ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the Installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />�3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />>< <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />��9 <br />o J <br />ROUGH -IN FOR OPT. CEILING FAN <br />Q��Z? <br />.� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L 7 J <br />OPT. CEILING FAN <br />(9D <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />n <br />200 amp <br />150 amp <br />UNDERGROUND DI <br />SERVICE BY POWER CO.---. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />#14 to lights & outlets <br />012 to appliances and GFI <br />#10 to WH <br />#8 to Range <br />#6 to HVAC <br />150=210 <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />AC PAD <br />DISC. WP <br />GFI <br />A <br />r ■ <br />I� 'I <br />11 ALT 11 <br />11 AC PAD <br />DINING � <br />OPWPT. 5'-0" r, / <br />LIGHT AS PER <br />■ SPECS <br />PENDANT <br />LIGHT PER <br />SPECS <br />GREAT RM <br />0ROUGH-IN � � <br />FOR OPT. U.C. OUTLET <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: Y4'=1'-0" <br />�-----Li�NAA1----� <br />I `�\ / > I <br />� V <br />I Gff <br />I / Ak <br />— <br />ORKF'ST.i- <br />LIGHT ASPER <br />SPECS <br />i <br />5'r03" <br />4 <br />,I <br />G'FI <br />�I <br />- - <br />I <br />f�k <br />I <br />G <br />` <br />I - <br />I IF <br />_ <br />IGFI <br />1 <br />1III�I ��IIII <br />1 I III <br />, 'a1 <br />- <br />7ni <br />FAN/LIGHT 4/ I <br />SWITCH FOR( FIII I� <br />OPT. CLG. FAN/ I DISPOSAL 1 I <br />LIGHT PRE -WIRE — — <br />1 <br />111 <br />m 111 <br />MMNNNNMN� <br />moll <br />C�ER GFI @44" \ �Y `- <br />A.F.F. 1 UWH. <br />i ZW <br />z <br />0 <br />rIL— <br />■ a <br />Ie GARAGE CC <br />CC <br />DB GFI `LIGHT AS <br />PER SPECS // w <br />> LU <br />GARAGE,./ <br />&GARAGE <br />ENTRY 1 DoGFI <br />R <br />I I - <br />IIr----— — — — — — — — — — — — — — — — — — — — — — — — — - -- <br />I <br />I I I I I <br />IRRIGATION GFI <br />@44"A.F.F. <br />■ I ' I ■ <br />I � I <br />I I -- <br />I / I <br />- <br />_ <br />-,L----------_C09n-CfGAT�---------- <br />OR PREWIRE AS <br />\ \ PER SPECS <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />------- <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />f — I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A.F.F. <br />—Ill 3" VTR 1.5" VTR <br />I� III <br />I I, <br />I I <br />I I <br />I I <br />Imo' <br />�lll 3" VTR <br />I � I <br />I I r�/ I I <br />I I <br />PLUMBING RISER. <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN -A <br />SCALE: Y4"=1'-0" <br />N <br />0 <br />hl <br />0Y r O <br />c eo C.� cM•,e <br />N ��a <br />C" N G <br />Todm� <br />G ra <br />c � <br />a <br />M <br />N <br />CS <br />N <br />LO <br />�+ o <br />�D <br />r <br />n <br />T TE <br />F , <br />rjilIgal{to <br />To the hest of the Engineers knowledge, information end belies, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residentlal 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />a <br />of ^' N <br />O C""8 <br />V <br />O <br />N O C <br />LL <br />Lro- <br />04 0u. d li <br />ICcoo <br />V <br />M U_ a �t <br />Z <br />�. <br />a (2 m J <br />a Z <br />Z <br />LL_ <br />U) �a oW <br />N f7 Z � � H <br />Z <br />Z <br />O U ❑[]❑ <br />W <br />z <br />U) <br />Q <br />a <br />N <br />Ln <br />- <br />GA <br />�LL <br />LU <br />0 <br />LQ <br />u) <br />in <br />YZ-0- <br />as <br />z <br />C) <br />Q <br />C <br />ss <br />o <br />Bch <br />� <br />oU <br />pQ <br />Z <br />oa <br />@ <br />w 6 <br />4 <br />a- <br />� <br />m <br />C <br />v¢ <br />W <br />C§ <br />�O <br />�C <br />r <br />-2 <br />O3 <br />°O <br />= <br />� U <br />120 <br />m <br />O <br />CO <br />CN <br />� N <br />o <br />Lr) <br />CN <br />< <br />Cr <br />a' <br />w m <br />_' <br />04 <br />N <br />'F'0 <br />O <br />CM <br />cr) <br />04 <br />LO <br />t— <br />Q <br />W N <br />LO <br />r <br />L <br />C O <br />z <br />z <br />E N <br />C <br />a <br />ci 0 <br />w <br />¢ o <br />°�' <br />JOB <br />NO: <br />23-03654 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />