My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6461 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6461 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:17:54 PM
Creation date
2/19/2025 8:26:58 AM
Metadata
Fields
Template:
Building Plans
Street #
6461
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /4" = 1'-011 <br />LINE OF ROOF <br />Ml nlni <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /4" = 1 1 <br />-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS -WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />Virtual Revie leted4and a pro,, <br />Plans Review Comp <br />for compliance <br />by Debra n <br />with neeKlahbr PX23pp Ed <br />A <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />T <br />i <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET r> <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S <br />SMOKE DETECTOR <br />V-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />11 OV DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br /><> STRUCTURED WIRE OUTLET <br />-� SWITCH AT 36" <br />69 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />-[� PUSH-BUTTON DOORBELL <br />A3- CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />-�- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />C, 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4� " USED IF 50W PAR30 NFL 6WHITE BAFFLE <br />C APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C` 50W PAR20 NFL 4" MINI ROUND RECESS <br />C 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />i ' CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9724;R 24" VANITY LIGHTING <br />F-,-=36`F� 36" VANITY LIGHTING <br />FF--48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Ci EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5-0" ABV FINISH FLOOR <br />O CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />1= MASTER STATION <br />_ffig-0 ELEC PANEL <br />VACUM OUTLET AT 12" <br />WAI CEILING RETURN AIR <br />E3 A/C REGISTER <br />OT THERMOSTAT <br />03 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />M <br />N <br />rn <br />.i <br />LO <br />00 <br />LO <br />� <br />� T <br />s j 00 <br />Q <br />IrtFs<1w <br />O <br />;may. <br />w <br />z <br />¢ <br />V) N L0 F, <br />i'0 <br />o U <br />W <br />0 C7 !_1!00 d <br />'Ln Z D � u P <br />N V -0 r M <br />s <br />moo o <br />_` <br />0U_' a <br />s U�� <br />} <br />•Vn,) V w QN c <br />L p E <br />co <br />7W <br />LLIwOV <br />❑ <br />zwW¢ wE❑- <br />w0es��2OYw z <br />O UOO <br />JQ <br />QxJw�a9OZtRoomoz <br />UJ <br />OO(5w0> <br />z <br />-w x QCy <br />L5wZO <br />Q~QO1QZLu°alL <br />0Q Q <br />0Q QQz <br />O <br />E-Qu <br />O <br />Z N <br />Ow <br />P- <br />U) f r-- <br />�F--MO <br />Q M <br />J LO <br />UILL ti <br />LO <br />0 M_ <br />00 <br />Z V I¢- <br />w <br />W <br />J O <br />wj <br />0 <br />0 <br />0 <br />ti <br />4 <br />4 <br />O <br />N <br />O <br />CAI <br />0 <br />0 <br />0 <br />O <br />0 <br />CO <br />M <br />L- <br />T <br />N <br />N <br />N <br />N <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />6 <br />00 <br />600 <br />A <br />r <br />O <br />LOCO <br />Oo <br />o© <br />0 <br />0 <br />o <br />1 <br />N� <br />> <br />o <br />o <br />ca <br />CD <br />0 <br />0 <br />0 <br />N <br />M <br />to <br />CD, I <br />I-- <br />LO <br />I <br />CO w <br />Z Z <br />O <br />0wc) <br />O� <br />W0I_ <br />0 <br />Vo�o <br />Q <br />'' ^^ <br />V) <br />Oa=S <br />W I— <br />V , <br />Z <br />�Q <br />Q <br />wco <br />I—oz <br />V <br />Z J <br />N <br />>- <br />z0 <br />M <br />Z z <br />LO <br />w N <br />Og2Z <br />O <br />Q <br />vWzZ <br />z <br />TQO <br />z <br />U <br />U <br />00 <br />In <br />W <br />� <br />Z <br />A6 <br />z <br />z <br />w <br />J <br />M <br />Uj <br />o <br />T- <br />LAST PLOT DATE <br />> <br />May. 9, 23 <br />zf� <br />0 <br />1 ST & 2ND FLOOR <br />ELECTRICAL PLAN <br />A <br />- ---- <br />_. i L .,. . � JI, ;mlln'.'.lu,a611111 t I All III L P. I . !. I L! ,d -1 I <br />
The URL can be used to link to this page
Your browser does not support the video tag.