My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5843 17th St
Zephyrhills
>
Building Department
>
Building Plans
>
5843 17th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:24:00 AM
Creation date
2/19/2025 8:22:21 AM
Metadata
Fields
Template:
Building Plans
Street #
5843
Location
17th St
Contractor
Delamora Abraham-Homeowner
Building Plans - Permit #
347
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL, PLUMBING & MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT. "AFI" CIRCUIT. <br />ALL ELECTRICAL OUTLETS IN BEDROOMS & FIXTURES SHALL BE WIRED INTO AN ARC —FAULT INTERRUPTER. <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS. <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARING THE DWELLING FROM THE <br />GARAGE SHELL BE CONSTRUCTED OF MINIMUM NO.26 GAUGE SHEET OR OTHER APPROVED MATERIALS <br />AND SHALL HAVE NO OPENINGS INTO THE GARAGE (FBC 6TH EDITION 2017 R309) <br />FLORIDA STATUTE 471 <br />ONLY REQUIRES ENGINEERING ON RESIDENTIAL IF THE COST OF' THE INDIVIDUAL PLUMBING, ELECTRICAL, <br />OR MECHANICAL IS OVER $125,000 OR IS OVER 250 FIXTURE UNITS PLUMBING, OVER 600 AMPS <br />ELECTRICAL AND 15 TONS OR OVER MECHANICAL. <br />FBC BUILDING CHAPTER 1 (105.3.1.2) <br />SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />6TH EDITION, 2017 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01/08 AND HAVING A <br />FOSSIL- FUEL-BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2017 6TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII - ELECTRICAL) <br />NEC 2017: 210.12 - ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 - INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO <br />BE: 12" AFF (GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES <br />TO BE GANGED, WHERE POSSIBLE <br />3. ELECTRICAL SWITCHES TO BE 42" <br />CENTERLINE AFF. <br />4. ELECTRICAL PLAN IS INTENDED FOR <br />BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR <br />WHO SHALL BE RESPONSIBLE <br />FOR THE INSTALLATION & SIZING OF <br />ALL ELECTRICAL, WIRING & ACCESSORIES. <br />5. GROUND WIRE FORM REBAR TO <br />ELECTRICAL PANEL PER N.E.C. 2017 <br />SYMBOL <br />DESCRIPTION <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />110 V RECEPTICLE(1/2 SWITCHED) <br />110 V RECEPTICLE <br />6GF1 <br />110 V RECEPTICLE - GROUND FAULT <br />6AFI <br />110 V RECEPTICLE - ARC FAULT <br />6 <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />6 <br />220 V RECEPTICLE <br />0 <br />DUPLEX OUTLET IN FLOOR <br />8 <br />110 V QUAD <br />8wp <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />' <br />FLOURESCENT FIXTURE <br />FLOOD LAMPS <br />VANTITY LIGHT <br />cp <br />PUSH BUTTON FOR GARAGE OPENER <br />S&D <br />SMOKE /FIRE DETECTOR/ALARM <br />C&M <br />SMOKE/CARBON MONOXIDE DETECTOR - COMBO <br />© <br />CARBON MONOXIDE DETECTOR <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />FAN <br />= I DISCONNECT <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />MECHANICAL: <br />2" STUDOR VLV <br />WC <br />SHOWER SINK <br />SINK <br />4" C.O. <br />LOCATE AND <br />2" STUDOR VLV <br />CONNECT^TO EXISTING PLUMBING ISOMETRIC <br />CONDENSATE <br />LINES SHALL <br />DISCHARGE <br />AT LEAST 12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND <br />PIPING, TAIL <br />EXTENSIONS, <br />OR SPLASH <br />BLOCKS. <br />2017 FMC, 6TH EDITION - EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT. <br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR. <br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME <br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY. <br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS <br />LOCATED IN THE ATTIC (WHEN APPLICABLE). <br />NOTE: <br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATION CODE, <br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS. <br />PLUMBING NOTES: <br />BATHROOM PLUMBING <br />FIXTURE HEIGHTS: <br />SHOWER HEAD <br />77" <br />ABV. SHOWER F.F. <br />SHOWER VALVE <br />46" <br />ABV. SHOWER F.F <br />TUB/SHOWER HEAD <br />80" <br />A.F.F. <br />TUB/SHOWER VALVE <br />30" <br />A.F.F. <br />TUB/SHOWER SPOUT <br />22" <br />A.F.F. <br />TAP <br />oOUTSIDE WATER TAP <br />.€ 3. <br />PLUMBING PLAN <br />PLUMBING: <br />ALL PLUMBING FIXTURE LOCATIONS ARE TO BE DETERMINED BY THE PLUMBING CONTRACTOR. <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATION CODE, <br />PLUMBING SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS. <br />ALL FIXTURE LOCATIONS MUST BE VERIFIED FROM FLOOR PLAN AND IS THE RESPONSIBILITY OF <br />PLUMBING CONTRACTOR TO PLACE FIXTURES IN CORRECT LOCATION. PLUMBING DRAIN LAYOUT <br />WILL BE DETERMINED IN FIELD BY CONTRACTOR. <br />0 <br />I <br />ELECTRICALIHVAC <br />
The URL can be used to link to this page
Your browser does not support the video tag.