My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6437 Ashville Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6437 Ashville Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:28:22 PM
Creation date
2/19/2025 8:26:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6437
Location
Ashville Dr
Contractor
Ryman Construction
Building Plans - Permit #
17305
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE No, 2 <br />REINF❑RCING SCHEDULE & LOAD CAPACITIES <br />SAFE W❑RKING LOADS (PLF) <br />8' x 8" LINTELS <br />MARK <br />NO. <br />LINTEL <br />LENGTH <br />CLEAR <br />SPAN <br />LINTEL <br />TYPE <br />LINTEL <br />TOP <br />BARS <br />LINTEL <br />BOTTOM <br />BARS <br />GRAVITY SAFE LOAD <br />UPLIFT SAFE LOAD <br />SAFE LATERAL LOADS (PLF) <br />PLAIN <br />S❑LID <br />#5(1)U(0)L <br />S❑LID <br />#5(1)U(1)L <br />S❑LID <br />#5(1)U(o)L <br />#5(1)U(1)L - <br />S❑LID <br />#5(2)U(I)L <br />8"x8" <br />(PLAIN) <br />8"x8' <br />(S❑LID) <br />A BAR <br />B BAR <br />DETAIL A <br />DETAIL B <br />DETAIL C <br />DETAIL B & C <br />DETAIL D <br />M-1 <br />2'-10' <br />1'-6" <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />4245 <br />7809 <br />7809 <br />8529 <br />10000 <br />1998 <br />3964 <br />M-2 <br />3'-6' <br />2'-2' <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />2475 <br />3837 <br />3837 <br />4815 <br />4815 <br />1168 <br />2318 <br />M-4 <br />4'-6" <br />3'-2' <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />1343 <br />2165 <br />2165 <br />2608 <br />2608 <br />638 <br />1266 <br />M-7 <br />5'-10' <br />4'-6' <br />Precast <br />(2) #3 <br />(2) #3 <br />NONE <br />860 <br />1423 <br />1423 <br />1470 <br />1609 <br />543 <br />1105 <br />TABLE No. 9 <br />REINF❑RCING SCHEDULE & LOAD CAPACITIES <br />SAFE W❑RKING LOADS (PLF) <br />8" x 8" RECESS DOOR HEADER <br />MARK <br />NO, <br />TOTAL <br />LENGTH <br />CLEAR <br />SPAN <br />LINTEL <br />TYPE <br />TOP <br />BAR <br />LINTEL <br />BOTTOM BAR <br />GRAVITY SAFE LOAD <br />UPLIFT SAFE LOAD <br />LATERAL SAFE LOAD <br />PLAIN <br />S❑LID <br />#5(1)U(0)L <br />S❑LID <br />#5(1)U(1)L <br />S❑LID <br />#5(1)U(0)L <br />#5(1)U(1)L <br />S❑LID <br />#5(2)U(1)L <br />PLAIN <br />S❑LID <br />A BAR <br />B BAR <br />DETAIL DA <br />DETAIL DB <br />DETAIL DC <br />DETAIL DB & DC <br />DETAIL DF <br />DETAIL DA <br />DETAILDB <br />D-1 <br />3'-8' <br />2'-4" <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />1360 <br />1691 <br />1691 <br />2234 <br />2234 <br />1172 <br />2071 <br />D-2 <br />4'-0' <br />2'-8' <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />1131 <br />1425 <br />1425 <br />1863 <br />1863 <br />950 <br />1677 <br />D-4 <br />4'-4' <br />3'-0" <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />963 <br />1230 <br />1230 <br />1596 <br />1596 <br />785 <br />1386 <br />2' RECESS <br />DETAIL 'DB' <br />ENGINEERING SPECIFICATI❑NS: <br />1.) SAFE LOADS ARE TOTAL SUPERIMPOSED ALLOWABLE LOADS. <br />2.) DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY <br />CALCULATING MAX, RESISTING SHEAR AND MOMENT FOR THE LISTED LINTELS. <br />3.) SAFE LOADS LISTED ON ALL TABLES ARE IN UNITS OF POUND PER LINEAR FOOT, <br />GENERALNOTE <br />1.) CODES <br />1,1 FLORIDA BUILDING CODE 5TH EDITI❑N 2014 <br />1.2 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02). <br />13 AMERICAN S❑CIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER <br />STRUCTURES (ASCE 7-10). <br />2.) CONCRETE: <br />2.1 CONCRETE C❑MPRESSIVE STRENGTH AT 28 DAYS <br />211 PRE —CAST W/STANDARD REINF❑RCEMENT-4000 PSI MIN. <br />212 PRE -CAST W/PRESTRESS REINFORCEMENT-6000 PSI MIN. <br />2.1.3. GROUT PER ASTM C476 — 3000 PSI W/ MAX, 3/8' AGGERATE, 8' TO 11' SLUMP, <br />2.2 REINF❑RCING BARS, <br />2.2.1 STEEL PLACED IN PRECAST LINTEL AT TIME OF <br />FABRICATION ASTM A615 (GRADE 60) <br />2.2.2 STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) ASTM A615 (GRADE 40). <br />23 PRESTRESS STRANDS ASTM A416 7—WIRE, STRESS RELIEVED 270 KSI <br />2.4 DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315, <br />2,5 CONCRETING ❑PERATIONS SHALL COMPLY WITH ACI STANDARDS. <br />3J MAS❑NRY+ <br />3.1 DESIGN AND CONSTRUCTI❑N SHALL CONFORM TO THE SPECIFICATI❑N OF THE NATI❑NAL <br />CONCRETE MASONRY ASSOCIATI❑N AND ACI 530-02. <br />3.2 MINIMUM MASONRY UNIT STRENGTH+ F'M 1500 PSI. <br />3.3 MORTAR SHALL BE TYPE S. <br />4J STRUCTURAL <br />41 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8' (WITH A MINIMUM <br />ACCEPTABLE BEARING OF 4' PER SECTI❑N 2101.3.1 OF FLORIDA BUILDING CODE 2007 (INCLUDING <br />2009 SUPPLEMENTS) <br />42 FOR LINTELS THAT ARE GREATER THAN 14'-0' CLEAR SPAN THEY SHALL BE PROVIDED A <br />TEMPORARY SUPPORT AND THE TEMPORARY SUPPORT SHALL NOT BE REMOVED UNTIL 2 DAYS <br />AFTER GROUT PLACEMENT, <br />D-4 M-4 <br />2668 SH25 <br />DETAIL 'DB' DETAIL 'B' <br />M-4 D-4 <br />SH 13 2468 <br />DETAIL 'B' DETAIL 'DR' <br />M-1 <br />18x36 <br />DETAIL 'B' <br />M-4 M-4 <br />SH35/2 M-4 D-4 M-4 SH35/2 <br />DETAIL 'B' SH25 3068 SH25 DETAIL 'B' <br />DETAIL 'B' DETAIL 'DB' DETAIL 'B' <br />❑ ❑ ❑ ❑ <br />LINTEL <br />PLAN <br />I hereby certif y that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 5th Edition 2014 <br />David W, Smith, P.E. #53608 <br />
The URL can be used to link to this page
Your browser does not support the video tag.