My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
37827 Eiland Blvd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
37827 Eiland Blvd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:22:08 PM
Creation date
2/19/2025 8:01:37 AM
Metadata
Fields
Template:
Building Plans
Street #
37827
Location
Eiland Blvd
Contractor
SL2 Consultong LLC
Building Plans - Permit #
858
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UPDATED 11 /02/2020 <br />ALL WORK SHALL COMPLY WITH PREVAILING <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />ORDINANCES <br />REVIEW DATE Z <br />CITY OF ZEPHYRHILLS <br />PLAN EXAMINER—�� <br />CONSTRUCTION PLANS FOR <br />VA CLINIC <br />Eiland Blvd. <br />Zephyrhills, Florida <br />S1.1 <br />LOW FRAMING PLAN <br />S1.2 <br />HIGH FRAMING PLAN <br />S2.0 <br />SECTION <br />S2.1 <br />SECTION <br />S2.2 <br />SECTION <br />S2.3 <br />SECTION <br />STRUCTURAL DETAILS <br />53.0 <br />_ <br />S3.1 <br />STRUCTURAL DETAILS <br />STRUCTURAL DETAILS <br />STRUCTURAL DETAILS _ <br />S3.2 <br />S3.3 <br />_STRUCTURAL FABRICATION DETAILS_ <br />_S4.0 _ <br />S4.1 <br />STRUCTURAL FABRICATION DETAILS <br />S4.2 <br />STRUCTURAL FABRICATION DETAILS <br />AREA TABULATION <br />GROSS INTERIOR AREA 14,780 SO FT <br />LOBBY AREA 1,163 SO FT <br />NET BUSINESS AREA 13,617 SO FT <br />OCCUPANT LOAD <br />BUSINESS AREA 13,617 SOFT/ 100 = 137 <br />LOBBY AREA 1,163 SO FT / 15 = 78 <br />TOTAL OCCUPANT LOAD 215 <br />LAYOUT PAGE <br />TABLE <br />LABEL <br />TITLE <br />DESCRIPTION <br />COMMENTS <br />A-1 A <br />ABBREVIATIONS <br />A-2 <br />SITE PLAN REFERENCE <br />SEE CIVIL PLANS <br />A-3 <br />FLOOR PLAN ROOM NUMBERS <br />AND AREA USAGE <br />A-4 <br />DIMENSIONS & NOTES PLAN <br />A-5 <br />ROOM FINISH SCHEDULE <br />A-6 <br />DOOR SCHEDULE <br />A-7 <br />DOOR HARDWARE <br />A-8 <br />WALL TYPE PLAN <br />A-9 <br />WALL TYPES <br />A-10 <br />ELEVATIONS <br />A-11 <br />BUILDING SECTIONS <br />A-12 <br />FOUNDATION PLAN <br />A-13 <br />FIRST FLOOR FRAMING PLAN <br />A-14 <br />HIGH ROOF FRAMING PLAN <br />A-15 <br />STRUCTURAL DETAILS <br />A-16 <br />ADA DETAILS <br />A-17 <br />WALL SECTIONS & NOTES <br />A-18 <br />LGF FRAMING DETAILS <br />A-19 <br />FRAMING DETAILS <br />A-20 <br />DOOR ATTACHMENT DETAILS <br />A-21 <br />ROOM ELEVATIONS & <br />PRODUCT <br />APPROVALS <br />A-22 <br />ROOM ELEVATIONS <br />A-23 <br />REFLECTED CEILING PLAN <br />A-24 <br />LIFE SAFETY PLAN <br />A-25 <br />STRUCTURAL NOTES <br />A-26 <br />ROOFING DETAILS <br />A-27 <br />ROOFING DETAILS <br />A-28 <br />ROOFING DETAILS <br />A-29 <br />BUILDING ENTRY AREA <br />A-30 <br />ENTRY VIEWS <br />R1 <br />R2 <br />R3 <br />ROOM EQUIPMENT LAYOUTS <br />ROOM EQUIPMENT LAYOUTS <br />ROOM EQUIPMENT LAYOUTS <br />ROOM- EQUIPMENT LAYOUTS <br />ROOM EQUIPMENT LAYOUTS <br />ROOM EQUIPMENT LAYOUTS <br />ROOM EQUIPMENT LAYOUTS _ <br />CEILING LIFT INSTALLATION INSTRUCTIONS <br />CEILING LIFT INSTALLATION INSTRUCTIONS_ <br />MECHANICAL ELECTRICAL PLUMBING <br />STRUCTURALPLANS <br />R4 <br />R5 _ <br />R6 <br />R7 <br />R9 <br />R10 <br />MEP <br />S <br />THIS PLAN SHALL MEET ALL ENERGY REQUIREMENTS <br />OF THE FLORIDA BUILDING CODE 2017 6th Addition <br />BUILDING CODE SUMMARY <br />THESE PLANS HAVE BEEN PREPARED TO MEET THE MINIMUM REQUIREMENTS ESTABLISHED BY: <br />BUILDING CODE: FLORIDA BUILDING CODE 6th ADDITION 2017 <br />OSHA STANDARDS <br />Reference to Standards: <br />ACI- American Concrete Institute <br />ASTM- American Society for Testing Materials <br />NEC- National Electric Code <br />U.L.