My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6481 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6481 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 2:11:23 PM
Creation date
2/19/2025 8:28:08 AM
Metadata
Fields
Template:
Building Plans
Street #
6481
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV ABOVE MLDG -MOULDING <br />VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />- <br />AFF - ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING THE FOLLOWING TECHNICAL CODES SHALL APPLY: 1.0 PLAN REVISIONS CS COVER SHEET <br />AHU - AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN N <br />A/C - AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING , MECHANICAL, FUEL GAS, 2.0 PLAN REVISIONS A2 1ST AND 2ND FLOOR PLAN A N <br />ALUM -ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 00 <br />3.0 TRUSS CONNECTOR REVISION A3 STAIR DETAILS �, <br />AT - ALUMINUM THRESHOLD OC - ON CENTER <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 A4 FRAMING PLANS A <br />AVG -AVERAGE 1. TANK TYPE WATER CLOSET VOLUME 4.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE A5 EXTERIOR ELEVATIONS & ROOF PLAN �' �n <br />OPNG - OPENING A6.1 1ST FLOOR ELECTRICAL PLAN `V° 00 <br />BFE -BASE FLOOD ELEVATION OPP -OPPOSITE <br />BM -BEAM OPT - OPTIONAL 1.6 GALLONS 5.0 ADDING K, L & M ELEVATIONS A6.2 2ND FLOOR ELECTRICAL PLAN <br />BLK -BLOCK OH - OVER HANG 6.0 ADDED SHEETS WP2.0 AND WP2.1 TO SHEET INDEX SNO STRUCTURAL NOTES r` <br />2. WATER -FLOW RATE. SN1 STRUCTURAL NOTES <br />BLDG -BUILDING OH CABS- OVERHEAD CABS PUBLIC FACILITIES LAV 0.5 G.P.M. Y� 4 ¢ <br />BRD -BOARD PNT - PAINT FINISH c7 " z <br />` <br />BRG -BEARING PTD -PAINTED PRIVATE FACILITIES u4V 2.2 G.P.M. S3 FOUNDATION DETAILSE�� <br />BTM -BOTTOM PED -PEDESTAL SHOWER HEADS 2.5 G.P.M. S4 FRAME WALL DETAILSS5 STRUCTURAL DETAILS ' O <br />BUC - BUILT UP COLUMN PERF -PERFORATED Oil �� <br />CAB - CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES S6 WALL SECTION DETAILS <br />CD -CONSTRUCTION DOCUMENTS PLYWD -PLYWOOD TO BE CPVC <br />SS RETRO FIT DETAILS ®' _ <br />CLG - CEILING PKT -POCKET ST STAIR DETAILS w <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO S1 l PRECAST DETAILS ` <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S12 PRECAST DETAILS Q <br />CL - CENTERLINE PSI - POUNDS PER SQUARE <br />PA 1.0 PRODUCT APPROVAL <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA 1.1 PRODUCT APPROVAL <br />CONC - CONCRETE PB - PUSH BUTTON CODE PA 1.2 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA 1.3 PRODUCT APPROVAL <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE Q PORCHES AND BALCONIES to o LO <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 PA 1.4 PRODUCT APPROVAL > o 0 0 <br />CTR -CENTER REQD - REQUIRED PA 1.5 PRODUCT APPROVAL p M 6 <br />CJ - CONTROL JOINT R/A - RETURN AIR Q HANDRAILS - CHAP. 3 SH 1.0 HURRICANE SHUTTERS M 5 M <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.1 HURRICANE SHUTTERS to �% -0-0- - 2 o, <br />D A - DIAMETER RS -ROUGH SAWN ? o w u o <br />M <br />SC - SOLID CORE [:)GUARDRAILS - CHAP. 3 SH 1.2 HURRICANE SHUTTERS a <br />DIM - DIMENSION SCP -SCUPPER <br />DISCON -DISCONNECT Q SH 1.3 HURRICANE SHUTTERS pug o ¢ <br />SCRN -SCREEN STAIRS - CHAP. 3 SH 1.4 HURRICANE SHUTTERS <br />SH 1.5 HURRICANE SHUTTERS .N w D-' c <br />DW - DISHWASHER SIM - SIMILAR WP 1.0 WATERPROOFING DETAILS i 000 E � <br />DR -DOOR SHLVS -SHELVES Q CHIMNEY & FIREPLACE F0 y <br />DBL -DOUBLE S/R - SHELF & ROD CHAP. 10 WP 2.0 WATERPROOFING DETAILS � a _ <br />DWG -DRAWING SH -SINGLE HUNG WINDOW <br />WP 2.1 WATERPROOFING DETAILS <br />EA -EACH SGD - SLIDING GLASS DOOR Q EGRESS WINDOWS <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV -ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />EQUP - EQUIPMENT STD -STANDARD BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EXP JT - EXPANSION JOINT STL -STEEL GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />EXT - EXTERIOR STRUCT -STRUCTURAL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED <br />INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR - FLOOR TP - TOILET PAPER HOLDER <br />FLOUR -FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS Ld FR DR - FRENCH DOOR VAC -VACUUM W _1 x a z x <br />GALV - GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR U W ° ¢ o ¢ ¢ o ° o <br />( ) �. ocn0 WW9z oomZD 2 <br />GA -GAUGE VERT - VERTICAL TO BE TEMPERED GLASS. SECTION R308 Q Q U < o o - z x LL o z 2 o o � ¢ � <br />GB -GRAB BAR VIF -VERIFY IN FIELD _ <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR VTR -VENT THROUGH ROOF O O a> z Y o Z z LL o w o <br />GLS -GLASS V -VOLT to z ¢oW ���-�YOQQ ¢ <br />DIMENSIONING:IL <br />�¢<- wz� V�o. <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET O ¢ 0 0 0 ¢ Q w <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER A. DIMENSIONS INDICATED ARE TO:LL <br />HD - HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP -WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC -HANDICAP WDW -WINDOW FURRING\ <br />O <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD z 04 <br />INT - INTERIOR WD - WOOD W <br />LVL - LAMINATED VENEER LUMBER A.4. WINDOW OPENINGS: O <br />LT - LAUNDRY TUB A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />MAX - MAXIMUM A.5. DOOR OPENINGS: <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING 0 F. M O <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING Q (n co � <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED L <br />MC 11, <br />L - MEDICINE CABINET - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR W V <br />MIN - MINIMUM FRAME Q QLO <br />A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER 1-- 0 a (,ry <br />OF DOOR It a- V-- <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH Q >- Q00 <br />SURFACE TO FINISH SURFACE z U SYMBOLLEGEND: A.6.1.EXAMPLE: 3-0 CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER' <br />z3: <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND WuJ <br />= STAIR CALL OUT HEIGHT OF SHEET NUMBER PLUMB. J �O <br />STEP DOWN 1 C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: <br />INT ELEV NUMBER C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES IT <br />FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />O = SEESCHEDULE <br />FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />SCHEDULE <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />A9 ELEV NUMBER ARROW SHOWS UNLESS OTHERWISE NOTED <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE JUL Z 1 �023. <br />�q = OUT - SEE LENTEL EXTERIOR 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />SCHEDULE ELEVATION MARKER Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE <br />I <br />1 <---ELEV NUMBER 4SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LEDGER CALL OUT -SEE SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LEDGER SCHEDULE 4 A15 2 COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />3 ARROW SHOWS LOCATION OF CUT DRAWINGS. <br />DIRECTION OF VIEW 1 ' <br />Virtual Review Assist. Inc. rove <br />MULTI VIEW INTERIOR SECTION Plans Review completed and approved <br />ELEVATION MARKER MARKER fiance with the 2020 FBC 7th Edi ions <br />for camp �. <br />by Debra Anne l�tahr PX2300CD <br />0 0 0 0 0 0 <br />N N N N N N <br />O a O N N N I <br />O O � CD O i <br />Z <br />0 <br />N w <br />i d' L6 O i <br />CT >- <br />CO <br />Z ~ <br />¢Z <br />W <br />LE N O ��-+ w 000 <br />III owl <br />Z a�a <br />LENNAR TAMPA DIVISION L-n = =W <br />�M <br />Ln o' <br />0 <br />4600 W CYPRESS ST, SUITE 200 �" �Mcn <br />TAMPA FL 33607 NOTICE TO BUILDER &ALL SUBCONTRACTORS • • LO 2 p ZWO <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE z V aZ"" <br />BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING <br />813.574.5700 LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT z <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL O O (� J <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE W <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE Q <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION C S W <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THEuj <br />r <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE N <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK LAST PLOT DATE <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE May 8, 2023 <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND Z <br />2551 O <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />J COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.