PANEL 'SEC' <br />PANEL SEC <br />11/13/20 HERTZ <br />60 <br />AUTO CALCULATIONS <br />HI VOLTAGE <br />208 SYM RMS AMPS <br />22,000 <br />LOAD (VA) <br />7,701 <br />LOW VOLTAGE <br />120 BREAKER TYPE <br />MCB <br />DIVERSITY(VA) <br />0 <br />PHASE <br />3 MAIN LUG AMPS <br />60A MCB <br />25% C LOAD <br />68 <br />#WIRES <br />4 FED TOP/BOTTOM <br />TOP <br />TOTAL VA <br />7,770 <br />NEUTRAL <br />Y MOUNTING <br />SURFACE <br />TOTAL KVA <br />8 <br />GROUND BUS Y/N <br />Y NEMA TYPE <br />NEMA 1 <br />CONN AMPS <br />22 <br />GND WIRE Y/N <br />Y MANUFACTURER <br />SQUARE D <br />FACTOR AMPS <br />3 <br />WIRE THHN/THW <br />THWN PANEL TYPE <br />NQOD <br />TOTAL AMPS <br />25 <br />FROM <br />M <br />DESIGN AMPS <br />60 <br />NO.OF POLES <br />42 <br />MIN. AMPS <br />60 <br />% FACTOR <br />15 <br />BUSSING <br />COPPER <br />ISOLATED GND <br />N <br />X <br />CIR # BREAKER <br />CIRCUIT DESCRIPTION <br />L1 <br />L2 <br />L3 <br />1 20A-1 P <br />REC 102 A <br />D <br />360 <br />-- <br />- <br />3 20A-1 P <br />REC 102 B <br />D <br />- <br />360 <br />- <br />5 20A-1 P <br />REC 102 C <br />D <br />- <br />-- <br />360 <br />7 20A-1 P <br />REC 102 D <br />D <br />360 <br />- <br />- <br />9 20A-1 P <br />LTG 102 103 104 105 EF-1.4,1-5 <br />C <br />- <br />273 <br />- <br />11 20A-1P <br />REC COFFEE BREWER <br />D <br />- <br />- <br />1,200 <br />13 20A-1 P <br />REC GENERAL ARMORY <br />D <br />180 <br />- <br />-- <br />15 20A-1P <br />REC GENERAL SECURITY <br />D <br />-- <br />180 <br />-- <br />17 15A-3P <br />VAV-1.4 <br />V <br />-- <br />-- <br />636 <br />19 -- <br />- <br />V <br />636 <br />- <br />- <br />21 - <br />- <br />V <br />- <br />636 <br />- <br />23 <br />SPACE <br />- <br />- <br />0 <br />25 <br />SPACE <br />0 <br />- <br />- <br />27 <br />SPACE <br />---- <br />0 <br />- <br />29 <br />SPACE <br />- <br />- <br />0 <br />31 <br />SPACE <br />0 <br />-- <br />- <br />33 <br />SPACE <br />- <br />0 <br />- <br />35 <br />SPACE <br />- <br />- <br />0 <br />37 <br />SPACE <br />0 <br />- <br />-- <br />39 <br />SPACE <br />- <br />0 <br />- <br />41 <br />SPACE <br />-- <br />- <br />0 <br />CIR # <br />BREAKER <br />CIRCUIT DESCRIPTION <br />L1 <br />L2 <br />L3 <br />2 <br />SPACE D <br />360 <br />-- <br />- <br />4 <br />SPACE D <br />- <br />360 <br />- <br />6 <br />20A-1P <br />SECURITY SYSTEM (BY OTHERS) <br />- <br />- <br />1,200 <br />8 <br />20A-1P <br />FACP <br />600 <br />- <br />- <br />10 <br />SPACE <br />- <br />0 <br />- <br />12 <br />SPACE <br />- <br />- <br />0 <br />14 <br />SPACE <br />0 <br />- <br />- <br />16 <br />SPACE <br />- <br />0 <br />- <br />18 <br />SPACE <br />- <br />- <br />0 <br />20 <br />SPACE <br />0 <br />- <br />- <br />22 <br />SPACE <br />- <br />0 <br />- <br />24 <br />SPACE <br />- <br />- <br />0 <br />26 <br />SPACE <br />0 <br />- <br />- <br />28 <br />SPACE <br />- <br />0 <br />- <br />30 <br />SPACE <br />- <br />- <br />0 <br />32 <br />SPACE <br />0 <br />- <br />- <br />34 <br />SPACE <br />- <br />0 <br />- <br />36 <br />SPACE <br />- <br />- <br />0 <br />38 <br />30A-3P <br />TVSS <br />0 <br />- <br />40 <br />- <br />- <br />-- <br />0 <br />- <br />42 <br />- <br />- <br />- <br />- <br />0 <br />O RISER KEY NOTES <br />1. UTILITY COMPANY TRANSFORMER. COORDINATE LOCATION WITH UTILITY COMPANY AND <br />OWNER, AND STAKE OUT AGREED UPON LOCATION. PREPARE TRANSFORMER BASE <br />PER UTILITY COMPANY REQUIREMENTS, STUB UP CONDUIT AND PROVIDE PRE -CAST <br />OR CAST IN PLACE PAD PER UTILITY COMPANY REQUIREMENTS. <br />2. PROVIDE SECONDARY OR FEEDER WIRING AS SHOWN. SEE FEEDER SCHEDULE. <br />3. PROVIDE METER EQUIPMENT GROUP APPROVED CT METER OUTSIDE OF MEP ROOM. <br />METER SHALL MEET ALL LOCAL REQUIREMENTS AND CERTIFICATIONS. BOND PER NEC <br />REQUIREMENTS. <br />4. PROVIDE 1200A RATED CT CABINET. <br />5. PROVIDE 1200A NEMA 3R 208/120V 30. 4W FUSED DISCONNECT. <br />6. PROVIDE NEC ARTICLE 250 COMPLIANT GROUNDING ELECTRODE SYSTEM. PROVIDE A <br />#3/0 THWN COPPER MAIN SERVICE ELECTRODE GROUNDING CONDUCTOR IN CONDUIT <br />FROM METER CENTER TO GROUND RODS WITH NAMEPLATE LABELED INSPECTION <br />WELLS: PROVIDE THREE COPPER CLAD GROUND RODS, SPACED AND ARRANGED PER <br />NEC ARTICLE 250.53, 5/8" DIA X 10'-0" LONG. DRIVE ADDITIONAL GROUND RODS <br />TO ENSURE RESISTANCE IS 20 OHMS OR LESS. MEASURE RESISTANCE AND PROVIDE <br />REPORT TO OWNER AND ENGINEER. CONNECT TO BUILDING STEEL, CONCRETE <br />ENCASED ELECTRODE ('CEE') (IF NO VAPOR BARRIER PRESENT), AND METAL WATER <br />LINES VIA #3/0 THWN CU WIRE. IF CEE IS PROVIDED, PROVIDE INSPECTION WELL <br />OR METHOD TO INSPECT AND MONITOR CONNECTION. <br />7. PROVIDE NEMA 3R GENERATOR DOCKING STATION FOR ATS TO PROVIDE A LOCATION <br />FOR OWNER TO CONNECT A PORTABLE GENERATOR, TRYSTAR GENERATOR DOCKING <br />STATION OR EQUAL. PROVIDE PAD FOR DOCKING STATION, SECURE TO STRUCTURE <br />AND/OR PAD. <br />8. PROVIDE 3-POLE 120/208V 1200A ATS, ASCO SERIES 300 OR APPROVED EQUAL. <br />WHEN GENERATOR IS NOT PRESENT, ATS SHALL BE INHIBITED FROM TRANSFERRING <br />LOAD. <br />9. PROVIDE 120/208V 30, 4W NEMA 1 1200A MCB PANEL 'Mo. SEE PANEL SCHEDULE. <br />SQUARE D I -LINE HCR-U OR APPROVED EQUAL. <br />10. PROVIDE SERVICE ENTRANCE RATED, UL 3RD EDITION LISTED SURGE ARRESTOR <br />(TVSS). INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />11. PROVIDE PANEL WITH INDICATED CHARACTERISTICS. SEE PANEL SCHEDULES AND <br />FEEDER SCHEDULE. <br />12. PROVIDE UL 3RD EDITION LISTED SURGE ARRESTOR (TVSS). INSTALL PER <br />MANUFACTURER'S RECOMMENDATIONS. <br />ass <br />ELECTRICAL SCOPE <br />1. PROVIDE ALL EQUIPMENT AND MATERIAL SHOWN ON DRAWINGS AND IN <br />SPECIFICATIONS, WHETHER OR NOT NOTES INCLUDE THE WORDS 'PROVIDE' OR 'ALL'. <br />2. PROVIDE ELECTRICAL FIXTURES, DEVICES AND EQUIPMENT SHOWN AND REQUIRED <br />MATERIALS, LABOR AND EQUIPMENT FOR A COMPLETE AND OPERATIONAL FACILITY. <br />3. POWER: COORDINATE WITH UTILITY COMPANY TO PROVIDE ELECTRICAL SERVICE. <br />PROVIDE SECONDARY WIRING, MAIN ELECTRICAL PANEL, FEEDERS, BRANCH PANELS, <br />BRANCH CIRCUITS, AUTOMATIC TRANSFER SWITCH, OVER CURRENT PROTECTION <br />DEVICES, BREAKERS, EQUIPMENT CONNECTIONS, SURGE SUPPRESSION AND OTHER <br />DEVICES AS SHOWN. PROVIDE PERMANENT LABELS ON ALL DEVICE COVERS WITH <br />CIRCUIT NUMBER. DEVICE COLOR AND COVER PLATES SHALL BE SELECTED BY <br />ARCHITECT. PROVIDE ENGRAVED NAMEPLATES ON ALL EQUIPMENT WITH ITEM NAME <br />AND CIRCUIT NUMBER. <br />4. LIGHTING: PROVIDE A COMPLETE LIGHTING SYSTEM INCLUDING LIGHT FIXTURES, <br />BRANCH CIRCUITS, BREAKERS, SWITCHES, AND CONTROLS. OCCUPANCY AND VACANCY <br />SENSORS SHALL BE PROVIDED TO COMPLY WITH ENERGY CODE REQUIREMENTS. <br />EMERGENCY LIGHTING IS PROVIDED BY EMERGENCY BATTERIES INTEGRAL WITHIN <br />DESIGNATED FIXTURES. AUTOMATIC DAYLIGHT CONTROLS ARE PROVIDED BY DAYLIGHT <br />SENSORS WITHIN EACH DAYLIGHT ZONE. PROVIDE ROOM CONTROLLERS, POWER <br />SUPPLIES AND ALL OTHER REQUIRED EQUIPMENT, MATERIALS AND PROGRAMMING <br />REQUIRED FOR A COMPLETE AND FUNCTIONAL LIGHTING AND LIGHTING CONTROL <br />SYSTEM. <br />5. DATA: PROVIDE DATA SYSTEM AS SHOWN ON PLANS. <br />6. FIRE ALARM SYSTEM: PROVIDE A COMPLETE SYSTEMS AS SHOWN. <br />7. SECURITY: SECURITY CAMERAS, ACCESS CONTROL AND SECURITY INTRUSION <br />DETECTION: COMPLETE SYSTEMS (SECURITY CAMERA, ACCESS CONTROL AND <br />SECURITY INTRUSION DETECTION) SHALL BE PROVIDED. THE INFORMATION ON THE <br />PLANS IS DIAGRAMMATIC AND PROVIDED FOR LAYOUT COORDINATION PURPOSES. <br />SHOP DRAWINGS SHALL BE PROVIDED FOR LOW VOLTAGE PERMITTING AND <br />INSTALLATION WILL BE PROVIDED BY THE DEVELOPER'S SUB -CONTRACTORS. THE <br />SHOP DRAWINGS SHALL SHOW ALL DEVICE LOCATIONS, WIRING, POWER SOURCES, <br />EQUIPMENT LOCATIONS AND INSTALLATION REQUIREMENTS. CUT SHEET FOR <br />EQUIPMENT WILL BE PROVIDED, AS WELL AS CALCULATIONS FOR ANY BATTERY <br />BACKUP REQUIREMENTS. SYSTEMS SHALL BE INSTALLED, TESTED AND CONNECTED TO <br />OWNER DESIGNATED MONITORING SERVICES (IF MONITORING IS APPLICABLE OR <br />REQUIRED). SYSTEMS NOT SHOWN IN PLANS, VERIFY REQUIREMENTS: NURSE CALL <br />OR EXAM ROOM 'IN USE' LIGHTS. <br />8. WORKMANSHIP FOR ALL ELECTRICAL SYSTEMS SHALL BE NEAT AND PROFESSIONAL <br />AND SHALL COMPLY WITH CURRENT NECA/NEIS STANDARDS. <br />F3 <br />CT NORMAL <br />O O CABINET POWER --------- -- <br />MAIN QUICK CONNECT/ <br />UTILITY PROVIDED M NEMA 3R DISCONNECT GENERATOR <br />NEMA 3R DOCKING STATION <br />120/208 VOLT - - O5 <br />TRANSFORMER; 0 1200A <br />AVAILABLE FAULT CURRENT FUSES <br />(AFC) CALCULATED USING: 1200A S2 120/208V G3 <br />120/208V 30,4W <br />Z=1.6%, POWER FACTOR = .9, 30,4W OWNER PROVIDED <br />AND 300kVA: PORTABLE <br />AFC = 57,828 AMPS. GENERATOR <br />SCCR=65KA CABLES <br />INSTALLED HERE, <br />BY OTHERS <br />b O2 TYPICAL <br />L-------------------------J <br />MEP ROOM SECURITY SW AREA NW AREA SE AREA SHARED NW AREA <br />r------------------------------- --------------------------------------- --------� <br />- _---_--------------------------- ----- ------ <br />F4 I r---------------- � 2 TYPICAL I <br />----------- ----- ----- <br />1l l f =__ __ ______ - -- 1 I I I <br />__l I I I F9 I <br />ram-- ---� IIIIII I I F6 I F7 I F8 I I <br />I I IIIIII F5 I 10 I I I I I <br />ATS MAIN PANEL PANEL PANEL PANEL PANEL PANEL <br />PANEL 'M' 'NE' 'SEC' 'SW' 'NW' 'SE' 'NW2' <br />NEMA 1 <br />NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 NEMA 1 <br />(D SPACE <br />POLE 42 POLE 72 POLE 72 POLE 72 POLE 42 POLE <br />(DSPACE SPACE SPACE SPACE SPACE SPACE <br />1200A <br />120/208V 1200A MCB 11 11 11 11 11 11 <br />30,4W 120/208V 200A MCB 60A MCB 200A MCB 200A MCB 200A MCB 60A MCB <br />30,4W 120/208V 120/208V 120/208V 120/208V 120/208V 120/208V <br />30,4W 34,4W 30,4W 30.4W 30,4W 30,4W <br />a a a 12 a 12 a 12 a <br />in V Ln LLn <br />10 12 12 12 <br />GENERAL <br />NOTES <br />1. <br />WORK SHALL MEET OR EXCEED REGULATORY <br />11. CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS AND <br />NAMEPLATES ATTACHED TO EQUIPMENT BY STAINLESS <br />RECEPTACLES FOR SECURITY PANELS, HVAC EMS PANELS, <br />REQUIREMENTS, INCLUDING LATEST EDITION OF THE NFPA <br />INSPECTIONS. <br />STEEL SCREWS. <br />COMPUTER OUTLETS, SOUND / INTERCOM SYSTEM AND <br />101 (LIFE SAFETY CODE), THE KENTUCKY BUILDING CODE <br />CABLE TV HEAD END EQUIPMENT AND TV RECEPTACLES <br />FIRST EDITION (2018), THE NATIONAL ELECTRICAL CODE <br />12. EXPOSED EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED <br />18. WIREWAYS, PULLBOXES, OUTLETS AND JUNCTION BOXES <br />WITH CORD & PLUG. <br />2014, AND LOCAL REQUIREMENTS & BUILDING CODES. <br />STEEL. ALL EXPOSED INTERIOR CONDUIT SHALL BE RIGID <br />SHALL BE PROPERLY SIZED PER THE NATIONAL <br />GALVANIZED STEEL OR EMT. MC CABLE IS ALLOWABLE <br />ELECTRICAL CODE. ALL PULLBOXES AND OUTLET BOXES <br />28. BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR NO <br />2. <br />EQUIPMENT, FIXTURES, SWITCHES, STARTERS, CONTACTORS, <br />WHERE CONCEALED AND ALLOWED BY CODE. CONDUIT <br />SHALL BE PLAINLY COLOR CODED AND HAVE WIRING <br />MORE THAN 3% VOLTAGE DROP AT THE FARTHEST POINT. <br />CONTROLS, DEVICES, CONNECTIONS, BOXES, MOUNTING <br />INSTALLED BELOW SLAB OR UNDERGROUND MAY BE <br />TAGGED TO INDICATE PANEL AND CIRCUIT NUMBERS. <br />20 AMPERE BRANCH CIRCUITS SHALL HAVE MINIMUM SIZE <br />SUPPORTS, HARDWARE, WIRE, CONDUIT & ACCESSORIES <br />SCHEDULE 40 PVC OR RIGID GALVANIZED STEEL PAINTED <br />#10 COPPER HOMERUN WIRING FOR CIRCUITS OVER 57' <br />SHALL BE PER PLANS AND SPECIFICATIONS FOR <br />WITH HEAVY COAT OF BITUMASTIC PAINT (3/4" MINIMUM). <br />19. DISCONNECT SWITCHES SHALL BE SQUARE D, SIEMENS, <br />LONG & #8 COPPER HOMERUN WIRING FOR CIRCUITS <br />COMPLETE AND OPERATING ELECTRICAL SYSTEMS. <br />CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. <br />GENERAL ELECTRIC OR CUTLER HAMMER SAFETY <br />OVER 150' LONG. WHERE BRANCH CIRCUITS AND FEEDER <br />CONCEALED CONDUIT IN WALLS AND CEILINGS SHALL BE <br />SWITCHES. SWITCHES SHALL BE HEAVY DUTY AND RATED <br />CIRCUITS ARE OVERSIZED FOR VOLTAGE DROP, ENSURE <br />3. <br />CIRCUIT NUMBERS INDICATED ON THE DRAWINGS ARE FOR <br />EMT. EMT FITTINGS SHALL BE DIE CAST SET SCREW <br />FOR THE PROPER VOLTAGE. SWITCHES SHALL BE RATED <br />LUGS AND OTHER TERMINALS FOR MAIN CIRCUIT <br />REFERENCE USE, CONTRACTOR TO BALANCE THE LOADS <br />TYPE AT DRY INTERIOR LOCATIONS. EMT FITTINGS AT <br />AS INDICATED ON THE DRAWINGS FOR SIZE, NUMBER OF <br />BREAKERS, BRANCH CIRCUIT BREAKERS, DISCONNECT <br />IN ALL PANELS IN WHICH WORK IS PERFORMED. <br />DAMP, OR WET LOCATIONS SHALL BE DIE CAST <br />POLES AND TYPE ENCLOSURE. <br />SWITCHES, OR ANY OTHER EQUIPMENT WITH LUGS FOR <br />MAINTAIN COMPLETE AS -BUILT DRAWINGS. PROVIDE <br />COMPRESSION RAIN -TIGHT TYPE. WIRING (POWER, <br />WIRING TERMINATION ARE LARGE ENOUGH TO TERMINATE <br />ELECTRONIC AS -BUILT DRAWINGS AT COMPLETION OF <br />LIGHTING, FIRE ALARM) SHALL BE IN CONDUIT. <br />20. FUSES SHALL BE BUSSMAN CURRENT LIMITING TYPE. <br />THE OVERSIZED WIRING. <br />PROJECT. ELECTRONIC SET OF DRAWINGS WILL BE <br />PROVIDED FOR USE TO UPDATE THROUGHOUT PROJECT. <br />13. RECESSED LIGHTING FIXTURES SHALL HAVE THERMAL <br />21. LETTER INSIDE OR ADJACENT TO FIXTURE SYMBOL <br />29• DISPOSE OF LAMPS, BALLASTS, & OTHER HAZARDOUS <br />PROTECTION. PROVIDE A FIXTURE SUPPORT AT EACH <br />INDICATED TYPE - SEE FIXTURE SCHEDULE. <br />MATERIALS IN ACCORDANCE WITH FEDERAL, STATE, LOCAL, <br />4. <br />PROVIDE ENGRAVED NAMEPLATES FOR ALL ELECTRICAL <br />CORNER FOR ALL LAY -IN LIGHT FIXTURES, OR PROVIDE <br />& EPA REGULATIONS. <br />EQUIPMENT. <br />UL LISTED FIXTURE CLIPS AND REQUIRED MOUNTING <br />22. FOR EXACT LOCATIONS OF INTERIOR LIGHTING FIXTURES, <br />HARDWARE & ACCESSORIES. DRIVERS AND BALLASTS <br />SEE ARCH. REFLECTED CEILING PLANS. <br />30. MOTOR STARTERS, SAFETY SWITCHES, VARIABLE SPEED <br />5. <br />PROVIDE REQUIRED CONDUIT & CABLE PENETRATIONS <br />SHALL BE FUSED. <br />DRIVES, RELAYS, MOTOR CONTROL CENTER, MDP'S, <br />THROUGH PARTITIONS, WALLS, FLOORS, SLABS & ROOFS, <br />23. PROVIDE TELEPHONE/DATA OUTLETS WITH WIRING BACK <br />SWITCHBOARDS, PANELBOARDS, CONTACTORS, & ALL <br />WITH APPROVED FIRE SEALANT COMPOUND. <br />14. PROVIDE GREEN GROUND WIRE IN EACH RACEWAY, SIZE <br />TO TELEPHONE BOARD AND NETWORK SERVER. <br />OTHER ELECTRICAL EQUIPMENT, SHALL BE OF THE SAME <br />WIRE IN ACCORDANCE WITH TABLE 250.122 OF THE NEC. <br />MANUFACTURER UNLESS PROVIDED AS ELECTRICAL <br />6. <br />CONDUCTORS SHALL BE COPPER, 600 VOLT WITH <br />24. WHERE RECEPTACLES ARE INSTALLED CLOSER THAN 72" <br />EQUIPMENT ON APPROVED FACTORY FABRICATED <br />MINIMUM SIZE OF #12 AWG THWN / THHN, UNLESS <br />15. PANELBOARDS SHALL BE CIRCUIT BREAKER TYPE AS <br />FROM EDGE OF SINK OR LAV, RECEPTACLE SHALL BE OF <br />EQUIPMENT, SUCH AS CHILLER STARTERS, ROOF TOP <br />OTHERWISE SPECIFIED. WIRE SIZES OF #10 AND LARGER <br />MANUFACTURED BY SQUARE D, SIEMENS, GENERAL <br />THE