(3) 3/0 x 3" LAGx's <br />SIMPSON SP2 a EA. STUI <br />I II II <br />se, I I <br />2 x P.T. <br />STUD <br />II II <br />II II <br />II II <br />II II <br />II II <br />SIMPSON 51=1 g EA. STUD I I I I <br />" ANCHOR BOLT 6 32" MIN. <br />(MIN. 8" EMBEDMENT)- <br />ti y <br />o -- • <br />FRAM <br />(3) EVENLY SPACED VERT. <br />TAPCON CONCRETE SCREWS. A <br />MINIMUM OF I" AND A MAXIMUM <br />OF 1-3/4" EMBEDMENT. <br />SIMI-SON SP2 0 EA. STUD <br />SIMPSON SPI a EA. STUD <br />" ANCHOR BOLT m 32" MIN. <br />(MIN. 8" EMBEDMENT) <br />2x P.T. <br />STUD <br />FRAMI <br />- - - <br />- <br />- - - - <br />- - - <br />- <br />��-----T--L-�---U <br />Ii-r <br />-�---1 <br />--r-4- <br />L <br />-i----L <br />i--� <br />--r <br />� <br />0 <br />----� <br />--r--I---�--L <br />-----L--I--1--r <br />TO EX. BLOCK DETAI <br />HARDWARE OPTION ' ' HARDWARE OPTION <br />TABLE R301. 5 <br />MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS <br />(in pounds per square foot) <br />USE <br />LIVE LOAD <br />Uninhabitable attics without storage b,g <br />10 <br />Uninhabitable attics with limited storage b,g <br />20 <br />Habitable attics and attics served with fixed stairs <br />30 <br />Balconies (exterior) and decks e <br />40 <br />Fire escapes <br />40 <br />Guardrails and handrails d <br />200h <br />Guardrail in -fill components f <br />50h <br />Passenger vehicle garages a <br />50a <br />Rooms other than sleeping room <br />40 <br />Sleeping rooms <br />30 <br />Stairs <br />40c <br />For SI: 1 pound per square foot = 0.0479 kPa, 1 square inch = 645 mm2, <br />1 pound = 4.45 N. <br />a. Elevated garage floors shall be capable of supporting a 2,000-pound load applied over a 20-square-inch area. <br />b. Uninhabitable attics without storage are those where the maximum clear height between joists and rafters is less than 42 inches, <br />or where there are not two or more adjacent trusses with web configurations capable of accommodating an assumed rectangle 42 inches <br />high by 24 inches in width, or greater, within the plane of the trusses. This live load need not be assumed to act concurrently with <br />any other live load requirements. <br />c. Individual stair treads shall be designed for the uniformly distributed live load or a 300-pound concentrated load acting over an <br />area of 4 square inches, whichever produces the greater stresses. <br />d. A single concentrated load applied in any direction at any point along the top. <br />e. See Section R502.2 for decks attached to exterior walls. <br />f. Guard in -fill components (all those except the handrail), balusters and panel fillers shall be designed to withstand a <br />horizontally applied normal load of 50 pounds on an area equal to 1 square foot. This load need not be assumed to act concurrently <br />with any other live load requirement. <br />g. Uninhabitable attics with limited storage are those where the maximum clear height between joists and rafters is 42 inches or <br />greater, or where there are two or more adjacent trusses with web configurations capable of accommodating an assumed rectangle 42 <br />inches in height by 24 inches in width, or greater, within the plane of the trusses. <br />The live load need only be applied to those portions of the joists or truss bottom chords where all of the following conditions are <br />met: <br />1. The attic area is accessible from an opening not less than 20 inches in width by 30 inches in length that is located where the <br />clear height in the attic is a minimum of 30 inches. <br />2. The slopes of the joists or truss bottom chords are no greater than 2 inches vertical to 12 units horizontal. <br />3. Required insulation depth is less than the joist or truss bottom chord member depth. <br />The remaining portions of the joists or truss bottom chords shall be designed for a uniformly distributed concurrent live load of not <br />less than 10 lb/ft2. <br />h. Glazing used in handrail assemblies and guards shall be designed with a safety factor of 4. The safety factor shall be applied to <br />each of the concentrated loads applied to the top of the rail, and to the load on the in -fill components. These loads shall be <br />determined independent of one another, and loads are assumed not to occur with any other live load. <br />TABLE 2304. 10. 1 <br />FASTENING SCHEDULE <br />DESCRIPTION OF BUILDING ELEMENTS <br />NUMBER AND TYPE OF FASTENER <br />SPACING AND LOCATION <br />Roof <br />3-8d common 2 x 0. 131, ; or <br />3-10d box (3 x 0. 128. ); or <br />1. Blocking between ceiling joists, rafters or trusses to top <br />3-3" x 0.131"naiis; or <br />Each end, toenail <br />plate or other framing below <br />3-3" 14 gage staples, &" crown <br />2-8d common (2j" X 0. 131' ) <br />2-3" x 0.131" nulls <br />Each end, toenail <br />Blocking between rafters or truss not at the wall top plate, <br />2-3' 14 gage staples <br />2-16 d common (3 x 0.162") <br />to rafter or truss <br />3-3" x 0.131" nails <br />End nail <br />3-3" 14 gage staples <br />16d common ( 31" X 0. 162") 0 6" o. c. <br />3"x 0.131" nails 4 6" o.c. <br />Face nail <br />Flat blocking to truss and web filler <br />3" 14 gage staples 0 6"o.c. <br />3-8d common � 2>1" X 0. 131') or <br />3-10d box (3 x 0.128")or <br />Each joist, toenail <br />2. Ceiling joists to top plate <br />3-3" 0.131" nails; or <br />3-3' 14 gage staples. " crown <br />3. Ceiling joist not attached to parallel rafter, <br />3-16d common (2}" X 0.131")or <br />4-I0d box (3" x 0.128")or <br />Each end, toenail <br />laps over partitions (no thrust) <br />4-3"x 0.131' nails; or <br />(see Section 2308.7.3.1, Table 2308.7.3.1) <br />4-3' 14 gage staples, ?g" crown <br />4. Ceiling joist attached to parallel rafter (heel joint) (see <br />Per Table 2308.7.3.1 <br />Face nail <br />Section 2308.7.3.1, Table 2308.7.3.1) Per Table 2308.7.3. 1 <br />3-10d common (3' X 0. 148") ; or <br />4-10d box (3' x 0. 128" ); or <br />5. Collar tie to rafter <br />4-3" 0.131' nails; or <br />Face nail <br />4-3" 14 gage staples, ?g" crown <br />3-10d common (3' X 0. 148") ; or <br />4-10d box ( 3" x 0. 128") ; or <br />6. Rafter or roof truss to top plate <br />4-3" 0.131' nails; or <br />Face nail <br />(See Section 2308.7.5, Table 2308. 7. 5) <br />4-3" 14 gage staples, ?g" crown <br />2-16d common 3 1 2 X 0. 162 ; or <br />3-10d box (3" x 0. 128" ); or <br />3-3" 0. 131" nails; or <br />3-3' 14 gage staples, &" crown; or <br />End nail <br />7. Roof rafters to ridge volley or hip rafters; or roof <br />3-10d common 3 1/2' X 0. 148;or <br />rafter to 2-inch ridge beam <br />3-16d box (3 1/2" x 0.135");or <br />4-10d box (3"x 0128'); or <br />Toenail <br />4-3'x 0.131' nails; or <br />4-3" 14 gage staples, " crown <br />16d common 3 1 2' X 0.162' ; <br />24'o.c. face nail <br />1 d common 3 X 8 ;or <br />8. Stud to stud not at braced wall panels) <br />( P ) <br />3"x 0.131' nails; or <br />16"o.c. face nail <br />3-3' 14 gage staples." crown <br />16d common 3 1/2" X 0.162 <br />16"o.c. face nail <br />9. Stud to stud and abutting studs at intersecting wall <br />16d box 3 1/2- X 0.135" ;or <br />12-o.c. face nail <br />3 x 0.131 nails; or <br />corners (at braced wall panels) <br />3-3" 14 gage staples, " crown <br />12"o.c. face nail <br />10_ Built-up header (2" to 2' header)) <br />16d common 3 1 2' X 0.162' <br />16"o.c. face nail <br />16d box 3 1,421 X 0. 