My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5027 9th St (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5027 9th St (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:04:57 AM
Creation date
2/19/2025 8:21:28 AM
Metadata
Fields
Template:
Building Plans
Street #
5027
Location
9th St
Contractor
Kerns Family
Building Plans - Permit #
18524
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Framina Lavout Notes: <br />1 Framing layout drawn by Daniel M. Ossman Drafting Sere, Inc. is a schematic <br />representation only. It is the responsibility of General Contractor to make a field <br />inspection to verify "ALL" existing field conditions including accuracy in dimensions with <br />proposed plans. General Contrar "DUST' certify in waiting (the time and date) that <br />this field inspection was conducted on and submitted to truss manufacture. If this field <br />inspection was "NOT" done prior to giving said plans to the truss manufacture, then the <br />"GENERAL CONTRACTOR WILL BE HELD LIABLE FOR ALL COST OF ANY / ALL <br />MISTAKES" on pre-engineered trusses that are constructed for said project. Daniel M. <br />Ossman Drafting Service, Inc. "VWLL NOT RE HELD LIABLE" for errors made on any <br />framing (floor or roof) truss layouts. <br />2 Upon receiving said plans from the General Contractor ... the truss manufacture <br />"MUST" make a their "OV01" field inspection to "DOUBLE CHECK" all existing field <br />conditions, roof slopes, overhangs, and dimensions prior to the manufacturing of any / all <br />trusses. Truss manufacture "MUST" certify (the time and date) that this field inspection <br />was conducted on by their company. This certification must be given to the General <br />Contractor in writing prior to the manufacturing of any / all trusses on said project. <br />3 All thickened slabs / footing on foundation plan are located according to the schematic <br />truss layout drawn by Daniel M. Ossman Drafting Service, Inc. Only truss manufacture <br />can change these locations due to truss bearing points and "MUST" notify General <br />Contractor of these changes as soon as possible. <br />4 All hurricane truss straps specified on said project are to be used unless otherwise <br />specified by truss manufacture. All hurricane straps specified are "Simpson Strong Tie" <br />( or equal ), unless noted otherwise_ Only truss manufacture can change any / or all <br />truss straps that are specified on truss layout drawn by Daniel M. Ossman Drafting <br />Service, Inc. Truss manufacture must first notify General Contractor in waiting of these <br />changes as soon as possible. <br />5 Truss design drawings shall be prepared in accordance to and conformance with section <br />R802.1.6.1. These documents shall be provided by the truss manufacture at time of truss <br />delivery and approved by the building official prior to the installation of the roof truss. <br />(See code section items 1-13). <br />6 This plan as indicated is diagrammatical in nature for permit and contract purposes only. <br />Any revisions as required by the truss company's engineer as indicated on truss company's <br />sealed drawings shall superseded this drawing. This also includes truss company's <br />specified hurricane and other anchors supersede one shown on this drawing. <br />7 If shingles are being used, shingles MUST comply with section 905.2.2, 905.2.4.1 and <br />table R - 905.2.6.1 for wind resistance, FBC residential code 5th edition (2014) residential. <br />8 CONTRACTOR, MUST COORDINATE WITH TRUSS MANUFACTURE FOR ALL VAULTED, TRAY, <br />FLAT AND OR OTHER CEILING TYPES. CONTRACTOR IS 100% RESPONSIBLE FOR THE <br />EXTERIOR WALL CONSTRUCTION METHOD WHERE A GABLE END IS CONSTRUCTED. <br />ALL EXTERIOR WALLS MUST COMPLY WITH THE FBC RESIDENTIAL CODE 5TH EDITION <br />(2014) RESIDENTIAL, SECTION R - 609 FOR CONSTRUCTION METHODS. SEE ADDITIONAL <br />ATTACHED STRUCTURAL SHEETS FOR GABLE END BRACING DETAILS. DANIEL M. OSSMAN <br />DRAFTING SERVICE AND ARCHITECT WHO SIGNED / SEALED THE PLANS, ASSUMES NO <br />RESPONSIBILITY DUE TO NEGLIGENCE OF THE CONTRACTORS FAILURE TO FOLLOW <br />THE BUILDING CODE FOR GABLE END CONSTRUCTION. <br />Connection Schedule <br />Manufacturer <br />Model No. <br />Uplift <br />FI Product Approval <br />Location / Use <br />Name <br />Number <br />Simpson <br />Strong Tie <br />SP1 <br />#585 <br />FI 10456.11 R3 <br />Bottom plate to wood stud connection. <br />Simpson <br />Strong Tie <br />SP2 <br />#1065 <br />FI 10466.11 R3 <br />Top plate to wood stud connection. <br />Simpson <br />Strong Tie <br />ABU44 <br />#2200 <br />FI 10860.4 R3 <br />4 x 4 bottom post connection to wood post. <br />Simpson <br />Strong Tie <br />BC4 <br />#980 <br />FI 10860 R3 <br />4 x 4 top post connection to wood post. <br />Simpson <br />HUSC210- <br />#3295 <br />FI 10655.25 R3 <br />2 - 2 x 10 wood beam hanger to exterior frame wall <br />Strong Tie <br />2 <br />of house. <br />Simpson <br />H10 <br />#995 <br />FI 10466.3 R3 <br />Roof structure connection to exterior frame wall or <br />Strong Tie <br />wood beam. <br />Simpson <br />MTS20 <br />#1000 <br />FI 10456.8 R3 <br />Alternate - Roof structure connection to exterior <br />Strong Tie <br />frame wall or wood beam. <br />Nole: <br />1. Any products that are substituted, must "MUST" or "EXCEED" products specified. Contractor "MUST" provide <br />data to building inspector at time of inspection. Only truss company can modify hurricane clips and connections <br />specified and must coordinate with General Contractor with any changes to plans. <br />2. It's the responsibility of the truss manufacture to coordinate all cathedral ceiling locations with General <br />Contractor before the manufacturing of any floor and / or roof trusses. All ceiling heights are to be a minimum <br />of 10' - 0" unless otherwise specified by General Contractor. <br />� � 3 <br />a� <br />a � � <br />_ C> <br />6 M O <br />, a <br />' � a <br />v <br />A �c <br />— <br />.r- ai <br />r <br />CL Ca 10 0o <br />� 70 Lo L <br />a0) <br />c=ac�r�o <br />N � v NQ M <br />r su <br />a <br />> �zs <br />CJ? t+j f-0 � e 0 <br />L L 4.i.7 <br />LL <br />4) cu <br />E'WE <br />� U 0 c� <br />0 0 2 N C`) <br />®'S a,<t > <br />L <br />f <br />O E� a <br />i E � s-- ua E <br />L 0 m N to <br />C <br />oO QCU <br />om= aaCO <br />U) wU U) C <br />C -E <br />C,4 fl <br />}� CN <br />vLo <br />as <br />CM <br />VJ <br />ui <br />fr% N <br />z CL <br />-C <br />L0 N <br />0 N <br />JOB NO. <br />5027 9TH STREET <br />DATE <br />FEBRUARY 10, 2017 <br />DRAWN BY <br />Daniel M. Ossman <br />too <br />ff <br />14 <br />Main house roof pitch: 6.5 / 12 <br />Front porch roof pitch: 5 / 12 <br />Main house finish ceiling height: 10' - 0" <br />Front porch finish ceiling height: 8' - 0" <br />All door and window header height to <br />start at: 8' - 0" <br />ROOF FRAMING LAYOUT <br />SCALE: 1/4" - 1' — 0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.