My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6445 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6445 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:44:34 PM
Creation date
2/19/2025 8:26:28 AM
Metadata
Fields
Template:
Building Plans
Street #
6445
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE: <br />SEE SHEET S-11,12 '1873' <br />FOR LINTEL CALLOUTS & <br />DETAILS <br />30'-0" <br />9'-10" 15'-6" <br />LINE OF ROOF <br />ABOVE <br />9 <br />A7 <br />CONC. PAD <br />- <br />°° <br />SH 35 <br />3 1/2" <br />0 1'-0" <br />N <br />HB HD AT T-4" <br />1 5068 SGD <br />I <br />1 <br />I <br />I FAMILY ROOM DINING ROOM <br />M <br />17 -11 X 13 -3 -511 <br />1' <br />o <br />8 8"CLG 8'-8" CLG <br />7 5/8" <br />4'-8" <br />3'-8" 5'-11" 4. 6'-9" 3'-1" V-11" 2'-4 3/4" <br />7 5/8" <br />2X4 KNEE <br />`�" 6" PLUMBING <br />g <br />I <br />WALL, TOP <br />N STACK WALL---------_S6 <br />1 <br />AT 34 1/2" <br />r <br />1CARPET <br />TILE <br />REF <br />�t <br />CV <br />II II I <br />=____ <br />_� <br />00 <br />I <br />KITCHEN <br />1====9-= c o c <br />_ <br />0 <br />14'-1" X 9'-6" <br />IpW <br />8'-8" CLG <br />SINK W/ <br />3 <br />I <br />DISPOSAL <br />I <br />w <br />o <br />J <br />Q <br />-jj A7 2 <br />~ <br />2068 <br />S6 <br />HOOD/ RANG 1 <br />co��� <br />O O <br />O <br />PANTRY <br />c <br />4" 10 <br />(4) 16" <br />o <br />N1 <br />N <br />DP SH <br />\ <br />V_ <br />w IPDWR R <br />8'-8" CLG iv <br />4" INSULATED <br />I 20 MIN FIRE BRG WALL PROTECTIVE <br />p <br />_ <br />r <br />— — — RATED DOOR BOLLARD101 <br />W/ WEATHER STRIP <br />31+7 <br />S3 <br />LO <br />LINE OF <br />— CC <br />N <br />FLOOR <br />— S3 <br />ABV <br />4" INSULATED <br />BRG WALL <br />42" H. <br />V4Vz <br />LOW <br />SLOPED <br />CC <br />10 <br />WALL <br />S3 <br />3 <br />r <br />9------ TWO CAR GARAGE <br />s_-- 20'-1" X 20'-0" <br />A3 <br />36" HIGH7 <br />CONT. <br />RAILING <br />FOYER 6 <br />5 J <br />RPET ------ S3 <br />4 <br />TILE ------ _ <br />3 ------------- LINE OF GARAGE IN <br />00 <br />1 2 I OPEN POSTION <br />LO <br />U�P <br />M <br />l <br />' , � I \ <br />1 <br />I I <br />/ <br />HAT <br />I <br />o <br />1 /2" 7'-4� <br />8 <br />M 00 <br />TEMP. GLASS <br />M <br />4'4` 2'-9 <br />WD 111 � 16070 <br />HB <br />8" <br />V-2" <br />0 <br />SOFFIT <br />ABV <br />_� <br />ENTRY <br />8'-8" <br />X 4'-4" <br />7'-8" 2'-8" 16'-0" 2'-8" <br />8'-8" <br />21'-4" <br />30'-0" <br />�C? <br />m-00 <br />w <br />F... <br />TIE BM 9 <br />AT 8'-8" <br />A7 <br />mbo <br />w <br />I= <br />FIRST FLOOR PLAN - ELEVATION A <br />1 /411 = 1'-0„ <br />0 <br />N <br />NOTE: <br />PROVIDE R-11 F.G. INSULATION IN EXTERIOR WALLS, <br />INCLUDING BEHIND RIM JOIST IN FLOOR ASSEMBLY <br />PROVIDE R-11 F.G. INSULATION IN WALLS ADJACENT <br />TO ATTIC SPACE <br />NOTE: <br />1. SEE SHEET S-11 , S12'187T FOR LINTEL <br />CALLOUTS & DETAILS <br />2. ALL EXTERIOR HDRS AT OPENINGS ARE (2) 2X6'S <br />UNLESS NOTED OTHERWISE <br />9 <br />A7 <br />TOP <br />AT 18'-0" <br />O 9 2'-10 3/4" <br />Q SH 25 <br />HD AT T-3" <br />EGRESS <br />WE � i01, <br />��� <br />PRIN <br />27'-1 1 /4" <br />DRAIN LINE OF <br />SHWR HD ROOF <br />& VALVE %—BELOW <br />(4) 16" <br />R & S <br />N i <br />`r <br />' <br />SH <br />2068 BF <br />----� <br />W <br />Cs <br />i <br />66d, <br />OWNER'S BATH <br />2668 <br />U _j <br />5'-41, <br />5'- 7/8" <br />04 <br />6 <br />FLR <br />OWNER'S SUITE 00 <br />LINE <br />B <br />m <br />, <br />14'-7" X 12'-8" N <br />TB <br />S6 <br />-1 <br />� <br />8'-0" CLG <br />Q Q <br />W.I.C. <br />r <br />, <br />_ <br />WATER <br />N <br />= <br />{ <br />CL SET <br />S & R <br />LO <br />N N <br />i <br />TP <br />(2) 2068 BF <br />R& S <br />N <br />N <br />N <br />I <br />LOFT <br />I „ <br />148'-0' <br />�; <br />I <br />CLG AHU <br />BEDROOM #2 <br />A/C RETURN <br />10'-11" X 10'-01, <br />UNDER DOOR j <br />8'-0" CLG <br />CO <br />S6 <br />M <br />N j�Cn <br />�Q <br />r <br />1 <br />c=now <br />0 <br />4 M <br />4'-11 5/8" <br />ti6�'fL <br />' 3'-8" A3 4'-101' 1'-2" 2'-11" 11" <br />3'-4" <br />2'-10 1/2" 2'-10 3/8" <br />z <br />1 <br />AT <br />60 AFF 6 <br />60" <br />4 <br />1'-3 1/2" <br />N <br />d <br />r 22"x36" <br />- <br />--- <br />CO <br />42" H. <br />16 <br />--- <br />8" <br />UTILITY - ATTIC <br />D 2868 <br />® <br />15 <br />--- <br />FRAME <br />N <br />LOW <br />� 1 ACCESS <br />6 WALL J & — — — <br />" <br />UWALL <br />WALL <br />WALL <br />0 <br />w <br />14 <br />"' <br />U <br />8 A7 <br />a <br />0' <br />W BATH <br />#2 <br />13 <br />---- <br />SLOPED <br />W DRYER <br />U <br />~ <br />A7 <br />12 <br />OW <br />WALL <br />0 VENT <br />2668 <br />TB TP <br />11 <br />10 <br />HANSEN <br />----- <br />BOX <br />2668 <br />R & S <br />3 <br />R&S <br />7 <br />(2)2068BF --_ <br />_ <br />OPENTO <br />17 <br />�n <br />— — — — <br />1668 <br />- - <br />A3 <br />_ <br />BELOW <br />----- <br />(2) 2068 BF <br />36" H. <br />6 <br />N <br />-' <br />CONT <br />Co <br />N <br />N <br />5 <br />RAILING <br />------- <br />(4) 12" <br />4 <br />P SH <br />M <br />00 <br />LO 21 <br />I3---- <br />� <br />coBEDROOMOI <br />I I� <br />#4 <br />BEDROOM#3 <br />M <br />OI 11 <br />8'-0" CLG <br />S6 , <br />8'-0" CLG <br />TYP. <br />Co <br />SH 1 <br />2 34 <br />HD A <br />T-T <br />i <br />ti <br />FRAM <br />WALL' <br />` <br />\ <br />// <br />L--------- <br />-- <br />I <br />4'-4" 4'-4" <br />8'-8" I <br />4" SH 25 <br />FRAMEJ HD AT T-3" <br />WALL EGRESS <br />5'-7 1 /4" 0 10'-4" <br />21'-4" <br />30'-0" <br />SECOND FLOOR PLAN - ELEVATION A <br />1 /4" = 1'-0" <br />/ SH 25 <br />/H D AT 7'-3" <br />EGRESS <br />5'-4 3/4" <br />GENERAL NOTES: <br />ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL <br />FIN AWAY FROM WINDOW FRAME. <br />VERIFY ALL WINDOW AND DOOR ROUGH OPENING <br />SIZES WITH THE MANUFACTURER'S SPECIFICATIONS. <br />INSTALL SQUARE DRYWALL BEADS AT HORIZ & VERT <br />CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS <br />NOTED. <br />USE SQUARE CORNER BEAD AT DRYWALL NICHES & <br />REC CLG DETAILS; REC CLG SURFACES SHALL HAVE <br />SMOOTH FINISH. <br />LOCATE ALL PLUMBING & EXHAUST STACKS BEYOND <br />THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER <br />CODE. <br />ALL ANGLED WALLS TO BE 45° UNLESS NOTED <br />OTHERWISE <br />THE GARAGE IS TO BE SEPARATED FROM ADJACENT <br />LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD <br />AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" <br />THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT) <br />APPLIED TO THE GARAGE SIDE. <br />TOWEL BAR - (T.B.)* = 42" A.F.F. <br />TOWEL BAR ABV. TUB DECK* = 36" ABV. TUB DECK <br />TOILET PAPER DISP. - (T.P.)