Laserfiche WebLink
3- 2/0 THNN CU FEEDERS <br />2' GALV RISER <br />2' CHASE W/0) #210 THW COP. <br />OR <3) #410 THW AL. <br />200 AMP MAIN BREAKER <br />200 AMP 40 CIRCUIT SURFACE MOUNT <br />METER SOCKET PANEL ON INSIDE GARAGE WALL <br />0 0 <br />�I 2' GALV NIPPLE <br />UNDERGROUND SERVICE I� <br />RODS 2-EACH 8'-0' APART MIN, <br />CIF AVAILABLE? — I #4 CU DRIVEN .GROUND <br />. <br />J <br />3/8' X 8' GROUND ROD <br />CONCRETE ENCASED 'UFER' ELECTTODE REQUIRED PER ART 250-50 <br />N,E,C, MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT, <br />NOTE, ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 08, LOCAL CODES AND THE LOCAL POWER CO. <br />TYPICAL ELECTRICAL RISER DIAGRAM <br />o <br />AFI <br />may'" <br />AFI <br />RAFI <br />GFI <br />9AFI <br />3 <br />AFI <br />1 <br />CE <br />AFI 3 <br />FAN W%L <br />FAN W `` AFL- -'1 <br />�\ <br />AFI <br />NOTES: <br />UNLESS ❑THERWISE NOTED <br />1, ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BEi 12' AFF (GENERAL) <br />KITCHEN 44' AFF <br />BATHROOM 39' AFF <br />LAUNDRY ROOM 36' AFF <br />EXTERI❑R WATERPROOF 12' AFF <br />GARAGE GENERAL PURPOSE 42' AFF <br />RANGE 2' AFF <br />2, ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE P❑SSIBLE <br />3, ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF, <br />4, ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST <br />EDITI❑N, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESP❑NSIBLE <br />FOR THE INSTALLATI❑N & SIZING OF ALL ELECTRICAL, WIRING & ACCESS❑RIES, <br />5, ALL SMOKE DETECTORS SHALL BE HARDWIRED INT❑ AN ELECTRICAL POWER SOURCE <br />AND SHALL BE EQUIPPED WITH A M❑NIT❑RED BATTERY BACKUP, <br />INSTALL SMOKE DETECTOR/CARBON M❑N❑XIDE ALARMS PER FBC R313; <br />6, ALL CIRCUITS ARE REQUIRED TO BE EITHER ARC FAULT OR GROUND FAULT <br />PROTECTED PER NEC 2011 210A2 (B) <br />7, ALL RECEPTACLES ARE TO BE CHILD PROTECTED PER NEC 2011 406.11 <br />8, GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N,E,C, 2011 <br />9, R313,2 1 CARBON M❑N❑XIDE PR❑TECTI❑N, CARBON M❑N❑XIDE ALAMRS OR DETECTORS <br />SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA70, SUC <br />DEVICES SHALL BE LISTED BY THE APPR❑PRIATE STANDARD, EITHER ANSI/UL 2034, <br />STANDARD FOR SINGLE AND MULTIPLE STATI❑N CO ALARMS ❑R UL 2075, GAS <br />AND VAPR❑ DETECTOR SENSOR, ACC❑RDING TO THE INSTALLATI❑N, <br />10 , 3132,2 3 C❑MBINATI❑N ALARMS, C❑MBINATI❑N SMOKE/CARBON M❑N❑XIDE ALARMS <br />SHALL BE PERMITTED IF EACH MEETS THE APPLICATI❑N UL STANDARD, <br />11, KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS, <br />12, IN NEW C❑NSTRUCTI❑N, SMOKE DETECTORS SHALL BE HARDWIRED INTO THE A/C <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A M❑NIT❑RED BATTERY <br />BACKUP. <br />13, BATHROOM EXHAUST FANS MUST VENT TO THE EXTERI❑R OF THE BUILDING, <br />VENTILATI❑N TO ATTIC SPACE AND S❑FFITS IS NOT ACCEPTABLE, <br />14, ALL DOORS AND WIND❑WS PR❑VIDING DIRECT ACCESS FROM THE HOME TO THE <br />POOL SHALL BE EQUIPPED WITH A EXIT ALARM C❑MPLYING WITH UL 2017 THAT <br />HAS A MINIMUM SOUND PRESSURE RATING OF 85 DBA AT 10 FEET, AND EITHER <br />HARDWIRED OR OF THE PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A <br />C❑NTINU❑US AUDIBLE WARNING WHEN THE DOOR OR WIND❑W ARE OPENED. <br />15, ADD GFCI PR❑TECTI❑N TO RECEPTABLES IN LAUNDRY ROOMS AND UTILITY ROOMS <br />OF DWELLINGS WHERE INSTALLED WITHIN 6' IF THE ❑UTSIDE EDGE OF A SINK, <br />THIS WOULD INCLUDE THE RECPETACLE INSTALLED FOR A WASHING MACHINE, <br />RECEPTABLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A <br />RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24', <br />THE WIDTH OF A SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF ALL <br />OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THAN 12' <br />FOR STRAIGHT COUNTER TOPS AND 18' FOR SINKS AND RANGES INSTALLED IN <br />C❑RNER C❑LINTERS, <br />SYMBOL <br />DESCRIPTION <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />8 <br />110 V RECEPTICLE(1/2 SWITCHED) <br />8 <br />110 V RECEPTICLE <br />8GFI <br />110 V RECEPTICLE - GROUND FAULT <br />8AFI <br />110 V RECEPTICLE - ARC FAULT <br />8WP <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />220 V RECEPTICLE <br />DUPLEX OUTLET IN FLOOR <br />110 V QUAD <br />IBWP <br />110 V QUAD WATERPROOF OUTLET <br />RECESSED INCANDESCENT <br />`? <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT C❑MBINATI❑N <br />® <br />FL❑URESCENT FIXTURE <br />�b <br />FLOOD LAMPS <br />VANTITY LIGHT <br />GD <br />PUSH BUTTON FOR GARAGE OPENER <br />S@D <br />SMOKE /FIRE DETECTOR/ALARM <br />C@M <br />SMOKE/CARBON M❑N❑XIDE DETECTOR - COMBO <br />© <br />CARBON M❑N❑XIDE DETECTOR <br />In <br />' <br />CEILING FAN ONLY <br />n <br />CEILING FAN /LIGHT <br />`\ <br />FAN WIA <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />ELECTRICAL PLA1\1 <br />