My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39108 5th Ave
Zephyrhills
>
Building Department
>
Building Plans
>
39108 5th Ave
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:53:14 AM
Creation date
2/19/2025 8:03:37 AM
Metadata
Fields
Template:
Building Plans
Street #
39108
Location
5th Ave
Contractor
Bay Area Property Aquisition
Building Plans - Permit #
22694
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r- - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />I I <br />I I <br />I I <br />I I <br />I I <br />r---------------� I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J- - - - - - - - - - - - - - - - J- - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />-------------------------------------------------------------- r-------------------- <br />r -I <br />co ' I I <br />'II <br />0� III <br />II II ,�\ III <br />LEGEND I I II <br />I I <br />r---� EXISTING WALL OR ITEM �{/ I I I I <br />I L---J I <br />I I <br />EXISTING WALL OR ITEM OJ` I I I I <br />TO BE REMOVED I I <br />I ' Ie 1 I I <br />I I N II <br />I I p II <br />I <br />I I I I I I <br />I � 1LL I <br />I-------- ----------- ------- � L-J I I I <br />_____-----T--L-----J--i II <br />----- ----- ----------- ----- <br />I I II <br />I I II <br />I I II <br />I I II <br />I I II <br />In --------- II <br />°,w=.w; IiEIFLOOR PLAN <br />qii� e' EXISTINCs <br />r- - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />I I <br />I I <br />I I <br />I I <br />I I <br />r---------------� I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />r- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J- - - - - - - - - - - - - - - - J- - - - - - - - T - - - - - - - - - - - - - - - - - - - - - <br />--------------------------------------------------------------� r-------------------- <br />I f I II <br />I I I I � III <br />I II <br />I I I I CO III <br />1<1 <br />I I I I <br />LEGEND I i IIII <br />I I DOOR SIZE FEET (HGT. 6'-8" I I <br />I UNLESS NOTED OTHERWISE) I I <br />I DOOR SIZE INCHES I I \� III <br />I I I II <br />4EF)IRE-HUNG <br />(PH) or WRAP (W) I I� III <br />I or POCKET (PKT) <br />' L - --- <br />WINDOW SIZE I01 <br />I 34 SH I I <br />CoI I oo, <br />I I <br />I I ® FRAME WALL - <br />I `t <br />I <br />cv <br />I <br />co I Dan \ 3 I 10 -8 X 12 -8„ = <br />�+ I 8'-0" CLG. HGT. v <br />I I I uD <br />I I I I � <br />I I I I <br />NEW WALL / EXISTING <br />I I WALL CONNECTION 11 <br />- - - - - - - - - - - - - - - - - - - - - - - - - - T - - L - - - - - - - <br />----- ----- ---- ----- <br />I 24 SH 24 SN I <br />In <br />L-- - - - - - - C =1 -------------------- <br />J <br />0 <br />�;' IIPIFLOOR PLAN <br />e� PROP03ED <br />NEW WALL / EXISTING <br />WALL CONNECTION <br />A <br />M <br />11 NEW LIVING (1st. STY.): 143 SF <br />DOOR SCHEDULE, <br />OUT <br />SWING DOORS <br />DOOR <br />DISCRPTION <br />FRAME <br />ROUGH OPENING <br />BLOCK <br />ROUGH <br />2868 <br />34" <br />x <br />80 7/8" <br />37" <br />x <br />82 <br />3/8" <br />3068 <br />38" <br />x <br />80 7/8" <br />41" <br />x <br />82 <br />3/8" <br />3068 <br />w/ <br />SINGLE 1068 <br />LIGHT <br />51 1/2" <br />x 80 7/8" <br />54 <br />1/2" <br />x <br />82 3/8" <br />3068 <br />w/ <br />DOUBLE 1068 <br />LIGHT <br />65" <br />x <br />80 7/8" <br />68" <br />x <br />82 <br />3/8" <br />6068 <br />75" <br />x <br />80 7/8" <br />78" <br />x <br />82 <br />3/8" <br />2880 <br />34" <br />x <br />96 7/8" <br />37" <br />x <br />98 <br />1/2" <br />3080 <br />38" <br />x <br />96 7/8" <br />41" <br />x <br />98 <br />1/2" <br />3080 <br />w/ <br />SINGLE 1080 <br />LIGHT <br />51 1/2" <br />x 96 7/8" <br />54 <br />1/2" <br />x <br />98 1/2" <br />3080 <br />w/ <br />DOUBLE 1080 <br />LIGHTS <br />65" <br />x <br />96 7/8" <br />68" <br />x <br />98 <br />1/2" <br />6080 <br />75" <br />x <br />96 7/8" <br />78" <br />x <br />98 <br />1/2" <br />6080 <br />w/ <br />DOUBLE 1080 <br />LIGHTS <br />102 <br />1/4" <br />x 96 7/8" <br />105 <br />1/4" <br />x <br />98 1/2" <br />6080 <br />w/ <br />DOUBLE 3080 <br />LIGHTS <br />150 <br />1/4" <br />x 96 7/8" <br />153 <br />1/4" <br />x <br />98 1/2" <br />6080 <br />w/ <br />DOUBLE 2880 <br />LIGHTS <br />142 <br />1/4" <br />x 96 7/8" <br />145 <br />1/4" <br />x <br />98 1/2" <br />6080 <br />w/ <br />DOUBLE 1280 <br />LIGHTS <br />69" <br />x <br />96 7/8" <br />72" <br />x <br />98 <br />1/2" <br />*NOTE: THE ABOVE DOOR CHART FITS MOST DOOR MANUFACTURERS DOORS <br />HOWEVER THE CONTRACTOR SHALL VERIFY WITH CHARTS / DOCUMENTATION <br />PROVIDED WITH SPECIFIC DOOR MANUFACTURER <br />LEGEND <br />DOOR SIZE FEET (HGT. 6'-8" <br />UNLESS NOTED OTHERWISE) <br />DOOR SIZE INCHES <br />PRE -HUNG (PH) or WRAP (W) <br />or POCKET (PKT) <br />wlNDow s1zE <br />34 SH <br />® FRAME WALL <br />WINDOW ROUGH <br />OPENING CHART <br />WINDOW <br />CODE <br />BLOCK CONSTRUCTION <br />(1/2" FLANGE) <br />FRAME CONSTRUCTION <br />(1/2" FLANGE) <br />WIDTH HEIGHT <br />WIDTH HEIGHT <br />12 SH <br />19 7/8"" <br />x <br />26" <br />19 1/4- x <br />26 1 /4" <br />13 SH <br />19 7/8"" <br />x <br />38 3/8" <br />19 1/4" x <br />38 5 8" <br />14 SH <br />19 7/8"" <br />x <br />50 5/8" <br />19 1/4" x <br />50 7/8" <br />15 SH <br />19 7/8" " <br />x <br />63" <br />19 1/4- x <br />63 1 /4" <br />16 SH <br />19 7/8"" <br />x <br />76 3 4" <br />19 1/4- x <br />76 3 4" <br />H32 SH <br />27 1/4" <br />x <br />26" <br />26 5/8" x <br />26 1/4" <br />H33 SH <br />27 1/4" <br />x <br />38 1/4" <br />26 5/8" x <br />38 5/8" <br />H34 SH <br />27 1/4" <br />x <br />50 5 8" <br />26 5/8" x <br />50 7 8" <br />H35 SH <br />27 1/4" <br />x <br />63" <br />26 5/8" x <br />63 1/4' <br />H36 SH <br />27 1/4" <br />x <br />76 3 4" <br />26 5/8" x <br />76 3 4" <br />22 SH <br />37 3 4" <br />x <br />26" <br />37 1 8" x <br />26 1 4" <br />23 SH <br />37 3 4" <br />x <br />38 1/4" <br />37 1 8" x <br />38 5/8" <br />24 SH <br />37 3 4" <br />x <br />50 5/8" <br />37 1 8" x <br />50 7/8" <br />2WE SH <br />37 3 4" <br />x <br />56" <br />37 1 8" x <br />56 1/4" <br />25 SH <br />37 3 4" <br />x <br />63" <br />37 1 8" x <br />63 1/4" <br />26 SH <br />37 3 4" <br />x <br />76 3 4" <br />37 1 8" x <br />76 3 4" <br />32 SH <br />53 7/8" <br />x <br />26' <br />53 1/4 x <br />26 1/4" <br />33 SH <br />53 7/8" <br />x <br />38 1/4" <br />53 1/4" x <br />38 5/8- <br />34 SH <br />53 7/8" <br />x <br />50 5/8" <br />53 1/4- x <br />50 7/8" <br />3WE SH <br />53 7/8" <br />x <br />56" <br />53 1/4" x <br />56 1/4" <br />35 SH <br />53 7/8" <br />x <br />63" <br />53 1/4" x <br />63 1/4" <br />36 SH <br />53 7/8" <br />x <br />76 3 4" <br />53 1/4" x <br />76 3 4" <br />(2) 22 SH' s <br />74 3 4" <br />x <br />26" <br />CHECK WITH MANUF. <br />(2) 32 SH' s <br />107" <br />x <br />26" <br />CHECK WITH MANUF. <br />(2) 23 SH' s <br />74 3 4" <br />x <br />38 1/4" <br />CHECK WITH MANUF. <br />(2) 33 SH' s <br />107" <br />x <br />38 1/4- <br />CHECK WITH MANUF. <br />(2) 24 SH's <br />74 3 4" <br />x <br />50 5/8" <br />CHECK WITH MANUF. <br />(2) 34 SH's <br />107" <br />x <br />50 5/8" <br />CHECK WITH MANUF. <br />(2) 25 SH* s, <br />74 3 4" <br />x <br />63" <br />CHECK WITH MANUF. <br />(2) 35 SH' s <br />1 107" <br />x <br />63" <br />CHECK WITH MANUF. <br />*NOTE: THE ABOVE WINDOW CHART FITS MOST WINDOW MANUFACTURERS <br />WINDOWS HOWEVER THE CONTRACTOR SHALL VERIFY WITH CHARTS / <br />DOCUMENTATION PROVIDED WITH SPECIFIC WINDOW MANUFACTURER <br />If FRAMING NOTES: II <br />ALL INTERIOR DIMENSIONS ARE GIVEN TO THE INDICATED <br />CENTER OF THE STUD UNLESS NOTED OTHERWISE. <br />ALL EXTERIOR DIMENSIONS ARE GIVEN TO THE FACE OF THE <br />STUD OR FACE OF BLOCK (AS APPROPRIATE) WHICH LINES <br />WITH THE FOUNDATION BELOW. <br />ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE <br />PRESSURE TREATED OR APPROVED CEDAR, OR HAVE 15 LB. <br />FELT BARRIER. <br />SEE SHEETS - S1, S2 AND ADDITIONAL "S" SHEETS <br />FOR ADDITIONAL STRUCTURAL DETAILS / NOTES <br />R602.1 GENERAL. WOOD AND WOOD -BASED PRODUCTS USED <br />FORLOAD-SUPPORTING PURPOSES SHALL CONFORM TO THE <br />APPLICABLE PRO -VISIONS OF THIS SECTION. <br />R602. 1. 1 SAWN LUMBER. SAWN LUMBER SHALL BE <br />IDENTIFIEDBY A GRADE MARK OF AN ACCREDITED LUMBER <br />GRADING ORINSPECTION AGENCY AND HAVE DESIGN VALUES <br />CERTIFIED BY ANACCREDITATION BODY THAT COMPLIES WITH <br />DOC PS 20. IN LIEUOF A GRADE MARK, A CERTIFICATION OF <br />INSPECTION ISSUED BY ALUMBER GRADING OR INSPECTION <br />AGENCY MEETING THE REQUIRE-MENTS OF THIS SECTION SHALL <br />BE ACCEPTED. <br />R602. 1.2 END -JOINTED LUMBER. APPROVED <br />END-JOINTEDLUMBER IDENTIFIED BY A GRADE MARK <br />CONFORMING TO SECTONR602.1 SHALL BE PERMITTED TO BE <br />USED INTERCHANGEABLY WITHSOLID-SAWN MEMBERS OF THE <br />SAME SPECIES AND GRADE. END -JOINTED LUMBER USED IN AN <br />ASSEMBLY REQUIRED ELSEWHERE INTHIS CODE TO HAVE A <br />FIRE -RESISTANCE RATING SHALL HAVE THE <br />DES-IGNATION WHEAT RESISTANT <br />ADHESIVE" OR "HRA" INCLUDED INITS GRADE MARK. <br />R602. 1.3 STRUCTURAL GLUED -LAMINATED TIMBERS. <br />GLUED -LAMINATED TIMBERS SHALL BE MANUFACTURED AND <br />IDENTIFIED ASREQUIRED IN ANSI/AITC A190.1 AND ASTM <br />D3737. <br />R602.1.4 STRUCTURAL LOG MEMBERS. STRUCTURAL LOG <br />MEM-BERS SHALL COMPLY WITH THE PROVISIONS OF ICC 400. <br />R602. 1. 