My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6471 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6471 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:59:25 AM
Creation date
2/19/2025 8:27:20 AM
Metadata
Fields
Template:
Building Plans
Street #
6471
Location
Beverly Hills Dr
Contractor
Lennar Home
Building Plans - Permit #
4145
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ti <br />V <br />ri <br />a <br />n <br />ABBREVIATIONS <br />ABV <br />-ABOVE <br />AFF <br />- ABOVE FINISH FLOOR <br />AHU <br />- AIR HANDLER UNIT <br />A/C <br />- AIR CONDITIONING <br />ALUM <br />- ALUMINUM <br />AT <br />- ALUMINUM THRESHOLD <br />AB <br />- ANCHOR BOLT <br />AVG <br />-AVERAGE <br />BFE <br />- BASE FLOOD ELEVATION <br />BM <br />-BEAM <br />BLK <br />-BLOCK <br />BLDG <br />- BUILDING <br />BRD <br />-BOARD <br />BRG <br />- BEARING <br />BTM <br />-BOTTOM <br />BUC <br />- BUILT UP COLUMN <br />CAB <br />- CABINET <br />CD <br />- CONSTRUCTION DOCUMENTS <br />CLG <br />- CEILING <br />CLG HT <br />- CEILING HEIGHT <br />CEMT <br />- CEMENTITIOUS <br />CL <br />- CENTERLINE <br />COL <br />-COLUMN <br />CONC <br />-CONCRETE <br />CMU <br />- CONCRETE MASONRY UNIT <br />CONST <br />- CONSTRUCT OR CONSTRUCTION <br />CONT <br />- CONTINUOUS OR CONTINUES <br />CTR <br />-CENTER <br />cJ <br />- CONTROL JOINT <br />DP <br />- DEEP OR DEPTH <br />DTL <br />- DETAIL <br />DIA <br />- DIAMETER <br />DIM <br />- DIMENSION <br />DISCON <br />- DISCONNECT <br />DW <br />- DISHWASHER <br />DR <br />-DOOR <br />DBL <br />- DOUBLE <br />DWG <br />- DRAWING <br />EA <br />-EACH <br />ELEC <br />- ELECTRICAL <br />ELEV <br />-ELEVATOR <br />EQ <br />-EQUAL <br />EQUP <br />- EQUIPMENT <br />EXP JT <br />- EXPANSION JOINT <br />EXT <br />- EXTERIOR <br />FIN FLR <br />- FINISHED FLOOR <br />FIN <br />- FIN <br />EW <br />- EACH WAY <br />FG <br />- FIXED GLASS <br />FD <br />- FLOOR DRAIN <br />FE <br />- FIRE EXTINGUISHER <br />FLR <br />- FLOOR <br />FLOUR <br />- FLUORESCENT <br />�! <br />FTG <br />- FOOTING <br />- <br />FR DR <br />- FRENCH DOOR <br />GALV <br />- GALVANIZED <br />JUN u 2 202Z <br />GA <br />-GAUGE <br />GB <br />- GRAB BAR <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR <br />GLS <br />-GLASS <br />GWB <br />- GYPSUM WALL BOARD <br />GYPBRD <br />- GYPSUM BOARD <br />HD <br />-HEAD <br />HVAC <br />- HEATING, VENTILATING, AIR CONDITIONING <br />HT <br />- HEIGHT <br />HB <br />- HOSE BIB <br />HC <br />- HANDICAP <br />INSUL <br />- INSULATION <br />INT <br />- INTERIOR <br />LVL <br />- LAMINATED VENEER LUMBER <br />LT <br />- LAUNDRY TUB <br />LGT <br />- LIGHT <br />MAX <br />- MAXIMUM <br />MATL <br />- MATERIAL <br />MFR <br />-MANUFACTURER <br />MECH <br />- MECHANICAL <br />MTL <br />- METAL <br />MC <br />- MEDICINE CABINET <br />MIN <br />- MINIMUM <br />SYMBOL LEGEND: <br />MLDG - MOULDING <br />MNT - MOUNT OR MOUNTING <br />MO <br />- MASONRY OPENING <br />MUNT <br />- MUNTINS <br /># <br />-NUMBER <br />OC <br />- ON CENTER <br />OGD <br />- OVERHEAD GARAGE DOOR <br />OPNG <br />- OPENING <br />OPP <br />- OPPOSITE <br />OPT <br />- OPTIONAL <br />OH <br />- OVER HANG <br />OH CABS- OVERHEAD CABS <br />PNT <br />- PAINT FINISH <br />PTD <br />- PAINTED <br />PED <br />-PEDESTAL <br />PERF <br />-PERFORATED <br />PLT <br />-PLATE <br />PLYWD <br />- PLYWOOD <br />PKT <br />-POCKET <br />LB <br />-POUND <br />PSF <br />- POUNDS PER SQUARE FOOT <br />PSI <br />- POUNDS PER SQUARE <br />PT <br />- PRESSURE TREATED <br />PB <br />- PUSH BUTTON <br />REF <br />- REFRIGERATOR <br />RECP <br />-RECEPTACLE <br />REINF <br />- REINFORCING <br />REQD <br />- REQUIRED <br />R/A <br />- RETURN AIR <br />RO <br />- ROUGH OPENING <br />RS <br />- ROUGH SAWN <br />SC <br />- SOLID CORE <br />SCP <br />-SCUPPER <br />SCRN <br />-SCREEN <br />SIM <br />- SIMILAR <br />SHLVS <br />-SHELVES <br />S/R <br />- SHELF & ROD <br />SH <br />- SINGLE HUNG WINDOW <br />SGD <br />- SLIDING GLASS DOOR <br />SPECS <br />- SPECIFICATIONS <br />SQ FT <br />- SQUARE FEET <br />SQIN <br />-SQUARE INCH <br />STD <br />-STANDARD <br />STL <br />-STEEL <br />STRUCT <br />-STRUCTURAL <br />TEMP <br />-TEMPERED <br />THK <br />- THICK OR THICKNESS <br />TB <br />- TOWEL BAR <br />TOC <br />- TOP OF CONCRETE <br />TOM <br />- TOP OF MASONRY <br />TOP <br />- TOP OF PLATE <br />TP <br />- TOILET PAPER HOLDER <br />TYP <br />- TYPICAL <br />UNO <br />- UNLESS NOTED OTHERWISE <br />VAC <br />-VACUUM <br />VAL <br />-VALANCE <br />VERT <br />- VERTICAL <br />VIF <br />- VERIFY IN FIELD <br />VTR <br />-VENT THROUGH ROOF <br />V <br />-VOLT <br />WC <br />- WATER CLOSET <br />WH <br />- WATER HEATER <br />WL <br />- WIND LOAD <br />WP <br />- WEATHERPROOF <br />WWM <br />- WELDED WIRE MESH <br />W <br />- WIDE OR WIDTH <br />WDW <br />- WINDOW <br />W/ <br />- WITH <br />WD <br />- WOOD <br />CA = <br />STAIR CALL OUT <br />' HEIGHT OF <br />STEP DOWN <br />\\ <br />= <br />FOOTING CALL OUT - <br />SEE FOOTING <br />STEP <br />STEP <br />SCHEDULE <br />OUT <br />_-ARROW SHOWS <br />O= <br />KEYNOTE CALL OUT <br />DIRECTION OF VIEW <br />1 ELEV NUMBER <br />A9 <br />CD= <br />PRE -CAST LINTEL CALL <br />OUT - SEE LENTEL <br />SHEET NUMBER <br />EXTERIOR <br />SCHEDULE <br />ELEVATION MARKER <br />l <------ELEV NUMBER <br />LEDGER CALL OUT - SEE <br />SHEET NUMBER <br />LEDGER SCHEDULE <br />4 A 55 2 <br />------ARROW SHOWS <br />3 DIRECTION OF VIEW <br />MULTI VIEW INTERIOR <br />ELEVATION MARKER <br />Al3E--SHEET NUMBER <br />1 INT ELEV NUMBER <br />ARROW SHOWS <br />DIRECTION OF VIEW <br />INTERIOR ELEVATION <br />MARKER <br />ARROW SHOWS <br />DIRECTION OF CUT <br />1 <br />All SECTION NUMBER <br />SHEET NUMBER <br />LOCATION OF CUT <br />SECTION <br />MARKER <br />GENERAL NOTES <br />THE FOLLOWING TECHNICAL CODES SHALL APPLY: <br />2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, NFPA 70 NATIONAL ELECTRICAL CODES 2017 <br />2020 FBC PLUMBING RESIDENTIAL SECTION 604 <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WATER -FLOW RATE. <br />PUBLIC FACILITIES LAV 0.5 G.P.M. <br />PRIVATE FACILITIES LAV 2.2 G.P.M. <br />SHOWER HEADS 2.5 G.P.M. <br />3. ALL PLUMBING WATER LINES <br />TO BE CPVC <br />VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO <br />JOBSITE CONDITIONS <br />THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL <br />CODE <br />❑ PORCHES AND BALCONIES <br />CHAP. 3 <br />❑ HANDRAILS - CHAP. 3 <br />❑ GUARDRAILS - CHAP. 3 <br />❑ STAIRS - CHAP. 3 <br />❑ CHIMNEY & FIREPLACE <br />CHAP. 10 <br />❑ EGRESS WINDOWS <br />CHAP. 3 <br />5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />INSTALLATION. <br />SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />OVERHEAD GARAGE DOORS, AND ROOFING. <br />6. ALL DOORS INTERIOR & EXTERIOR ARE 6-8" UNLESS OTHERWISE NOTED ALL <br />SHOWER ENCLOSURES TO BE TEMPERED GLASS <br />7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR <br />TO BE TEMPERED GLASS. (SECTION R308) <br />DIMENSIONING: <br />A. DIMENSIONS INDICATED ARE TO: <br />A.1. CMU WALL: OUTSIDE FACE OF WALL <br />A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />CORE -STUD <br />A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. <br />FURRING\ <br />A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD <br />A.4. WINDOW OPENINGS: <br />A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />A.5. DOOR OPENINGS: <br />A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED <br />FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR <br />FRAME <br />A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER <br />OF DOOR <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH <br />SURFACE TO FINISH SURFACE <br />A.6.1. EXAMPLE: T-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND <br />PLUMB. <br />C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: <br />C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES <br />C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />C.3. FRAMED WALLS EXTERIOR <br />CA. FRAMED WALLS INTERIOR <br />C.5. DOORS AND WINDOWS <br />D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />UNLESS OTHERWISE NOTED <br />E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE <br />STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />DRAWINGS. <br />LE N NARam <br />LENNAR TAMPA DIVSION <br />4600 W CYPRESS ST, SUITE 200 <br />TAM PA, FL 33607 <br />813.574.5700 <br />2382 ADS <br />1V»C;0.1CCW[Q :/_1k[ei <br />VERSION <br />DESCRIPTION OF CHANGES <br />1.0 <br />CLIENT CHANGES <br />2.0 <br />FLORIDA BUILDING CODE 6TH EDITION (2017) UPDATED <br />3.0 <br />MASTER CHANGE UPDATE <br />4.0 <br />PERMIT COMMENT REVISION <br />5.0 <br />TRUSS CONNECTOR REVISION <br />6.0 <br />FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATED <br />7.0 <br />UPDATE DETAIL CALL OUT FOR 2ND FLOOR WINDOW AT BEDROOM 5 <br />8.0 <br />ADDING K, L, M ELEVATIONS <br />INDEX OF DRAWINGS <br />SHT NO: TITLE <br />CS <br />COVER SHEET <br />Al <br />FOUNDATION PLAN <br />A2 <br />1 STAND 2ND FLOOR PLAN <br />A2.1 <br />SALES OFFICE PLAN <br />A3 <br />STAIR DETAILS <br />A4 <br />2ND FLOOR - ROOF FRAMING PLAN <br />A5 <br />EXTERIOR ELEVATIONS & ROOF PLAN <br />A6 <br />1 ST & 2ND FLOOR ELECTRICAL PLANS <br />A7 <br />INTERIOR ELEVATIONS <br />SNO <br />STRUCTURAL NOTES <br />SN1 <br />STRUCTURAL NOTES <br />S3 <br />FOUNDATION DETAILS <br />S4 <br />FRAME WALL DETAILS <br />S5 <br />STRUCTURAL DETAILS <br />S6 <br />WALL SECTION DETAILS <br />SS <br />RETRO FIT DETAILS <br />ST <br />STAIR DETAILS <br />S11 <br />PRECAST DETAILS <br />S12 <br />PRECAST DETAILS <br />PA 1.0 <br />PRODUCT APPROVAL <br />PA 1.1 <br />PRODUCT APPROVAL <br />PA 1.2 <br />PRODUCT APPROVAL <br />PA 1.3 <br />PRODUCT APPROVAL <br />SH 1.0 <br />HURRICANE SHUTTERS <br />SH 1.1 <br />HURRICANE SHUTTERS <br />SH 1.2 <br />HURRICANE SHUTTERS <br />SH 1.3 <br />HURRICANE SHUTTERS <br />SH 1.4 <br />HURRICANE SHUTTERS <br />SH 1.5 <br />HURRICANE SHUTTERS <br />WP 1.0 <br />WATERPROOFING DETAILS <br />MAY? 4 <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Flans Review completed and approved <br />Mr compliance with the 2020 FBC 7th <br />Eu:f"tPon by Debra Anne Klahr PM00 <br />NOTICE TO BUILDER & ALL SUBCONTRACTORS <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE <br />BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />f <br />a° <br />N <br />O <br />N <br />co <br />ip <br />S <br />Ill <br />�V <br />�{ AR001 0 <br />Q <br />° <br />zb <br />0 <br />'t <br />w <br />o <br />z <br />Q <br />^ F <br />} <br />Ln <br />t� 70 °D M <br />E.L- " r o <br />O u o <br />_ O <br />O �o Q <br />i U6� <br />�tnn` V w Q:;� <br />0 EM <br />W L <br />O� a <br />r- F- a -o <br />W <br />W <br />w <br />WWQ W `� wg�ez <br />U-00,0-j0 <br />LL <br />Q ¢j F- U <br />QOX J0)0�of <br />=�D�OLL'O-OOmQZQQ <br />C�00 <br />(n O Z <br />11) Fn Yo_Zz�pW00 <br />J Q Q 0 W Q- W z d <br />L� <br />Q0W g�F �YZ�Q Q <br />C)0 a�Q� <br />oa <br />>1 <br />O <br />O <br />CV <br />Z <br />OW <br />i(no <br />F- cM O <br />Q U) M � <br />qq- <br />LL <br />QWQLt? <br />a M <br />aU<00 <br />Z F- <br />W <br />W <br />JC:) <br />O <br />N <br />N <br />0 <br />N <br />N <br />0 <br />0 <br />m <br />IV-� <br />W <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />CD <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N. <br />N� <br />lob <br />A <br />a0 <br />CDN <br />A <br />O <br />M <br />M <br />0 <br />cr <br />0 <br />ai <br />0 <br />� <br />0 <br />r <br />�- <br />CD <br />(� <br />V <br />C <br />N <br />c) <br />M <br />o <br />d' <br />CD <br />L6 <br />o <br />G6 <br />C) <br />I� <br />1 1 <br />CO <br />rn <br />w <br />Z Z <br />O <br />O <br />_ <br />WWF-> <br />ow%n <br />w <br />o <br />�O--o- <br />oWo <br />Q <br />OWHQ <br />LO <br />-0 <br />//� <br />VJ <br />zW <br />h <br />r <br />< <br />Q <br />=moZ <br />Z <br />N <br />('O!zIII <br />z <br />00 <br />��zw <br />M <br />Z Z LL <br />N <br />0 <br />a <br />0- W <br />WZZ <br />Z <br />Y<o <br />QU <br />J <br />a <br />OU <br />0 <br />W <br />� <br />Q <br />Z <br />z <br />w <br />W <br />N <br />N <br />LAST PLOT DATE <br />O <br />Apr. 11, '22 <br />Z <br />0 <br />COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.