Laserfiche WebLink
i <br />ROOF FRAMING PLAN <br />SCALE: )14"=1'-0" <br />SYMETRICAL <br />NOTE: <br />• SEE D1 SHEET FOR TYPICAL ROOF FRAMING DETAILS <br />• SEE SHEET 10 FOR BUILDING ROOF LAYOUT <br />I SPECIAL CONNECTIONS I <br />S1 :(2) HTWM20 W/ (4) 1/4"x1 3/4" W.BOLTS TO CMU & (8) 10dx1 1/2 NAILS <br />:SIMPSON LGT3SDS2.5 W/ (12) SDS 1/4"x2 1/2" TO GIRDER & (4) 3/8"x5 TITEN HD TO WALL PROVIDE 2x6x1'-O" <br />S2 #2 SYP SCAB @ BRG. W/ MIN. (8) 12d NAILS TO GIRDER BOTTOM CHORD <br />S3 :USP RFUS (2) (12) WS3 W/ (4) 3/4"x6" WEDGE BOLTS <br />S4 :SIMPSON (1) FGTR w/ (18) WS3 w/ (2) 1/2"x5" TITEN HD. <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 112" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2% 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH, / (26) 10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />— <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />100011080** <br />--- <br />8 - 10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />"X" HTS 20 1310 1245 24-1 Od x 1 1/2" HTW20 1530 1285 24-10d x 1 112" <br />SP1 555 535 1 10-10d SPT22 735 8-10d <br />SP2 1010 605 1 12 - 10d SPT24 1090 12 - 10d <br />HCP2 1 590 555 1 12-1 Old x 1 1/2" HHCP2 680 570 1 (20)1 Old x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(B) <br />(A) <br />I OR 2 PLY <br />'ARRIER <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />VA <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS wO (A) <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE S-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />(2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />OR <br />E AS <br />M Li <br />CONT LEDGER <br />0. <br />0 <br />Cca <br />0 0 <br />0 <br />? <br />IL M <br />U) <br />V) <br />2 <br />Mj <br />Q <br />CCD <br />ao <br />CD <br />04 <br />CD <br />) <br />CD <br />cc <br />11-97) <br />CD <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT:5 25 ft <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=4ft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />HIP -35.94 -49.57 -49.57 -49.57 <br />10 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: 7/s' EXP. 1 (2%6) or 15/2' EXP. 1 (3�6) <br />TILE: 1%2' EXP. 1 (3�6) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1%32', SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 0SRS-03 10d (2'/s" x 0.131") NAILS OR ASTM F1667 RSRS 04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(B) <br />(A) <br />I OR 2 PLY <br />'ARRIER <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH (+) <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />VA <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS wO (A) <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE S-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />(2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />OR <br />E AS <br />M Li <br />CONT LEDGER <br />0. <br />0 <br />Cca <br />0 0 <br />0 <br />? <br />IL M <br />U) <br />V) <br />2 <br />Mj <br />Q <br />CCD <br />ao <br />CD <br />04 <br />CD <br />) <br />CD <br />cc <br />11-97) <br />CD <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT:5 25 ft <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=4ft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />HIP -35.94 -49.57 -49.57 -49.57 <br />10 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: 7/s' EXP. 1 (2%6) or 15/2' EXP. 1 (3�6) <br />TILE: 1%2' EXP. 1 (3�6) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1%32', SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 0SRS-03 10d (2'/s" x 0.131") NAILS OR ASTM F1667 RSRS 04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />v <br />�3 <br />ci ,° W <br />�/jr�r <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />Q <br />