Laserfiche WebLink
r IIi�I��IWI,I I I ul" Its <br />0(2)— <br />TYP. @ HIP <br />CORNERS <br />1 <br />I <br />------------------I <br />I � <br />I � <br />I � <br />I II <br />j U UUj <br />U G�r— <br />TYP. U U <br />I U.N.O. I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />VIND SPEED (ULTIMATE) 140.0 MPH <br />VIND SPEED (ALLOWABLE) 108.4 MPH <br />:XPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />AREA ROOF 1 2e 2n 2r 3 3e 3r a=oft <br />10 HIP -35.94 -49.57 49.57 -49.57 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 -78,58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: 3/6" EXP. 1 CY16) or %2' EXP. 1 (3�116) <br />TILE: 1%2" EXP. 103,116) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1%2", SHEATHING SHALL BE FASTENED <br />WITH ASTM Fi667 0SRS-03 10d (2Yz" x 0.131") NAILS OR ASTM F1667 RSRS-AA (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. <br />p <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 -10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />IFGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />-- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5l8" ANCH. / (26) 1 0dx1-1 /2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26)10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 21/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 "* <br />8 -10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8-10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 -16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-112" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SOS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY 11 <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />I <br />1 <br />1EPDXY <br />V <br />(2)LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F`/ <br />) <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 161 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-10d x 1 1/2" <br />SP1 <br />555 <br />535 <br />10 -10d <br />SPT22 <br />735 <br />8 - 10d <br />SP2 1 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 <br />590 <br />555 <br />12-10d x 1 1/2" <br />HHCP2 <br />680 <br />570 <br />20 10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />'** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS - ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (6) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ('*). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. Rt <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS I 11 N0 O <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 6-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />(2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />x CONT CEDGER-J - A) <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ROOF FRAMING PLAN - ELEV - A <br />SCALE: Y4"=1'-0" <br />_ <br />jL2_ c'M <br />0 <br />U_ <br />-14r Q_ <br />N O L_ <br />�- O M <br />.�, a) <br />.�. C <br />E Q <br />Q O <br />U U � <br />i ..� •— (Q <br />w (D QQ <br />— E <br />0 <br />!A 0 O <br />�_ CB >✓ 70 <br />> > 0 ,W <br />Irk- , <br />0 IV <br />•C �'` nr0 +; CV <br />A\ c- <br />_. .,< FjO <br />- rY F: L 40 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages beadng <br />Engineer's signature and seal. <br />Q <br />Co <br />O fat <br />O N J <br />04 <br />C <br />"ao� �[*``w <br />O ,�a <br />S v J Lu <br />�MC� U. n• SX� <br />LL LL L S <br />z 0 <br />Z r m 0 o <br />o 0 <br />o <br />J J <br />-j '„rp N G go <br />W °2 <br />rn�Oi Q0-a <br />= N �2Ci a <br />OLL aarg0 <br />U U N <br />Z <br />W ❑ ❑ ❑ <br />TOWNS <br />Z <br />Z W <br />z <br />o <br />v <br />a <br />N CD 5 <br />U <br />0 LAJ s <br />IN Ly N <br />U) <br />/v{(I <br />LU t0 <br />U <br />• <br />Q <br />o <br />� <br />8O <br />sg <br />Q <br />E U <br />~ <br />W� <br />o <br />oa: <br />D� <br />Z <br />— <br />E <br />N <br />a 0 <br />o <br />0 % <br />d �g <br />ao <br />�� <br />ry <br />C <br />- C <br />z <br />A 8 <br />N <br />0 <br />Z FF <br />Cn J <br />�p <br />8° <br />Q W <br />gw <br />OV <br />"$ <br />gI <br />° <br />QO <br />= <br />�Yl Y 1 <br />O <br />4 <br />m <br />0 <br />M <br />t'0 .d. <br />O <br />r <br />C <br />T <br />U) m <br />N <br />O <br />N <br />LO <br />T <br />Q •.. <br />T <br />T' <br />ai <br />M <br />(`V <br />�'"� y N <br />o <br />z <br />z <br />E O <br />E .. 10 w <br />a <br />U � Q p <br />JOB <br />NO: 22-02353 <br />SCALE : AS NOTED <br />SHEET NO. <br />6.2 <br />