My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39769 Harvest Creek Ln
Zephyrhills
>
Building Department
>
Building Plans
>
39769 Harvest Creek Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:34:47 PM
Creation date
2/19/2025 8:20:53 AM
Metadata
Fields
Template:
Building Plans
Street #
39769
Location
Harvest Creek Ln
Contractor
Lennar Homes
Building Plans - Permit #
1461
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br />ELECTRICAL SPECIFICATION <br />150A/2 <br />L CINDOOR <br />PANEL CENTER <br />NOTES: <br />V „2t t <br />r14 copper to ngnla a aullau <br />ELECTRICAL CONTRACTOR <br />NEMA 1 #12 copper to 20 amp ckts <br />I R <br />MUST VERIFY WITH THE <br />2W AMP/ 10 N10.2 copper to WH <br />W <br />Y70.3 capper to Dryer <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />V <br />FIXTURES SHOWN ARE FOR <br />METER <br />S�OC <br />LOCATION PURPOSES. <br />200amp 0or4l0SERAIu <br />am <br />3" <br />150 amp <br />UNDERGROUND Ormneol <br />POWER CO. FEED <br />Cl,� h <br />41 ere Cu Ground <br />INTERSYSTEM <br />•Y 'i �p <br />Q <br />UT�N\i <br />BONDING p4GROUNDINGWIRE <br />INk n" Vi`2h <br />TERMINATION PER WITH CODE APPROVED <br />v l: <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />lY 1 <br />T <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be Installed In all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle Installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The Width of the sink or range is not to be Included In the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Fff <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />.® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />&4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I'_0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />JE!!:L <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WP H.B. <br />GFI DISC. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />QI ut nCo <br />ELECTRICAL PLAN — ELEV—Al <br />SCALE: Y4'=1'-0" <br />C= , <br />N <br />N <br />1 <br />N <br />0 <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />E <br />ao <br />ti <br />C <br />(8 <br />aN cb <br />a0 <br />i! LL W <br />dl <br />tn�"L <br />M cDu0d. <br />J W a- <br />wu <br />YJa <br />0QYl <br />U. <br />a <br />P <br />w�MN_ <br />ro <br />m0 <br />ILIL aZ� <br />ZNoCl) <br />y <br />W9 <br />Z <br />Daa. <br />D0 <br />z <br />z <br />Z r` <br />J <br />a) <br />z <br />�_ <br />.0 <br />IN <br />o <br />0 <br />c <br />W <br />c <br />Q � <br />cm <br />S <br />r` <br />Cl) <br />Z <br />W <br />J <br />lE E <br />o <br />OLL <br />0 0. <br />ZQ <br />w'' <br />°w a <br />Z <br />N � <br />a� <br />°d� <br />�Z <br />u� <br />tt <br />��., ~ <br />o <br />ZAD <br />�= <br />O <br />3 <br />a <br />8 <br />Z <br />W <br />CIL <br />SEE <br />J <br />CD <br />Nil <br />O <br />Z <br />Lo <br />ui <br />W <br />C9 <br />.> <br />c <br />N <br />f <br />J <br />N <br />Y <br />CN <br />O <br />^�^,, � <br />m <br />U <br />CD <br />W <br />d' <br />r <br />M o <br />0) <br />e <br />= <br />IT C0 <br />T— <br />N <br />N <br />r <br />M <br />,— <br />M <br />CN <br />y <br />o <br />Z <br />c <br />E Q <br />E <br />H <br />a? <br />c <br />a <br />U <br />JOB <br />NO: <br />20-8087 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.