GROUND FAULT CIRCUIT INT. TYPE, OR SERVED BY A <br />UNITS, CONDENSING UNITS, ETC. <br />SHALL BE STRANDED. <br />ELECTRIC, OR CUTLER HAMMER, OR AS NOTED. <br />GFCI BREAKER. <br />PANELBOARDS SHALL HAVE A HINGED LOCKING DOOR. <br />31. PROVIDE FLEXIBLE CONDUIT & WIRING CONNECTION TO <br />7. <br />EQUIPMENT SHALL BE RATED FOR MAXIMUM AVAILABLE <br />PANELS RATED 600 AMPS AND LARGER SHALL HAVE <br />25. EXTERIOR RECEPTACLES SHALL BE WP GFCI TYPE WITH <br />MOTORS &VIBRATING EQUIPMENT. <br />VOLTAGE AND GROUND FAULT CURRENT. ALL EQUIPMENT <br />HINGES ON THE COVER SO THAT THE COVER IS <br />WP WHILE IN USE COVER. PROVIDE RECEPTACLE AT <br />SHALL BE TESTED BY A NATIONAL TESTING LAB. <br />SUPPORTED AND MAY SWING TO THE SIDE WHEN THE <br />HVAC EQUIPMENT. <br />32. OUTDOOR EQUIPMENT, CONDUIT & CONNECTIONS SHALL <br />COVER BOLTS ARE REMOVED. <br />BE WEATHERPROOF. <br />8. <br />CONTRACTOR SHALL COORDINATE ELECTRICAL <br />26. IN ADDITION TO THE LEGEND THE CONTRACTOR SHALL <br />REQUIREMENTS AND MAKE FINAL CONNECTIONS OF <br />16. PROVIDE A TYPEWRITTEN CIRCUIT DIRECTORY WITH <br />COORDINATE EXACT LOCATION OF OUTLETS AND DEVICES <br />33. PROVIDE A DEDICATED NEUTRAL FOR ALL CIRCUITS. <br />EQUIPMENT FURNISHED BY OTHER TRADES. <br />PROTECTIVE COVERING. WIRES IN PANEL SHALL BE <br />WITH ARCHITECTURAL INTERIOR ELEVATIONS & CABINET <br />TAGGED WITH CIRCUIT NUMBER. CIRCUIT BREAKERS FOR <br />WORK. <br />34. WHERE GFCI RECEPTACLES ARE SHOWN, A SEPARATE GFCI <br />9. <br />CONTRACTOR SHALL MAINTAIN A COMPLETE TEMPORARY <br />MECHANICAL EQUIPMENT SHALL BE HACR TYPE. <br />DEVICE SHALL BE PROVIDED, THEY SHALL NOT BE <br />POWER SYSTEM DURING CONSTRUCTION. COORDINATE ALL <br />27. PROVIDE SERVICE RATED LIGHTNING SURGE ARRESTOR & <br />SLAVED. <br />POWER OUTAGES & CHANGEOVERS WITH THE OWNER. <br />17. SWITCHBOARDS, MCC'S, PANELBOARDS, CIRCUIT BREAKERS, <br />SERVICE RATED TVSS SURGE PROTECTION AT THE MAIN <br />TRANSFORMERS, DISCONNECT SWITCHES, MOTOR STARTERS <br />SERVICE ENTRANCE. PROVIDE SUBPANEL RATED TVSS <br />35. PRIOR TO COMPLETION OF THE PROJECT, PROVIDE <br />10. <br />CONTRACTOR SHALL GUARANTEE MATERIALS AND <br />AND OTHER ELECTRICAL APPARATUS INSTALLED FOR THE <br />SURGE PROTECTION AT PANELS PROVIDING POWER TO <br />WRITTEN CERTIFICATION FOR EACH LIFE SAFETY AND LOW <br />WORKMANSHIP FOR ONE YEAR. <br />OPERATION OF ANY EQUIPMENT SHALL BE PROPERLY <br />HVAC EQUIPMENT, MOTORS, COMPUTERS AND ELECTRONIC <br />VOLTAGE ELECTRICAL SYSTEM. <br />IDENTIFIED WITH ENGRAVED LAMINATED PLASTIC <br />EQUIPMENT. PROVIDE SURGE PROTECTION TYPE <br />f�SniF^�1 <br />U i( Ss yA <br />u�r. _cut! Ib. ron t t ",a9i <br />The- plans ere coppphted end» subject 10 <br />copyrvl pmwbw n - YrchRa t work' under <br />sac 102 of as copyright as 17 u a.o.a <br />emend.d Doo-ber 1990 and known-.."eclur.l <br />woke capydghl probacbm nt of 1990. The <br />protschon inoluOn bulls not bmtso d to the nnab <br />forma well ee arrangement and compoaPoon d <br />spoon and elements