My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6043 Harriet St
Zephyrhills
>
Building Department
>
Building Plans
>
6043 Harriet St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:30:47 AM
Creation date
2/19/2025 8:22:25 AM
Metadata
Fields
Template:
Building Plans
Street #
6043
Location
Harriet St
Contractor
Village Square Builders
Building Plans - Permit #
11539
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATE : <br />I/31/1� <br />SCALE: <br />1/4 11 _ V ^II <br />I <br />�0/ <br />PAGE 1 <br />ENGINEER'S NOTES : <br />ALL WORK IS TO BE IN COMPLIANCE WITH ACCE-1, THE FLORIDA <br />BUILDING CODE 2001 EDITION, AND THE 2009 .SUPPLEMENTS WITH <br />ALL REVISIONS AND UPDATES TO FBC-01, <br />lU THE BASIC DESIGN WIND SPEED = 120 MPH (3 SECOND MUST) <br />2) THE IMPORTANCE FACTOR = LO <br />3) THE EXPOSURE CATEGORY = B <br />4) THE INTERNAL PRESSURE COEFFICIENT = +/- 0.18 (ENCLOSED) <br />5) THE COMPONENT AND CLADDING DESIGN PRESSURES ARE <br />ZONE 1 ( +10.5 -21.5) ZONE 2 (+10,5 -34,1) ZONE 3 ( +14.13 -50.1) <br />FOR A BUILDING WITH A MEAN ROOF HEIGHT OF LESS THAN <br />30'-0" EXPOSURE B. <br />,ASSEMBLY GROUP B LESS THAN 150 SF <br />UBMWMED PLAN(S) NAB <br />2Y ZEPHYRHILLS FIRS A <br />Please be advised this; review of plans submitted is a <br />cursory review to assist the contractor in compliance with <br />applicable fire safety cosies. his review is not int-,nded <br />to be a final approval of the submitted plans. it is the <br />contractor's sole responsibility to ensure that the plans are in <br />complete compli,,nce with all applicable Nrt'A,codes and <br />local ordinances. In the event that further c Vamina+Eon or <br />site inspection reveals areas cf no--compli:..rsce, h small be <br />the contractor's sole responsibility, at their sole expense to <br />bring those areas in compliance. The City assumes no <br />responsibility for the contractor's failure to be in compliance <br />with all applicable NFPA Codes and local ordinances. <br />UNION CORRUGATING EXISTING METAL ROOF <br />5V METAL ROOFING FLO4586.1 <br />11--11_-11--11--11_11--1I_-11--T-11--11--T-11--11--11--11-- IF 11--T-11--11--11--11--11--11--11-- IF -1--1--1--1--11--1--1--1--1--1--1-- IF -1--11--11--11--Tr 1-1r- <br />-� _ [TP5 SH 25 SH 25 SH 25 SH 25 <br />M <br />Li z � o LIJ <br />z <br />RAMP AND SLAB BY OTHERS <br />►n <br />12'-0" <br />LEFT ELEVATION <br />HEM <br />FRONT ELEVATION <br />4'-0 I' 1_ 6'-0" 6'-011 <br />RIGHT ELEVATION <br />EXISTING BUILDING <br />4'-6" 1 2'-10" 1 12'-0° I- 12'-0" 1_ 12'-0" S'-8" <br />o <br />y o <br />II ADDITION t0 DINING AREA <br />�ry� \ <br />O DP 24.1+ / 2Ca,9- 49 <br />'d SH 25 5H 25 5H 25 5H 25 <br />DP 25_g+ / 28_1- DP 25.9+ / 28-1- DP 25.9+ / 28.1- DP 25.9+ / 28.1- <br />4'-6" 1 6'-8° 1_ 9'-4" �, 9'-4" 9'-ro 6'-8�� <br />46'-O" I, 6'-O'I <br />52'-0" <br />MAIN FLOOR PLAN <br />M <br />110 <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-206-5821 <br />OFFICE FAX 352-588-2342 <br />S, HANLEY P 0 BOX 1325 SAN ANTONIO <br />FLA. 33516 <br />EMAIL. Han ley06-membargmaiLaom <br />SEE THE SIMPSON STRONG TIES CATALOG FOR <br />ANY ADDITIONAL INFORMATION ON ANY OF THE <br />SIMPSON FASTENERS SPECIFIED ON THIS PLAN, <br />CATALOG C-2010 EFFECTIVE I/ 1/ 10 <br />BECAUSE THIS IS AN ADDITION IT WILL BE THE RESPONSIBILITY <br />OF ALL SUBS AND SUPPLIERS TO VERIFY ALL INFORMATION IN <br />THE FIELD BEFORE ORDERING ANY MATERIAL OR STARTING <br />ANY WORK. IF ANY INFORMATION IS NOT ON THIS PLAN THE <br />CONTRACTOR WILL NEED TO VERIFY THAT THE NEW WORK IS <br />MATCHING THE EXISTING. <br />DESIGN PRESSURES <br />THE DESIGN WIND PRESSURE RATINGS ARE LISTED <br />FOR EACH OPENING.THE WINDOWS AND DOORS <br />CHOOSEN BY THE HOMEOWNER OR CONTRACTOR <br />WILL NEED TO MEET OR EXCEED THESE PRESSURES <br />LISTED BY EACH OPENING. THIS MANUFACTURERS <br />INFORMATION WILL BE REQUIRED BEFORE ANY <br />INSTALLATION OF THESE PRODUCTS. <br />43 <br />s <br />ALL WORK SHALL COMPLY WITH ALL <br />PREVAILING CODES, FLORIDA BUILDING <br />CODE, NATIONAL ELECTRIC CODE AND <br />CITY OF ZEPHYRHILLS ORDINANCES <br />REVIEW DATE <br />CITY OF ZEPHYRHILLS <br />PLANS EXAMINER <br />12 <br />JOB NAME AND ADDRESS. <br />PINECREST MOBILE }-TOME PARK <br />6043 HARRIET STREET <br />ZEPHYRHILLS, FLA, 33542-3213 <br />EXTENDING DINING ROOM <br />rO06 SF <br />-- <br />VERIFY ALL CONDITIONS AND SF BEFORE <br />BIDDING OR CONSTUCTION <br />DAVID W. SMITH, MS. PE, <br />FLORIDA LIC.* 53608 <br />352-521-0865 OFFICE 352-521-0861 FAX, <br />9909 WALLASTON DRIVE DADE CITY ,FLA. 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />- PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />ASCE-1, THE FLORIDA BUILDING CODE 2001 EDITION <br />AND THE 200c3 SUPPLEMENTS WITH ALL REVISIONS <br />AND UPDATES TO FBC DAVID W. SMITH MS. PE. # 53608 <br />
The URL can be used to link to this page
Your browser does not support the video tag.