5 STRUCTURAL COMPOSITE LUMBER. <br />STRUCTURALCAPACITIES FOR STRUCTURAL COMPOSITE LUMBER <br />SHALL BE ESTAB-LISTED AND MONITORED IN ACCORDANCE WITH <br />ASTM D5456. <br />R602.1.6 CROSS -LAMINATED TIMBER. CROSS -LAMINATED <br />TIM-BER SHALL BE MANUFACTURED AND IDENTIFIED AS <br />REQUIRED BYANSI/APA PRG 320. <br />R602.1.7 ENGINEERED WOOD RIM BOARD. ENGINEERED WOODRIM <br />BOARDS SHALL CONFORM TO ANSI/APA PRR 410 OR SHALLBE <br />EVALUATED IN ACCORDANCE WITH ASTM 07672. <br />STRUCTURALCAPACITIES SHALL BE IN ACCORDANCE WITH <br />EITHER ANSI/APAPRR 410 OR ESTABLISHED IN ACCORDANCE <br />WITH ASTM D7672.RIM BOARDS CONFORMING TO ANSI/APA PRR <br />410 SHALL BEMARKED IN ACCORDANCE WTH THAT STANDARD. <br />R602. 1 GENERAL. WOOD AND WOOD -BASED PRODUCTS USED <br />FORLOAD-SUPPORTING PURPOSES SHALL CONFORM TO THE <br />APPLICABLE PRO -VISIONS OF THIS SECTION. <br />R602. 1.8 WOOD STRUCTURAL PANELS. WOOD STRUCTURAL <br />PANELSHEATHING SHALL CONFORM TO DOC PS 1, DOC PS 2 OR, <br />WHENMANUFACTURED IN CANADA. CSA 0437 OR CSA 0325. <br />PANELSSHALL BE IDENTIFIED FOR GRADE, BOND <br />CLASSIFICATION, AND PER-FORMANCE CATEGORY BY A GRADE <br />MARK OR CERTIFICATE OFINSPECTION ISSUED BY AN APPROVED <br />AGENCY. <br />R602.1.9 PARTICLEBOARD. PARTICLEBOARD SHALL CONFORM <br />TOANSI A208.1. PARTICLEBOARD SHALL BE IDENTIFIED BY <br />THEGRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY <br />ANAPPROVED AGENCY. <br />R602.1.10 FIBERBOARD. FIBERBOARD SHALL CONFORM TOASTM <br />C208. FIBERBOARD SHEATHING, WHERE USED STRUCTUR-ALLY, <br />SHALL BE IDENTIFIED BY AN APPROVED AGENCY AS <br />CON -FORMING TO ASTM C208. <br />R602.2 GRADE. STUDS SHALL BE A MINIMUM NO. 3, STANDARD <br />ORSTUD GRADE LUMBER. <br />EXCEPTION: BEARING STUDS NOT SUPPORTING FLOORS AND <br />NON -BEARING STUDS SHALL BE PERMITTED TO BE UTILITY <br />GRADE LUMBER,PROVIDED THE STUDS ARE SPACED IN <br />ACCORDANCE WITH TABLER602.3(5). <br />R602.3 DESIGN AND CONSTRUCTION. EXTERIOR WALLS OF <br />WOOD -FRAME CONSTRUCTION SHALL BE DESIGNED AND <br />CONSTRUCTED INACCORDANCE WITH THE PROVISIONS OF THIS <br />CHAPTER AND FIGURESR602. 3( 1) AND R602.3(2). OR IN <br />ACCORDANCE WITH AWC NDS.COMPONENTS OF EXTERIOR WALLS <br />SHALL BE FASTENED IN ACCORDANCEWITH TABLES R602.3(1) <br />THROUGH R602.3(4). WALL SHEATHINGSHALL BE FASTENED <br />DIRECTLY TO FRAMING MEMBERS AND, WHEREPLACED ON THE <br />EXTERIOR SIDE OF AN EXTERIOR WALL, SHALL BE CAPA-BLE <br />OF RESISTING THE WIND PRESSURES LISTED IN TABLE <br />R301.2(2)ADJUSTED FOR HEIGHT AND EXPOSURE USING TABLE <br />R301.2(3) ANDSHALL CONFORM TO THE REQUIREMENTS OF <br />TABLE R602.3(3). WALLSHEATHING USED ONLY FOR EXTERIOR <br />WALL COVERING PURPOSES SHALLCOMPLY WITH SECTION R703. <br />STUDS SHALL BE CONTINUOUS FROM SUPPORT AT THE SOLE <br />PLATE TO ASUPPORT AT THE TOP PLATE TO RESIST LOADS <br />PERPENDICULAR TO THEWALL. THE SUPPORT SHALL BE A <br />FOUNDATION OR FLOOR, CEILING ORROOF DIAPHRAGM OR SHALL <br />BE DESIGNED IN ACCORDANCE WITHACCEPTED ENGINEERING <br />PRACTICE. <br />EXCEPTION: JACK STUDS, TRIMMER STUDS AND CRIPPLE STUDS <br />ATOPENINGS IN WALLS THAT COMPLY WITH TABLES R602.7(1) <br />ANDR602. 7(2) . <br />,t <br />t1 <br />0 <br />L_ <br />C� <br />C <br />N <br />N <br />C <br />0 <br />(n <br />L_ <br />N <br />C <br />L <br />0 <br />U <br />O <br />cV <br />O <br />04 <br />G <br />F- <br />d <br />O <br />U <br />.0 <br />s <br />e <br />
The URL can be used to link to this page
Your browser does not support the video tag.