Laserfiche WebLink
SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS' <br />1 /411 = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICT'S BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BEAT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />APR 0 8 2023 <br />Virtual Review Assist. II — <br />Plans Review completed and approved <br />for compliance with the 2020 18, 2t' Editian <br />by Rehra Anne Vilahr P1 '3dp <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />T <br />SWITCH Uj <br />° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET c� <br />TRIM--- <br />BASE--- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�}. TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-�— SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-cam 4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--o DIMMER SWITCH AT 36" <br />—0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />-- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />- TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />�} CLG FAN PREWIRE AND SWITCH <br />Cos COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18- UNDER CABINET 18" <br />-S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />c S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />5F24:;g 24" VANITY LIGHTING <br />5Frm 36 :FR 36" VANITY LIGHTING <br />4848" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />Cj EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />® INTERCOM SPEAKER AT S-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />= MASTER STATION <br />_ffiiiQ ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />E3 A/C REGISTER <br />(T� THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED, LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />C'.0 <br />_W L o U <br />� � - <br />.6.C'i } <br />OW u <br />V V rn <br />-0` 2 " <br />A� C s <br />W �_oo ao <br />� O�� °¢ <br />DC ��° <br />,0^` � ■ W �N <br />W L 0O ECO <br />70 0 r\ CL <br />W <br />0 <br />W <br />ow W0 <br />�-< � _j x¢~z� <br />¢ <br />�°�¢o¢�¢��o0-10 <br />z <br />0Y <br />H <br />W � W p <br />�a�w0 0X00m0?¢0 <br />-j- <br />O 0 <br />0O Z <br />`��[L>DWW�_ U-x¢o <br />J¢�¢0W¢F,-Lu W00Q <br />J <br />a. <br />LL <br />H <br />00w x C) � 000¢x¢ <br />W¢ o W <br />O <br />O <br />Z <br />W <br />O�_ <br />O <br />I.-:M <br />Q u� m � <br />(n LL <br />ti <br />z <br />< W o- Lq <br />�I�or) <br />Z U <br />W <br />J O <br />O <br />d' <br />is <br />00 <br />O <br />O <br />O <br />o <br />N <br />m <br />N <br />o <br />N <br />0 <br />N <br />m <br />0 <br />N <br />M <br />0 <br />N <br />0 <br />N <br />d <br />0 <br />O <br />Z <br />0 <br />o <br />r- <br />o <br />0 <br />o <br />I <br />O <br />W <br />Q <br />N <br />LO <br />> <br />o <br />o <br />M <br />0 <br />.4 <br />0 <br />L6 <br />o <br />6 <br />i <br />M' <br />LO <br />z� <br />W <br />Qz <br />w <br />O <br />W <br />coo <br />♦'+ <br />O <br />U U U <br />Lowo <br />C� <br />z <br />=zj <br />a a <br />Lri <br />= <br />Q <br />m=w <br />Et <br />N <br />0 <br />Zo= <br />Q <br />U <br />gW� <br />wLL <br />Z <br />az <br />�z <br />Z <br />0 <br />J <br />00 <br />W <br />z <br />Z <br />z <br />� <br />Lu <br />W <br />ti <br />00 <br />LAST PLOT DATE <br />0 <br />• <br />March 23, 2023 <br />O <br />2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />ABKL&M <br />