* = 20" A.F.F. <br />ROD AND SHELF (SGL)- (R/S) = 60" A.F.F. <br />ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F. <br />CORNER SHELF = 56" A.F.F. <br />MEDICINE CABINET - (M.C.) = 75" TO TOP OF <br />CABINET A.F.F. <br />*PROVIDE 2X BLOCKING IN WALL AT ALL LOCATIONS <br />FOR T.B. AND T.P. <br />WALL LEGEND: <br />ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR <br />RESISTANT COMPONENTS. <br />8" CMU W/ 1X3 PT FURRING STRIP, <br />3/4" INSULATION BOARD, 1/2" GYP <br />8" CMU <br />NON -BEARING 2X4 STUD W/ 1/2" GYP, <br />BEARING WALL 2X4 16" O.C. <br />17777777777777777771 <br />W/ 1/2" GYP. <br />❑ = FILLED CELL W/(1) #5 VERTICAL <br />®= FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB <br />= FILLED CELL W/(2) #5 VERTICAL <br />O = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR) <br />STAIR DATA <br />STAIR <br />MARK <br />RISERS <br />TREADS <br />LANDINGS <br />TOTAL RISE <br />A� <br />16 AT 7 9/16" <br />14 AT 10" <br />1 <br />10'-0 3/4" <br />SQUARE FOOTAGE: <br />AREA <br />PROPOSED <br />FIRST FLOOR LIVING <br />780 <br />SECOND FLOOR LIVING <br />1090 <br />TOTAL LIVING SQ FT 1870 <br />ENTRY <br />38 <br />GARAGE <br />443 <br />TOTAL SQ FT 2351 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2X4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2X6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />JUL 2 1 2023 <br />Virtual Review Assist, Ina / <br />plans Review completed and app�ved <br />for compliance with the 2020 FBC 7th Editioli <br />by Debra Anne Klahr PX2300 <br />ALLOWABLE WIND SPEED DESIGN PRESSURE <br />(140 mph, enclosed, 3 sec. gust, 2.1/12 to 6.9.12 pitch, <br />Exposure C, Height=30 ft, Importance Factor=1.0, End <br />Zone= 4 ft) <br />As per Florida Building Code 7th edition (2020), <br />Residential Table R301.2 (4) (Wind Speed Conversions) <br />and ASCE 7-10 Methods <br />WALL <br />TRIBUTARY <br />AREA (ft)2 <br />INTERIOR <br />END <br />10 <br />39.4 <br />-42.1 <br />39.4 <br />-51.8 <br />20 <br />37.6 <br />-40.5 <br />37.6 <br />-48.6 <br />50 <br />35.2 <br />-37.3 <br />35.2 <br />-43.7 <br />100 <br />33.4 <br />-35.6 <br />33.4 <br />-40.5 <br />GARAGE DR <br />30.0 <br />-33.9 <br />30.0 <br />-33.9 <br />M <br />N <br />O <br />N <br />ib <br />n <br />*, <br />CD <br />00 <br />LO <br />-� , <br />€.x� <br />'� ° i', <br />t { <br />z <br />W <br />00 <br />w <br />W <br />W <br />0 <br />z <br />> 0 F1 o <br />W 10 <br />0 C-) N d <br />t}il V O co u a <br />-0 — M <br />0 s <br />oo <br />.� O o m Q <br />w 0 <br />QN <br />70 i 00E �2' <br />V a ) <br />W <br />0LIS 0 <br />J= <br />(S <br />02 V0�0 <br />�F- <br />0LU WF-¢ x2g z1Oq�- <br />Q U <br />¢0X Jco0'cn <br />~ <br />=°�ZLLLL0Z20 ¢�Z <br />oomZ=o <br />oZ <br />D <br />Lu zRO <br />L n W W ZpwQ0Z0co Q <br />LU <br />� <br />QoW <br />H�LL ¢¢ <br />� o =o¢Z <br />U_¢ 0 ¢u <br />f <br />w <br />O <br />O <br />N <br />zW <br />O <br />�M O <br />M <br />Lr) <br />� UU_� <br />W Ln <br />>- <br />Q 06 <br />�— <br />Z � <br />W <br />O <br />9.0 <br />N <br />N <br />N <br />o <br />A <br />4 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />0 <br />0 <br />0 <br />o <br />CO <br />of <br />co <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />O <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />A <br />C6(� <br />N <br />' <br />r <br />O <br />ap <br />N <br />LO46 <br />O0 <br />0 <br />0 <br />0 <br />66 <br />O <br />N <br />' <br />L <br />' <br />� <br />0 <br />i <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />n <br />LO <br />CO w <br />Z Z <br />—z2 <br />� <br />WU�> <br />0 C <br />TT <br />Q <br />�o�o <br />�Q <br />V ,o <br />- <br />0 <br />Of W <br />zX�� <br />=m=OZ <br />F- Z <br />Z J <br />i-2ZZX <br />z z <br />LO <br />W Imo: <br />Q <br />O <br />0 <br />U <br />-S 2 z <br />0- w <br />® <br />Z <br />Z Z <br />'\eC' <br />z <br />F- 0 <br />CL <br />®V <br />O <br />c <br />a <br />Z <br />z <br />w <br />UjCY) <br />M <br />N <br />O <br />7—LAST <br />PLOT DATE <br />> <br />May. 8, 23 <br />z <br />Q <br />1ST & 2ND FLOOR <br />J <br />PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.