- Underwriter=s Laboratories, Inc. <br />CRSI- Concrete Reinforcing Steel Institute <br />BUILDING DATA <br />Building Height: 21' <br />Building Type: 213 Sprinkled <br />Occupancy: Business w/ assembly (Waiting Room) <br />No. of Stories: 1 <br />Gross Area: (SEE TABLES) <br />• Florida Building Code 6th Edition (2017) - Building <br />• Florida Building Code 6th Edition (2017) - Accessibility <br />• Florida Building Code 6th Edition (2017) - Test Protocols <br />• Florida Building Code 6th Edition (2017) - Mechanical <br />• Florida Building Code 6th Edition (2017) - Plumbing <br />• Florida Building Code 6th Edition (2017) - Fuel Gas <br />• Florida Fire Prevention Code <br />• (NFPA 101, NFPA 1, FL 44 RULES, FSS 633) <br />• NFPA 72 Fire Alarm Code <br />• NFPA 13 Fire Sprinkler Code <br />• NATIONAL CODES: <br />• NFPA 70 NATIONAL ELECTRICAL CODE <br />• UL Standard 181 (2005) <br />• ASTM E 96 (2013) <br />• ASCE 7 (2010)— with Errata dated January 11, 2011 <br />• ANSI/AHSRAE/ASHE Standard 170 (2013) <br />• UL Standard 1069 7th Edition (2007) <br />Building Codes and Standards for Leasing <br />The building will be designed, constructed and maintained in accordance with the most current <br />version of the codes and standards at time of award: <br />• All applicable State and Local Building Codes <br />• The Joint Commission <br />• The Facility Guidelines Institute Guidelines for Design and Construction of Health Care Facilities <br />• NFPA 99: Health Care Facilities Code <br />• Architectural Barriers Act Accessibility Standards (ABAAS)ln the absence of a State or Local Fire <br />Code - NFPA 101: Life Safety Code <br />• VA PG 18-14: Room Finishes, Door & Hardware Schedule — used to define room finish <br />materials, door sizes and types and hardware functionality. References to VA specifications need <br />not be followed. <br />• VA Signage Design Guide <br />U0 <br />ltampa <br />URBANoRDER.tampa, Inc. <br />5006 south elberon streot 33611 <br />813.832.5557 <br />HA2002460 <br />URBAMRDER.tampa, inc. <br />Thew plane are copyrighted and are subject to <br />copyright protection as an "amhitwund work" under <br />eectim 102 cd the cupyrlgM act 17 u. eA. ae <br />amended Decnmhet 1990 and known as arifilaclural <br />wales copyrglh: pro:sctan ac: of 1990 The <br />protector includes but a oct Lmdeo to the overall <br />ion as well as arrangement and co nposuon of <br />spaces and elamanls of IN designunder ouch <br />protec.Iido, unauthorized use; of lhuw plans, work a <br />home represented. con legalty resull in IN cossatbn <br />of cdnatruclon or buildings being w¢ed andlor <br />—bay compalsation to UR9AWDERItempe inc , <br />Florida m.gerroo. AA26002460 <br />ISSUE DATE <br />05/15/2019 <br />REVISIONS <br />N <br />d' <br />L0 <br />CM <br />CM <br />U <br />-0 <br />Z <br />En <br />O <br />U <br />3 <br />Q <br />Cn <br />W <br />'F <br />N <br />N <br />W <br />W <br />W <br />0 <br />0 <br />JOE TOPH <br />FL.,REG AR10095 <br />DATE. 1111912020 <br />DRWN <br />CHKD. <br />SCALE. <br />SHEETNUMBER <br />Aml <br />VAzhills 11/1912020 11:27.58 <br />AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.