3- 2/0 THNN CU FEEDERS
<br />2' GALV RISER
<br />2' CHASE W/0) #210 THW COP.
<br />OR <3) #410 THW AL.
<br />200 AMP MAIN BREAKER
<br />200 AMP 40 CIRCUIT SURFACE MOUNT
<br />METER SOCKET PANEL ON INSIDE GARAGE WALL
<br />0 0
<br />�I 2' GALV NIPPLE
<br />UNDERGROUND SERVICE I�
<br />RODS 2-EACH 8'-0' APART MIN,
<br />CIF AVAILABLE? — I #4 CU DRIVEN .GROUND
<br />.
<br />J
<br />3/8' X 8' GROUND ROD
<br />CONCRETE ENCASED 'UFER' ELECTTODE REQUIRED PER ART 250-50
<br />N,E,C, MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT,
<br />NOTE, ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE
<br />PROVISIONS OF THE NFPA 70 - 08, LOCAL CODES AND THE LOCAL POWER CO.
<br />TYPICAL ELECTRICAL RISER DIAGRAM
<br />o
<br />AFI
<br />may'"
<br />AFI
<br />RAFI
<br />GFI
<br />9AFI
<br />3
<br />AFI
<br />1
<br />CE
<br />AFI 3
<br />FAN W%L
<br />FAN W `` AFL- -'1
<br />�\
<br />AFI
<br />NOTES:
<br />UNLESS ❑THERWISE NOTED
<br />1, ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR
<br />CENTERED LINE OF THE BOX TO BEi 12' AFF (GENERAL)
<br />KITCHEN 44' AFF
<br />BATHROOM 39' AFF
<br />LAUNDRY ROOM 36' AFF
<br />EXTERI❑R WATERPROOF 12' AFF
<br />GARAGE GENERAL PURPOSE 42' AFF
<br />RANGE 2' AFF
<br />2, ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE P❑SSIBLE
<br />3, ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF,
<br />4, ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL
<br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST
<br />EDITI❑N, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESP❑NSIBLE
<br />FOR THE INSTALLATI❑N & SIZING OF ALL ELECTRICAL, WIRING & ACCESS❑RIES,
<br />5, ALL SMOKE DETECTORS SHALL BE HARDWIRED INT❑ AN ELECTRICAL POWER SOURCE
<br />AND SHALL BE EQUIPPED WITH A M❑NIT❑RED BATTERY BACKUP,
<br />INSTALL SMOKE DETECTOR/CARBON M❑N❑XIDE ALARMS PER FBC R313;
<br />6, ALL CIRCUITS ARE REQUIRED TO BE EITHER ARC FAULT OR GROUND FAULT
<br />PROTECTED PER NEC 2011 210A2 (B)
<br />7, ALL RECEPTACLES ARE TO BE CHILD PROTECTED PER NEC 2011 406.11
<br />8, GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E,C, 2011
<br />9, R313,2 1 CARBON M❑N❑XIDE PR❑TECTI❑N, CARBON M❑N❑XIDE ALAMRS OR DETECTORS
<br />SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA70, SUC
<br />DEVICES SHALL BE LISTED BY THE APPR❑PRIATE STANDARD, EITHER ANSI/UL 2034,
<br />STANDARD FOR SINGLE AND MULTIPLE STATI❑N CO ALARMS ❑R UL 2075, GAS
<br />AND VAPR❑ DETECTOR SENSOR, ACC❑RDING TO THE INSTALLATI❑N,
<br />10 , 3132,2 3 C❑MBINATI❑N ALARMS, C❑MBINATI❑N SMOKE/CARBON M❑N❑XIDE ALARMS
<br />SHALL BE PERMITTED IF EACH MEETS THE APPLICATI❑N UL STANDARD,
<br />11, KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS,
<br />12, IN NEW C❑NSTRUCTI❑N, SMOKE DETECTORS SHALL BE HARDWIRED INTO THE A/C
<br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A M❑NIT❑RED BATTERY
<br />BACKUP.
<br />13, BATHROOM EXHAUST FANS MUST VENT TO THE EXTERI❑R OF THE BUILDING,
<br />VENTILATI❑N TO ATTIC SPACE AND S❑FFITS IS NOT ACCEPTABLE,
<br />14, ALL DOORS AND WIND❑WS PR❑VIDING DIRECT ACCESS FROM THE HOME TO THE
<br />POOL SHALL BE EQUIPPED WITH A EXIT ALARM C❑MPLYING WITH UL 2017 THAT
<br />HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER
<br />HARDWIRED OR OF THE PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A
<br />C❑NTINU❑US AUDIBLE WARNING WHEN THE DOOR OR WIND❑W ARE OPENED.
<br />15, ADD GFCI PR❑TECTI❑N TO RECEPTABLES IN LAUNDRY ROOMS AND UTILITY ROOMS
<br />OF DWELLINGS WHERE INSTALLED WITHIN 6' IF THE ❑UTSIDE EDGE OF A SINK,
<br />THIS WOULD INCLUDE THE RECPETACLE INSTALLED FOR A WASHING MACHINE,
<br />RECEPTABLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A
<br />RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24',
<br />THE WIDTH OF A SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF ALL
<br />OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THAN 12'
<br />FOR STRAIGHT COUNTER TOPS AND 18' FOR SINKS AND RANGES INSTALLED IN
<br />C❑RNER C❑LINTERS,
<br />SYMBOL
<br />DESCRIPTION
<br />SWITCH
<br />$3
<br />3 WAY SWITCH
<br />$4
<br />4 WAY SWITCH
<br />$R
<br />RHEOSTAT SWITCH
<br />8
<br />110 V RECEPTICLE(1/2 SWITCHED)
<br />8
<br />110 V RECEPTICLE
<br />8GFI
<br />110 V RECEPTICLE - GROUND FAULT
<br />8AFI
<br />110 V RECEPTICLE - ARC FAULT
<br />8WP
<br />110 V RECEPTICLE - WATERPROOF OUTLET
<br />220 V RECEPTICLE
<br />DUPLEX OUTLET IN FLOOR
<br />110 V QUAD
<br />IBWP
<br />110 V QUAD WATERPROOF OUTLET
<br />RECESSED INCANDESCENT
<br />`?
<br />LIGHT FIXTURE - WALL OR CEILING (TYP)
<br />EXHAUST BATH FAN 110 V 50 CFM'S
<br />EXHAUST FAN/LIGHT C❑MBINATI❑N
<br />®
<br />FL❑URESCENT FIXTURE
<br />�b
<br />FLOOD LAMPS
<br />VANTITY LIGHT
<br />GD
<br />PUSH BUTTON FOR GARAGE OPENER
<br />S@D
<br />SMOKE /FIRE DETECTOR/ALARM
<br />C@M
<br />SMOKE/CARBON M❑N❑XIDE DETECTOR - COMBO
<br />©
<br />CARBON M❑N❑XIDE DETECTOR
<br />In
<br />'
<br />CEILING FAN ONLY
<br />n
<br />CEILING FAN /LIGHT
<br />`\
<br />FAN WIA
<br />ELECTRICAL METER
<br />ELECTRICAL PANEL
<br />ELECTRICAL PLA1\1