ELECTRICAL SPECIFICATION 150A/2 LC NENTTERER <br />PANEL CENTER <br />DOOR <br />NOTES: <br />#14 to lights 8 outlets <br />NEMA 1 It #12 to appliances and GFI <br />ELECTRICAL CONTRACTOR 150 AMP/ <br />200 AMP 0 #10 to WH <br />MUST VERIFY WITH THE 00 #8 to Range <br />SPECIFICATIONS FOR THE TYPE 10 #6 to HVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. MAIN T <br />0 50=2/0 <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />IDisconnectl <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />11-11. <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />FVwF <br />HALF -SWITCHED DUPLEX OUTLET <br />Ftzbv <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />,Qr <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />I� <br />ELECTRIC METER <br />awl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />l✓ J <br />OPT. CEILING FAN <br />w <br />(1) PHONE LINE, (1) DATA PORT <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=l'-0" <br />r-i <br />ii�" <br />Cv <br />0 <br />o y <br />�- o <br />a..0- <br />u Cl) <br />o.- <br />cp <br />cV t <br />10 is o l <br />a� a> <br />t <br />G <br />' 3 ro <br />L <br />3a+ <br />m W <br />67 <br />U <br /><a <br />s. <br />G E <br />co a <br />C% u <br />a <br />C14 <br />C14 <br />O <br />N <br />M <br />LC� <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />rn <br />a <br />cos <br />C14 C� CD <br />C <br />-w coo0) N N # <br />'Z J <br />ti <br />M v W <br />LL W <br />Z <br />ca JLLU a <br />— a a le <br />m c <br />o <br />N O <br />W <br />W <br />o <br />��rnm M Lu <br />LL Z <br />J <br />LO MZ d k <br />ZN <br />OU <br />W <br />00 <br />❑ ❑ <br />z N M <br />o g <br />z 00 <br />z <br />Q <br />J <br />Cl y� <br />N <br />M <br />� /� <br />V ! <br />'2'n! to <br />O <br />(1)(0 <br />V <br />LU <br />� <br />V <br />0 <br />W g <br />�N <br />= ) <br />in <br />® <br />U <br />w <br />g <br />_ I <br />U 0 <br />c �' 0 <br />Q 0 <br />° <br />_ Q <br />so <br />� <br />Z <br />M <br />O <br />Z <br />a <br />U- <br />to Ei <br />wo <br />Wo <br />Z <br />a� <br />Z® <br />Q <br />E <br />0 <br />Z <br />(t) <br />I— <br />� <br />¢< <br />00 <br />o=� <br />�¢ <br />aZ <br />N � <br />wo <br />ao <br />¢w <br />p <br />N <br />- <br />a <br />Y <br />U <br />ym <br />mo <br />O <br />Z <br />Z <br />< ° <br />aw <br />Z Z <br />u) <br />a <br />o� <br />W <br />Z <br />a <br />mw <br />W <br />�I <br />U <br />0 <br />�o <br />oz <br />T,= <br />=� <br />�O <br />o <br />CID <br />V <br />w <br />z¢ <br />aso <br />J� <br />O <br />y <br />0 (0 <br />Ii <br />L <br />rn <br />cm <br />cc <br />Q <br />(0 <br />F-- <br />G <br />� r <br />N <br />j <br />I <br />Cr <br />U <br />m <br />m <br />L , <br />¢I <br />4-+ <br />0 <br />N <br />0) <br />o <br />G <br />00 <br />N <br />T <br />O L <br />Y <br />O 00 <br />i� <br />LO <br />Z <br />m <br />Z <br />� <br />E d- <br />N <br />y <br />m <br />c <br />a <br />E <br />ci0 <br />a o <br />JOB <br />NO : <br />22-06462 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />