Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />10 014 copper to lights & outlets <br />NEMA 1 012 copper to 20 amp ckts <br />150 AMPI <br />200 AMP 10 010.2 Copper to WH <br />01 910-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />INTERSYSTEM <br />A <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER ;WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Ara Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.WEATHERPROOF DUPLEX OUTLET <br />P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />6. <br />j4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1 WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO EXHAUST FAN <br />;Q11 EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />�BP PUSH BUTTON SWITCH (OPTIONAL) <br />Cp PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />C� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />w�' <br />>-OQ <br />EE <br />>_m <br />WP <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS — <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN. <br />SCALE: %4'=1'-0" <br />----LANAI---- ■ <br />I � I. /40 I <br />I I <br />I I AC PAD <br />GFI GFI DISC. <br />I � <br />■ ■ dimoff <br />f <br />Iqp <br />---- <br />I <br />- -- -1 iBRKIFtt. DINING - <br />-IGMT AI PR <br />3o <br />�SPEICS I! 5'-0„ <br />— <br />■ 5'-" - \ <br />-- - LIGHT AS PER <br />I ! <br />SPECS <br />I <br />PENDANT <br />GF LIGHT PER <br />SPECS <br />GREAT RM ii _ <br />GFII .-1- - I O GFIII _ _ - <br />I <br />■ t I I ROUGH -IN <br />U.C. OUTLET FOR OPT. <br />`? ( ZI _ I I (/ FAN/LIGHT <br />I- �1 1 1 <br />Ell <br />F I SWITCH D SPOSALOR N <br />I1 L GHT PRE-W RE <br />i._ <br />t-- - I <br />II <br />1 <br />1-1017 <br />" I <br />I I 1 <br />■ -- - 4 - CH 6 fr_:� <br />—-7-4T L S I 1 I I 1I S I 1 H - <br />- -- I I I I I <br />1 14 1 I I I I II I I I I 4 I <br />■ L—IL — —t---_ -- <br />/ ' 'V GFI @ 44" <br />UW.H. <br />A.F.F. <br />I <br />- <br />■ J <br />I 1 <br />O Z <br />�a I <br />/ <br />GARAGE <br />U LIGHT AS <br />w PER SPECS <br />-- <br />>w \ / <br />\GARAGE <br />- <br />_ <br />GARAGE / <br />DOOR <br />- <br />If <br />- <br />-GFI <br />- r----------------------- ----� <br />I I I <br />IRRIGATION GFI I I <br />■ I @ 44" A.F.F. <br />1 <br />-- <br />I 1 <br />I � I <br />I <br />I <br />I � I <br />I � I <br />i------------------------------ ■� <br />----------------------------- <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />LIAIV GFI <br />6 <br />ENTRY <br />-----------------7 <br />I I <br />I I <br />I I <br />I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I 1 <br />r� _�-I <br />If IrI <br />11 ALT 11 VP� <br />11 AC PAD I I l V A <br />WP <br />-OPT. <br />�i <br />�------ WIC <br />___ <br />I <br />RECEPT. FOR �`1_- <br />ALARM SYSTEM <br />I <br />--------� �---' <br />MASTER <br />BEDROOM <br />/ OPT. CLG. FAN/ <br />I / LIGHT PRE -WIRE <br />HANSON <br />BOX <br />n <br />VTR 3" VTR Ill_ <br />III, �I <br />�I I <br />I I <br />I I <br />I 1 <br />I r� <br />3" VTR ill- <br />I � I <br />I nu <br />- S.D. � WC V 3" <br />1 - -- 3" <br />/OPT. CLG. FAN/ <br />moo <br />LIGHT PRE -WIRE <br />— f — -- <br />B1 T2 � <br />PROVIDE PHONE / CABLE <br />ANDOUTLETATTECH BEDROOM 4 <br />CENTER / S.D. <br />----� M PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />3 4 ti I I BE VERIFIED WITH PLUMBER <br />T <br />OS I H <br />B LW <br />__--W-- ---U -JII flin <br />I T '-N <br />\�GFI @--------- <br />I <br />44" A.F.F. H A\f� <br />1 <br />IJ <br />S.D. <br />I \\ <br />OPT. CLG. FAN I <br />LIGHT PRE -WIRE / <br />BEDROOM 3 <br />% I <br />✓ I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />A <br />BEDROOM 2 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />ELECTRICAL PLAN - ELEV-A_ <br />> <br />co <br />N <br />•r o- X <br />Z ' M 0 M <br />c�WY <br />(;� C D <br />v <br />fA <br />E�_Q <br />CZ <br />Q O <br />N > � U W <br />C: <br />03 0 <br />> <br />W N Q-0 <br />wL_LIzEc <br />Co O 0 <br />: C 0 <br />> > o W <br />C'V <br />O <br />21 <br />N <br />CV <br />C:� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />fa S <br />�r <br />O CS <br />N CS J u- <br />0 @ LL W <br />tC) <br />�rNnv� U. Clx <br />�LLLL a 0 <br />0 <br />-p <br />Z = to o <br />O'�Ncp m0� <br />W <br />a <br />= N M Z J N 0 <br />_ <br />ILj <br />Z d V Cn <br />W ❑ ❑ ❑ <br />0 M V <br />Z N co <br />z OD <br />z <br />- N <br />ON <br />N <br />v <br />Ocg <br />U <br />® tL J <br />U <br />0 <br />M <br />Ll <br />g E <br />os <br />F <br />=-a <br />E 0 <br />< <br />°& <br />0- <br />9s <br />Z- <br />m <br />¢�S <br />a <br />WSJ <br />Z <br />to <br />CY <br />4Z <br />'O <br />o <br />2LL <br />N <br />a� <br />W <br />S <br />N <br />W <br />�O <br />� <br />oo <br />.2O <br />� <br />> Ln <br />a; <br />m <br />N <br />0 <br />M <br />�C) <br />C Y <br />m <br />N <br />T <br />O <br />N <br />In <br />Q r- <br />T <br />ui <br />z <br />Al N <br />' co N <br />c <br />? <br />E O <br />0 <br />a <br />-1 a <br />JOB <br />NO: 22-02353 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />r• MAN10 <br />� <br />00 � <br />I <br />