of the deignunder such <br />p"'c""' uns.ftmad u-of dross plena, work or <br />home repr-ent d, an lagelly muh in Me cn-ban <br />of conal-bon or bulldmps being seed endo <br />monat" compen-bon to 1.1119MloRDERRemps m , <br />Flonde regabsbon AA21=460 <br />ISSUE DATE <br />09/21 /2020 <br />REVISIONS <br />as <br />m <br />- <br />- <br />m <br />O <br />rc <br />-soLL <br />L <br />c <br />V, <br />CL,- <br />W <br />-_ <br />N <br />Q` <br />N <br />� <br />� <br />con <br />/ <br />a) <br />CO <br />N <br />FEEDER SCHEDULE <br />Q <br />V <br />-' <br />w <br />(n <br />V IT <br />W <br />J <br />W <br />AVAILABLE <br />AVAILABLE <br />AMPERE INTERUPT <br />DISTANCE <br />VOLTAGE <br />SINGLE OR <br />CONDUIT <br />RISER <br />ID <br />FROM <br />TO <br />AMPERAGE <br />(AMPS) <br />LOAD <br />(AMPS) <br />FAULT CURRENT <br />(AFC) L-L (AMPS) <br />FAULT CURRENT <br />(AFC) L-N (AMPS) <br />CAPACITY RATING <br />(AIC RATING) <br />(HORIZ+VERY) <br />(FEET) <br />DROP <br />N <br />THREE PHASE <br />10 / 30 <br /># OF <br />SETS <br />CONDUCTOR <br />MATERIAL <br />PHASE CONDUCTORS <br />QTY SIZE <br />NEUTRAL CONDUCTOR <br />QTY SIZE <br />GROUND EGC/GEC <br />QTY GEC/EGC SIZE <br />SIZE <br />(PER SE <br />CONDUIT <br />MATERIAL <br />S1 <br />UTIL <br />CT CABINET <br />1,200 <br />955 <br />48,262 <br />41,404 <br />65,000 <br />40 <br />0.37% <br />3 <br />4 <br />CU <br />3 <br />#400 KCM <br />1 <br />#400 KCM <br />1 <br />GEC <br />#3/0 <br />3" <br />PVC <br />S2 <br />CT CABINET <br />MAIN D/C <br />1,200 <br />955 <br />47,112 <br />39,737 <br />65,000 <br />5 <br />0.43% <br />3 <br />4 <br />CU <br />3 <br />#400 KCM <br />1 <br />#400 KCM <br />1 <br />EGC <br />#4/0 <br />3" <br />EMT <br />F3 <br />MAIN D/C <br />MTS N <br />1,200 <br />955 <br />46,014 <br />38,199 <br />65,000 <br />5 <br />0.48% <br />3 <br />4 <br />CU <br />3 <br />#400 KCM <br />1 <br />#400 KCM <br />1 <br />EGC <br />#4/0 <br />3" <br />EMT <br />G3 <br />GDS <br />MTS SB <br />1,200 <br />955 <br />34,667 <br />28,865 <br />65,000 <br />5 <br />0.62% <br />3 <br />4 <br />CU <br />3 <br />#400 KCM <br />1 <br />#400 KCM <br />1 <br />EGC <br />#4/0 <br />3" <br />1 EMT <br />F4 <br />MTS N <br />M <br />1,200 <br />955 <br />42,887 <br />34,071 <br />65,000 <br />15 <br />0.65% <br />3 <br />4 <br />CU <br />3 <br />#350 KCM <br />1 <br />#350 KCM <br />1 <br />EGC <br />#3/0 <br />3" <br />EMT <br />F5 <br />M <br />NE <br />200 <br />120 <br />37,652 <br />27,903 <br />42,000 <br />5 <br />0.70% <br />3 <br />1 <br />CU <br />3 <br />#3/0 <br />1 <br />#3/0 <br />1 <br />EGC <br />#6 <br />2" <br />EMT <br />F6 <br />M <br />SW <br />200 <br />123 <br />9,582 <br />5,220 <br />22,000 <br />125 <br />1.85% <br />3 <br />1 <br />CU <br />3 <br />#3/0 <br />1 <br />#3/0 <br />1 <br />EGC <br />#6 <br />2" <br />EMT <br />F7 <br />M <br />NW <br />200 <br />187 <br />11,237 <br />6,219 <br />22,000 <br />130 <br />2.09% <br />3 <br />1 <br />CU <br />3 <br />#250 KCM <br />1 <br />#250 KCM <br />1 <br />EGC <br />#4 <br />2 1/2" <br />EMT <br />F8 <br />M <br />SE <br />200 <br />111 <br />13,300 <br />7,510 <br />22,000 <br />80 <br />1.34% <br />3 <br />1 <br />CU <br />3 <br />#3/0 <br />1 <br />#3/0 <br />1 <br />EGC <br />#6 <br />2" <br />EMT <br />F9 <br />M <br />NW2 <br />60 <br />12 <br />1,858 <br />943 <br />22,000 <br />150 <br />1.34% <br />3 <br />1 <br />CU <br />3 <br />#6 <br />1 <br />#6 <br />1 <br />EGC <br />#10 <br />1" <br />EMT <br />F10 <br />M <br />SEC <br />60 <br />25 <br />4,361 <br />1 2,264 <br />22,000 <br />60 <br />1.23% <br />3 <br />1 <br />CU <br />3 <br />#6 <br />1 1 <br />1 #6 <br />1 <br />EGC <br />#10 <br />1" <br />EMT <br />NOTES: <br />1. LENGTHS ARE FOR FAULT CURRENT AND VOLTAGE DROP CALCULATIONS ONLY. CONTRACTOR SHALL FIELD VERIFY ALL CONDUIT <br />2. SELECTED FEEDERS PHASE AND EGC CONDUCTORS ARE OVERSIZED FOR VOLTAGE DROP. <br />ROUTES AND LENGTHS. <br />LUMINAIRE SCHEDULE <br />MARK <br />VOLTAGE <br />LAMP TYPE <br />WATTS <br />MOUNTING <br />DIMMING <br />DESCRIPTION <br />L1(EM) <br />METALUX CRUZE 24CZ2 40 UNV (EL7W) L835 CD1 <br />UNV <br />LED <br />40 <br />GRID LAY -IN <br />0-1 OV <br />2'X4' LED GRID LAY -IN FLAT PANEL, 0-1 OV DIMMING; (WITH EMERGENCY BATTERY) <br />L2 <br />METALUX 4VVNLED LD4 32SL F UNV CD1 <br />UNV <br />LED <br />29 <br />CEILING SURFACE <br />0-10V <br />SURFACE MOUNTED STRIP LIGHT FOR UTILITY ROOMS <br />L3(EM) <br />HALO COMMERCIAL HC6 20 D010 (REM7) HM6 12 835 61 MD X 61 PS WD W <br />UNV <br />LED <br />21 <br />RECESSED CEILING <br />0-10V <br />RECESSED 6 INCH LED (WITH EMERGENCY BATTERY) <br />L4 (EM) <br />HALO COMMERCIAL HC6 20 DO 10 HM6 12 835 61 MD X 61 PS WD W <br />UNV <br />LED <br />21 <br />RECESSED CEILING <br />0-10V <br />RECESSED 6 INCH LED, WET LOCATION LISTED (WITH EMERGENCY BATTERY) <br />L5(EM) <br />CORONET LS4 LED UPDN 4 35 IN-LTG1 D-LTG1 UNV DB WAC IN -SD D-SD (EM 120V) <br />UNV <br />LED <br />36 <br />PENDANT <br />0-10V <br />PENDANT LIGHT, 4' DECORATIVE STRIP (WTH EM BATTERY) <br />L6 <br />METALUX 2 BCLED LD4 20SL F UNV 835 CD1 <br />UNV <br />LED <br />23 <br />WALL <br />0-1 OV <br />WALL MOUNTED VANITY LIGHT <br />L8 (EM) <br />COOPER INVUE ENC-E02-LED-El-BL3-XX-8030-BBB120-DIM <br />UNV <br />LED <br />52 <br />EXTERIOR WALL <br />0-1 OV <br />WALL MOUNTED EXTERIOR LIGHT, COLOR TEMPERATURE AND FINISH BY ARCHITECT. <br />X <br />SURELITE LPX7 SD <br />UNV <br />LED <br />10 <br />WALL/CEILING <br />NO <br />LED EXIT LIGHT WITH BATTERY, OPTIONS SELECTED BYARCHITECT <br />NOTES: <br />1. VERIFYCOLOR TEMPERATURE OF ALL LAMPS PRIOR TO ORDERING. ALL LUMINAIRES SHALL BE SAME COLOR TEMP UNLESS DIRECTED OTHERVVISE. <br />2. PROVIDE PROPER SUPPORT FOR ALL LUMINAIRES. <br />3. PROVIDE FUSES FOR ALL LUMINAIRES. <br />4. PROVIDE LAMPS FOR ALL FIXTURES. <br />DATE: 11 /13/2020 <br />DRWN: J.D.E. <br />CHKD: J.J.H. <br />SCALE: 1 /8" = V-0" <br />SHEET NUMBER <br />E�6 <br />2:4 <br />1-0 <br />