SIN <br />CONT. HANDRAIL <br />RETURN TO <br />i WALL DETAIL <br />SCALE: NTS <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/411 <br />(16) RISERS AT 7 -9/16" <br />10" TREADS w/ 3/4" NOSING <br />42" KNEE WALL WITH <br />1x8 CAP & CASING - <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 <br />36" H. CONT. 15 <br />/' / <br />GRASPABLE 14_ <br />RAILING 13 <br />' 12 <br />I , <br />I ' <br />I .10 <br />/ <br />42" KNEE = i ,' 10 <br />WALL WITH �`oo 1 s 1 x TREAD <br />1x8 CAP & (0 I �;��o (TYP.) <br />CASING I - STORAGE <br />7 UNDER <br />A i 6 STAIRS <br />1x8 CAP & ; 5 2x FRAMED <br />CASING 1,4 WALL <br />3 1x RISERS <br />(TYP.) <br />2 (3) 2x12 <br />1 STRINGERS <br />1 11 <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4 x 3 1/2rTAPCONS @ <br />161111o.c. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />SCALE: 1/2" = V-0" <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1, <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM 0 <br />LANDING FRAMING <br />(2) 2x HDR. <br />REQ'D @ EN[ <br />LANDING FOF <br />STRINGERS - <br />CONNECT TC <br />2x FRAMED <br />WALL <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'4" MAX LANDING LENGTH <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />3/4" PLYWOOD EXTERIOR WALLS --\ <br />DECKING <br />FLOOR SYSTEM <br />,K7 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />J <br />S6 <br />TYP. <br />U.N.O. <br />H1 <br />(1)D2 <br />6 <br />QJ, <br />I nn U, I i� <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />251SI <br />*EGRESS <br />OWNER'S <br />SUITE <br />8'-0" FLAT CLG. <br />CARPET <br />G.T. - <br />T <br />BEDROOM 4 <br />V-0" FLAT CLG. <br />CARPET <br />1/2 WALL OR - <br />RAILING PER SP <br />d„ 1 2668 <br />2668 <br />BF - <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />* WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.* <br />THIS /S ONLY USED IMTH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />** WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS- <br />--------------------I <br />26-0" I I <br />I I <br />I I <br />CH1 I <br />61 I I <br />A D I <br />I <br />25 SH 1 I <br />* EGRES „ <br />I I I <br />I I <br />Cal 4 516 7 8 19 10 11 <br />i------ <br />R&S 2652 <br />------ -- R/A H <br />4068 N <br />d <br />BF <br />5'-10" 5'-01, G �' <br />G.T. <br />60 X 36 TB <br />_ <br />SHOWER to <br />FIBERGLASS cn <br />SURROUND <br />-- <br />TP <br />i 5'-0" <br />4' ' - <br />2 8 . BATH <br />8'- " FLAT CLG <br />co <br />2068 <br />TILEI <br />BF <br />- <br />4-SH <br />R&S <br />WIC <br />I <br />2068 - - 8'-0" FLAT CL . <br />r4" 61-P ' CARPET I cA <br />1.�,�►' AC,�ESS � ab <br />R&S <br />o <br />BA -2 <br />8-0"-FLAT CLG. <br />NIII E TB <br />TECH CENTER <br />N <br />In' Y 5068 BF <br />a 5 s LAUD W. ' <br />0 8'-0" FLAT CLG. <br />is TILE <br />" 3'-10" 3' 11" <br />D. I <br />BEDROOM 3 <br />8'-0" FLAT CLG. <br />CARPET <br />*EGRESS <br />2 SH 25 SH I <br />O <br />1 9 © 39 22 (A)qD2D1 D1;r, JAMB STUD OVER IOil <br />I <br />ENTRY TO BE I I <br />CONNECTED DOWN I I <br />PER DETAIL 6/D2 I I <br />L-----------------------------------JI <br />16'-8" 5'-10" <br />I <br />I 5068 - <br />1 V-2" - - 2' <br />' I <br />tn u) I <br />BEDROOM 2 =I <br />8'-0" FLAT CLG. <br />CARPET <br />I <br />1 <br />* <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 91 /4" <br />LVL 2.0E Fb=2950 <br />e <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />1 TYP. @ <br />)2 CORNERS <br />�� <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />co <br />T <br />TUB/ SHWR <br />TILE TO 7' <br />A.F.F. <br />IN <br />6 (12 <br />� <br />- HANSON BOX <br />@ 36" A.F.F. <br />J <br />A <br />-DRYER VENT <br />THRU SIDE <br />WALL <br />-WIRE SHELF <br />@ +54" A.F.F. a <br />TYP. <br />U.N.O. <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />�A <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />+28.3 / -30.8 <br />,D <br />+28.3 / -37.0 <br />E <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GCS <br />SEE SN SHEET �H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED, THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X28 <br />18JX25J <br />S.H. <br />13 <br />20 X 38 J <br />18 J X 371 <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20X63 <br />18JX62i <br />S.H. <br />16 <br />20X72 <br />18�X71 J <br />S.H. <br />1 H2 <br />27 114 X 26 <br />26 X 25 J <br />S.H. <br />1H3 <br />271/4X38Jg <br />26x371 <br />S.H. <br />1 H4 <br />271 X 501 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 IX 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 X 26 <br />36 J X 25 112 <br />S.H. <br />23 <br />37 J X 38 i <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 501 <br />36 � X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 1 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 J X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 J <br />S.H. <br />33 <br />54 X 38 J <br />52 } X 37 <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 1 X 71 I <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly Into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Ed. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bid. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />I I I I I I <br />I I MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING <br />WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA <br />TABULATION <br />FIRST LIVING <br />728 S.F. <br />SECOND LIVING <br />1036 S.F. <br />TOTAL LIVING <br />1764 S.F. <br />LANAI <br />60 S. F. <br />GARAGE <br />379 S.F. <br />ENTRY <br />62 S.F. <br />TOTAL SQ. FT. <br />2265 S.F. <br />INSULATION REQ. <br />EXT FRAME 2 x 4 <br />R-11 /R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />SECOND FLOOR PLAN -A <br />SCALE: Y4"=1'-0" <br />e� <br />c%A <br />43 <br />> 43 <br />o � <br />Q <br />R1 /0 M C� M <br />C !> [ V <br />- <br />w: c�a <br />• N coo <br />2 <br />�AY;v <br />E c <br />y <br />V • _ 'd <br />� 3 � <br />=d� <br />= .W-- U ea <br />O m = <br />c <br />co ,� <br />M <br />0 <br />N <br />ti <br />0 <br />ItiO i�,i�/f <br />s <br />I.J0 <br />• <br />.rlj <br />OF <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />rF,�// <br />Q EE 2 <br />p0 N 8 S3 <br />N � Ol qM <br />O <br />di <br />.'' G 0�0 LL <br />�M@ v LL °: a <br />LL a �; <br />6 <br />z <br />=ag o� <br />W <br />3Ng d <br />?' °' z <br />LL <br />W <br />co C7 6 y F <br />t <br />o ❑❑❑ <br />W <br />N <br />Z' <br />z F�- <br />U_ <br />�+_J <br />jt` <br />f13 <br />w g <br />V <br />0 <br />Z8 <br />V) <br />N <br />ro <br />C N <br />� <br />c <br />_io <br />Cn <br />a� <br />a E <br />E U <br />o0 <br />z <br />a® <br />a <br />H too <br />�'oa <br />00 <br />ZE <br />"=wz <br />g <br />a� <br />i c <br />' <br />Q O <br />�y <br />V <br />w <br />m 0 <br />g� <br />Z <br />J <br />V <br />Q W <br />Zz <br />ab <br />Go <br />JU <br />az <br />W <br />O <br />r� <br />w <br />o� <br />s_ <br />p <br />2.a <br />�_ <br />o O <br />12Lo <br />Oc <br />TM <br />S <br />Liz <br />co Lo <br />:3N <br />C <br />Ln <br />.-. <br />Q <br />J <br />N <br />101' <br />O <br />Lid <br />CY) <br />U M <br />O <br />tca <br />z1 o <br />Ln <br />�- <br />Q <br />f- <br />T <br />E <br />c ^ <br />Lai <br />LO <br />M <br />Z <br />E N <br />N <br />c <br />E <br />y <br />c <br />aJ <br />IL <br />0 _J¢ <br />o <br />JOB <br />NO: <br />23-03654 <br />SCALE: <br />AS NOTED <br />SHEET NO. <br />1.2 <br />