135 • or <br />12 o. c. face nail <br />11. Continuous header to stud 4-8d common (21/2. X 0. 131, ); <br />4-8d common 2 1/2- X 0.131-);or <br />Toenail <br />4-10d box 3" X 0.128" <br />16d common 3 12 X 0. 162 • or <br />16 o. c. face nail <br />common X );or <br />12. Top plate to top plate <br />3"x 0.131" nails; or <br />12"o.c. face nail <br />3" 14 gage staples, &' crown <br />8-16d common (3 1 2 X 0.162");or <br />Each side of end joint, face <br />12-I0d box (3" x 0. 128"); or <br />nail <br />13. Top plate to top plate, at end joints <br />12-3" 0.131' nails; or <br />(minimum 24" lop splice length <br />12-3" 14 gage staples, &" crown <br />each side of and joint) <br />161 common 3 1 " X 0. 162' • or <br />16 o. c. face nail <br />14. Bottom plate to joist, rim joist, band joist or blocking <br />(not at braced wall panels) <br />°x .1 ;or <br />3"x 0.131' nails; or <br />12"o.c. face nail <br />3" 14 gage staples, ?8' crown <br />2-16d common (3 1/2' X 0.162");or <br />15. Bottom plate to joist, rim joist, band joist or blocking <br />3-16d box (3 1/2" x 0.135");or <br />at braced wall panels <br />4-3' 0.131" nails; or <br />Toenail <br />4-3" 14 gage staples, �' crown <br />4-8d common (2 1/2 X 0.131");or <br />4-10d box (3" x 0.128");or <br />Toenail <br />4-3" 0.131" nails; or <br />4-3" 14 gage stoples,?g" crown <br />16. Stud to top or bottom plate <br />2-16d common (3 1/2" X 0.162 );or <br />3-10d box (3' x 0.128");or <br />3-3" 0. 131' nails; or <br />End moil <br />3-3" 14 gage staples," crown <br />2-16d common (3 1 2 X 0.162 );or <br />3-10d box (3" x 0.128");or <br />17. Top or bottom plate to stud <br />3-3" 0.131" nails; or <br />End moil <br />3-3" 14 gage staples, ?a' crown <br />2-18d common (3 1/2" X 0. 162 ); or <br />3-I0d box (3" x );or <br />18. Top plates, laps at corners and Intersections <br />or r <br />3-3' 0.131* nails; o <br />Face nail <br />3-3' 14 gage staples, ?e" crown <br />2-8d common (2 1/2" X 0. 131"); or <br />2-10d box (3" x 0. 128' ): or <br />19. 1' brace to each stud and plot <br />2-3" 0.131" nails; or <br />Face nail <br />3-3" 14 gage staples, ?g" crown <br />2-8d common (2 1/2" X 0. 131"); or <br />20. 1'x6" sheathing to each bearing <br />3-10d box (3" x 0.128");or <br />Face nail <br />3-8d common (2 1/2" X 0. 131"): or <br />21. 1'x8' and wider sheathing to each bearing <br />3-I0d box (3" x 0.128");or <br />Face nail <br />Floor <br />3-8d common (2 1/2" X 0. 131"); or <br />3-10d box( 3' x 0. 128") ; or <br />22. Joist to sill, top plate, or girder <br />3-3" 0. 131" nails; or Toenail <br />3-3" 14 gage staples, ?S" crown <br />8d common 2 1/2" X 0.131');or <br />10d box (3" x 0.128");or <br />23. Rim joist, band joist, or blocking to top plate, sill or <br />3" 0.131" nails; or 6"o.c., toenail <br />other framing below <br />3' 14 gage staples,&' crown <br />2-8d common (2 1/2" X 0. 131'); or <br />24. I"x 6"subfloor or less to each lolst <br />2-10d box (3' x 0.128");or Face nail <br />25. 2" subfloor to loist or airder <br />2-IB1 common 3 1 2" X 0.182 Face nail <br />26. 2" Tanks lank & beam -floor do roof <br />2-16d common 3 1 2 X 0. 162 Each bearing, face nail <br />32' o.c., face nail at top and <br />20d common (4"x 0.192") bottom <br />atoggered on opposite sides) <br />10d common X 0. 1 ; or 24' o. c. , face nai I at top and <br />27. Built-up girders and beams, 2, lumber layers <br />3"x 0.131" nails; or bottom <br />3' 14 gage staples, ?S' crown staggered on opposite sides) <br />2-20d common 4 X 0. 192 ; or <br />3-10d box (3" x 0.128');or Ends and at each splice, face <br />3-3" 0.131" nails; or nail <br />3-3' 14 gage stoples,?g" crown <br />3-16d common 3 1/2* X 0. 