My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6445 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6445 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 7:44:34 PM
Creation date
2/19/2025 8:26:28 AM
Metadata
Fields
Template:
Building Plans
Street #
6445
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7/8" <br />3-COAT SAND FINISH STUCCO <br />ON SELF FURRING LATH ON 2- <br />LAYERS OF WATER RESISTIVE <br />BARRIER COMPLYING WITH <br />ASTM E2556, TYPE 1 (TYP)— <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED -- <br />WEEP SCREED <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL <br />18 GA HEAD WALL FLASHING <br />TO EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />SHINGLE ROOF PER SPECS — <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />3++= 1 +-01+ <br />TAPE EDGE OF HEAD <br />WALL FLASHING <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />WALL SHEATHING PER PLAN--------__. <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED----_ <br />WEEP SCREED <br />HEAD WALL TRIM FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL— <br />CONT BUTYL TAPE SEALANT PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />'Z' CLO <br />STANDING SEAM METAL <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />mmEd <br />9 <br />z <br />00 <br />HEAD WALL <br />f. <br />a_� 11%\m <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER <br />RESISTIVE BARRIER <br />OVER WEEP SCREED <br />TAPE EDGE OF COUNTER <br />FLASHING <br />WEEP SCREED <br />COUNTER FLASHING <br />CONT SELF ADHERED <br />FLASHING TURN 3" UP WALL <br />SHINGLE PER SPECS <br />STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />TAPE EDGE OF RAKE <br />WALL FLASHING <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED---.: <br />RAKE WALL STEP FLASHING TO <br />EXTEND MIN 8" BEYOND <br />UNDERLAYMENT <br />FIELD BEND PANEL UP 1 1/2" <br />CONT BUTYL TAPE SEALANT 7PER <br />MANUFACTURER INSTALLATION <br />INSTRUCTIONS <br />STANDING SEAM METAL \ <br />ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP WALL MIN <br />ROOF SHEATHING <br />NOTE: PER PLAN <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE CONT SELF ADHERED <br />OUT OF CORROSION FLASHING TURN 3" UP WALL <br />-RESISTANT MATERIAL <br />HEAD WALL <br />FLASHING REQUIREMENTS i <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A N <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />TAPE EDGE OF HEAD SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. 0 > O U <br />WALL FLASHING O LO +� <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED s- <br />FIBER CEMENT SIDING N <br />FIBER CEMENT SIDING AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER O Q O' <br />PER ELEVATIONS WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE _� ca I <br />PER ELEVATIONS EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO -'--' O <br />WALL SHEATHING PER PLAN � V +� to � <br />WALL SHEATHING PER PLAN THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. c6 cz <br />SHINGLE WATER <br />SHINGLE WATER oo RESISTIVE BARRIER R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO. ASPHALT FELT, FREE FROM N <br />RESISTIVE BARRIER OVER FLASHING HCLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED O Q O <br />OVER FLASHING WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL O u- <br />TAPE EDGE OF COUNTER EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE CQ O ''-' `a-- cz <br />FLASHING UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE .U) -0 E O OO <br />STARTER STRIP - <br />00 CO JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED to (2)L Q <br />CONT SELF ADHERED STARTER STRIP MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE cWz !cz C5_ <br />FLASHING TURN 3" UP WALL COUNTER FLASHING BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT -0 <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />18 GA HEAD WALL FLASHING CONT SELF ADHERED TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />TO EXTEND MIN 8" BEYOND FLASHING TURN 3" UP WALL APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />UNDERLAYMENT ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />z SHINGLE PER SPECS <br />SHINGLE ROOF PER SPECS R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />00 STEP FLASHING TO INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />ROOF UNDERLAYMENT TO EXTEND MIN 8" BEYOND SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />z TURN UP WALL MIN 8" UNDERLAYMENT z PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF SHEATHING ROOF UNDERLAYMENT TO PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />PER PLAN TURN UP WALL MIN 8" 00 ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING <br />PER PLAN `' EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />6 WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />6 6" DESIGNED DRAINAGE SPACE. <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS, <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL HEAD WALL RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />- ROOF TO WALL - SHINGLE TO SIDING W P 13 ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />W P 12 <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />3++ 1 +_0++ SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />TAPE EDGE OF HEAD GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />WALL FLASHING ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT, FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />FIBER CEMENT SIDING WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />FIBER CEMENT SIDING PER ELEVATIONS OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />PER ELEVATIONS FOLLOWING LOCATIONS: <br />TAPE EDGE OF RAKE <br />WALL FLASHING 1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />WALL SHEATHING PER PLAN AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />WALL SHEATHING PER PLAN FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />SHINGLE WATER SHINGLE WATER FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />RESISTIVE BARRIER RESISTIVE BARRIER SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OVER FLASHING MIN 8" OVER FLASHING MIN 8" OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />CO STARTER STRIP <br />00 STARTER STRIP EO 1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />RAKE WALL STEP FLASHING TO INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />EXTEND MIN 8" BEYOND FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />HEAD WALL TRIM FLASHING UNDERLAYMENT <br />TO EXTEND MIN 8" BEYOND INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />UNDERLAYMENT FIELD BEND PANEL UP 1 1/2" INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />67 <br />CONT SELF ADHERED CONT BUTYL TAPE SEALANT PER WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />FLASHING TURN 3" UP WALL— MANUFACTURER INSTALLATION RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />INSTRUCTIONS FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD f <br />CONT BUTYL TAPE SEALANT PER AND SIDES. <br />MANUFACTURER INSTALLATION _ Z' CLOSURE — <br />INSTRUCTIONS 001.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />STANDING SEAM METAL a0 REGISTERED DESIGN PROFESSIONAL. <br />Z' CLOSURE ROOF PER SPECS 1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />STANDING SEAM METAL 1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />ROOF PER SPECS ROOF UNDERLAYMENT TO 250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />TURN UP WALL MIN 8" 2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH JUL 2 1 20 <br />ROOF UNDERLAYMENT TO PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />TURN UP WALL MIN 8" <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />ROOF SHEATHING ROOF SHEATHING COPINGS AND SILLS. <br />PER PLAN PER PLAN 4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />CONT SELF ADHERED 5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH T <br />FLASHING TURN 3" UP WALL WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION <br />Virtual Review Assist Inc. <br />6.6 AT WALL AND ROOF INTERSECTIONS. plans Review completed an I approved <br />RAKE WALL HEAD WALL RAKE WALL 7.7 AT BUILT-IN GUTTERS. for compliance b with the 2020 C 7th Edition t, <br />ROOF TO WALL - STANDING SEAM ROOF TO SIDING THESE DETAILS ARE GENERIC AND MEANT TO SHOVAbENERAL Lahr 2300 <br />WP 14 3++_ 1 +_0++ WP 15 FLASHING AND WATERPROOFING METHODS TO BE USED. <br />U <br />cu <br />c <br />cz <br />0 <br />0 <br />O <br />L <br />U) <br />+� W <br />SHEET NO. <br />WR 2.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.