF / -44,0 PSF <br />+31,6 PSF / -39.8 PSF <br />+30,0 PSF / <br />-363 PSF <br />+26.3 PSF / -29,3 PSF <br />NOTE, <br />ALL EXTERIOR DOORS & WINDOWS ASSEMBLIES SHALL SATISFY THE REQUIREMENTS IN FBC 2010, ALL CONNECTIONS TO BUILDING STRUCTURE <br />SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES INDICATED IN THIS SCHEDULE, <br />3'-0" FROM THE BUILDING EDGE GOVERNS FOR ZONE 5, <br />COMPONENTS AND CLADDING <br />140 <br />Ult - ROOF NET UPLIFT SCHEDULE <br />_ <br />MAIN ROOF (NOMINAL) <br />ROOF <br />DEGREES <br />ZONE <br />EFFECTIVE WIND AREA <br />10 SQ, FT, <br />20 SQ. FT, <br />50 SQ, FT, <br />100 SQ, FT. <br />> 27 TO 45 <br />+32,3/-35,3 <br />PSF <br />+31,4/-33,5 PSF <br />+30.2/-31,1 PSF <br />+C 9,3/-29.3 PSF <br />> 27 TO 45 <br />2 <br />+32,3/-412 <br />PSF <br />+31.4/-39,4 PSF <br />+30,2/-37,1 PSF <br />+29,3/-35,3 PSF <br />> 27 TO 45 <br />+32.3/-41,2 <br />PSF <br />+31A/-39,4 PSF <br />+30,2/-37,1 PSF <br />+29,3/-35,3 PSF <br />NOTEi <br />ROOFING MATERIALS SHALL BE CONNECTED TO THE ROOF STRUCTURE TO RESIST <br />UPLIFT INDICATED IN THE NET UPLIFT SCHEDULE, <br />3'-0' FROM THE BUILDING EDGE GOVERNS FOR ZONE 3, <br />5 ft. <br />(:D <br />5 ft' <br />I O s <br />JOB ADDRFSS. <br />4408 Court St. <br />0 <br />4 f t. <br />0 <br />4 ft. �2 4 ft. <br />4 ft. �2 <br />� <br />0 <br />2 2 o <br />O 00 O 4 <br />4 ft. 4 ft. O � <br />O 4 ft. / 5 ft. �1 <br />� 5 ft. 4 ft. �2 <br />ROOF NAILING SCHEDULE <br />I HEREBY CERTIFY THAT I HAN'E REVIEWED THE A , AC D <br />DESICrN AND FOUND IT TO BE IN COMPLIANCE WI.`TI THE 2 14 <br />(5TH. EDITION) FLORIDA RESIDENTAL BUILDING CO E, <br />FEC 2014, & ASCE 7-10. J <br />AVID W. SMITH, PE <br />9909 VijAL.LASTON DR. LTCl PE 53608 <br />i A !352-521-0865 <br />4 ft. <br />4 ft. <br />• <br />WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED <br />TO ROOF FRAMING WITH 8d RING —SHANK NAILS AT 6" O.C. <br />AT EDGES AND 6" O.C. AT INTERMEDIATE FRAMING. <br />RING —SHANK NAILS SHALL HAVE THE FOLLOWING MINIMUM <br />DIMENSIONS: <br />1. 0,113 INCH SHANK DIAMETER. <br />2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER. <br />3. 16 TO 20 RINGS PER INCH. <br />4. 0.280 INCH FULL ROUND HEAD DIAMETER. <br />5. 2 INCH NAIL LENGTH. <br />FOR ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 UNITS <br />HORIZONTAL, AND GREATER, ONE LAYER OF UNDERLAYMENT <br />COMPLYING WITH ASTM D226 TYPE I OR II, ASTM D4869 <br />TYPE I OR II, OR ASTM D6757 SHALL BE APPLIED IN THE <br />FOLLOWING MANNER: <br />1. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO <br />AND STARTING FROM THE EAVE AND LAPPED 2 INCHES. <br />2. END LAPS SHALL BE OFFSET BY 6 FEET. <br />3. CORROSION RESISTANT FASTENERS ARE TO BE APPLIED ALONG THE <br />OVERLAP AT A MINIMUM SPACING OF 36" ON CENTER. <br />R905.2.4 ASPHALT SHINGLES <br />ASPHALT SHINGLES SHALL COMPLY WITH ASTM D225 OR <br />D3464. <br />ASPHALT SHINGLES SHALL BE RATED FOR INDICATED MIND <br />SPEED. <br />R905.2.4 ASPHALT SHINGLE FASTENERS <br />FASTENERS FOR ASPHALT SHINGLES SHALL BE GALVANIZED, <br />STAINLESS STEEL, ALUMINUM, OR COPPER ROOFING NAILS, <br />MINIMUM 12 gage SHANK WITH A MINIMUM g INCH DIAMETER <br />HEAD, ASTM F 1667, OF A LENGTT TO PENETRATE <br />THROUGH THE ROOFING MATERIALS AND A MINIMUM OF <br />INCH INTO THE ROOF SHEATHING. WHERE THE ROOF <br />SHEATHING IS LESS THAN 31'INCHES THICK THE FASTENERS <br />SLAA PENETRATE THROGH THE SHEATHING. FASTENERS <br />SHALL COMPLY WITH ASTM F 1667. <br />R905.2.6 ASPHALT SHINGLE ATTACHMENT <br />ASPHALT SHINGLES SHALL HAVE THE MINIMUM NUMBER OF FASTENERS <br />REQUIRED BY THE MANUFACTURER, BUT NOT LESS THAN FOUR <br />FASTENERS PER STRIP SHINGLE OR TWO PER INDIVIDUAL SHINGLE. <br />SCALE — NTS <br />dEET <br />S3, <br />a, <br />