162 ; or <br />4-10d box (3" x 0.128");or Each joist or rafter,face nail <br />28. Led <br />Ledger strip supporting <br />g p pporting joists or rafters <br />4-3" 0.131" nails; or <br />4-3' 14 gage staples. &" crown <br />3-16d common (3 1/2' X 0. 162"); or <br />4-10d box (3' x 0.128");or End nail <br />29. Joist to band joist or rim joist <br />4-3" 0.131' nails; or <br />4-3" 14 gage staples, &* crown <br />3-16d common 3 1/2" X 0. 162"); or <br />4-10d box (3" x 0.128");or End nail <br />30. Bridging or blocking to joist, rafter or truss <br />4-3" 0.131' nails; or <br />4-3" 14 gage staples,?g" crown <br />Wood structural panels (WSP), subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to <br />framing a <br />Edges <br />Intermediate <br />(inches) <br />supports <br />(inches) <br />6d common or deformed (2" x 0.113') <br />6 <br />12 <br />subfloor and wall <br />8d box or deformed (2 1/2'x 0.113') <br />6 <br />12 <br />roof <br />211'xO.113' nail (subfloor and wall) <br />6 <br />12 <br />'- <br />31. 3/8 1/2" <br />1j" 16 gage staple, ?g" crown <br />4 <br />8 <br />subfloor and wall <br />21j" x 0.113. nail (roof) <br />4 <br />8 <br />1 3/4"16 gage staple, ?S'crown(roof) <br />3 <br />6 <br />8d common (2 1/2'x 0.131'); or <br />6 <br />12 <br />32. 19/32 ' - 3/4" <br />6d deformed 2"0. 113" <br />2rxO. 113. nail; or <br />6 <br />12 <br />2 16 gage staple, 7 16 crown <br />10d common (3' x 0. 148") ; or <br />6 <br />12 <br />33. 78" - 1 <br />f <br />Other exterior wall sheathing <br />li" galvanized roofing nail <br />(J' head diameter);or <br />34. 1/2 'fiberboard sheathing b <br />1i', 16 gage staple with ?S'or 1" <br />3 <br />6 <br />crown <br />2-20d common 4 X 0. 192 ; or <br />35. 25/32, fiberboard sheathing b <br />" <br />3-10d box (3x 0. 128"); or <br />3 <br />6 <br />3-3" 0.131" nails; or <br />3-3" 14 gage staples, ?g" crown <br />Wood structural panels, combination subfloor underlayment to framing <br />8d common (2 1/2"x 0.131"), or <br />6 <br />12 <br />36. 4*and less <br />6d deformed 2"xO.113" <br />"- <br />8d common (2 1/2"x 0.131"); or <br />6 <br />12 <br />37. 7/8 1' <br />6d deformed 2"xO. 113' <br />38. 1J"- 1 <br />10d common (3"x 0.148")• or <br />6 <br />12 <br />8d deformed 2 1 2"xO.131" <br />Panel siding to framing <br />6d corrosion -resistant siding <br />( li" X 0. 106"); or <br />6d corrosion -resistant casing (2"X <br />6 <br />12 <br />39. 1/2, or less <br />o. 099" ) <br />8d corrosion -resistant siding <br />40. 5/8' <br />(2 3/8' X 0. 128") ; or <br />8d corrosion -resistant casing <br />6 <br />12 <br />(2 1/2"X 0. 113') <br />Interior paneling <br />_ <br />4d common (1 1/2"x 0.080'); or <br />6 <br />12 <br />41 <br />4d finish 1 1 2"x 0,072" <br />42 i' <br />6d casing (2'x 0.099"); or <br />6 <br />12 <br />6d finish Panel supports at 24" <br />For S1: I inch - 25.4 mm <br />a. Nails spaced at 6 inches of Intermediate supports where spans are 48 inches or more. For nailing of wood structural panel and <br />particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing are permitted to be common, box or casing. <br />b. Spacing shall be 6 inches on center on the edges and 12 Inches on center at intermediate supports for nonstructural applications. <br />Panel supports at 16 inches (20 Inches if strength axis in the long direction of the panel, unless otherwise marked). <br />c. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the ceiling joist is <br />fostened to the top plate In accordance with this schedule, the number of toenails In the rafter shall be permitted to be reduced by <br />one nail. <br />O <br />N <br />O <br />N <br />01 <br />