Laserfiche WebLink
A/C <br />DIS( <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B <br />1 /411 = 1'-0" <br />ELEC <br />METER <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�— 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH--,— <br />SWITCH- <br />4 1/2" <br />DOORJAMB <br />DUPLEX <br />OUTLET M <br />TRIM <br />o <br />0 <br />BASE <br />4. <br />NOTE:. <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />k <br />r� <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />& 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />AT 12" - TOP PLUG IS HOT <br />1HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />-6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />--o DIMMER SWITCH AT 36" <br />—� PUSH-BUTTON DOORBELL <br />}- CLG MNT LT FIXTURE <br />{} CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />-(;)- <br />WALL MNT FIXTURE <br />NOTE: <br />C <br />OPALEX - <br />ALTERNATE <br />TUB/SHOWERND <br />CANS MAY BE <br />C <br />50W PAR30 NFL 6" WHITE BAFFLE <br />USEDIF <br />APPROVED BY <br />C <br />50W MR16 4" LOW VOLTAGE <br />OWNER <br />C <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />tl0 <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-ty} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />rS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= <br />SINGLE 24" FLUOR STRIP <br />=D-24= <br />DOUBLE 24" FLUOR STRIP <br />— U-36 = <br />UNDER CABINET 36" <br />— S-36 — <br />SINGLE 36" FLUOR STRIP <br />— D-36 — <br />DOUBLE 36" FLUOR STRIP <br />S-48 <br />SINGLE 48" FLUOR STRIP <br />— D-48 <br />DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />FF;F36:;;R 36" VANITY LIGHTING <br />4848" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MEMF MASTER STATION <br />_M&3 ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />ED A/C REGISTER <br />OT THERMOSTAT <br />EM SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />L <br />W 0 u <br />C) M d <br />M c 5 <br />N <br />} N <br />U -00 m a <br />.r M <br />� <br />E= ro <br />moo 2g <br />g ono a Q <br />s U�° <br />'^N, <br />W <br />w - <br />MO E�0 <br />L <br />0 <br />W WF- <br />�Lu LLI Uj Wow <br />~ <br />QX �gzx <br />Lu <br />�O��LL�o0UjU'X <br />�oz°QQa0 <br />Q QLL <br />x�0P ¢zz��z <br />awwOzox0omz <br />U <br />O <br />OwW <br />Z <br />L W�xx::) <br />Z <br />J�QoWQFnWWV0 <br />` <br />J <br />QO <br />W <br />Q <br />0Qz¢¢ <br />OX D ¢X <br />U_ Q o LL <br />O <br />Zw <br />Off_ <br />U =) ti <br />M O <br />Q w M11- <br />w U_ <br />ti <br />L0 <br />F— 0� 0- (M <br />a 0000 <br />zvla- <br />3: <br />LUz <br />W <br />J O <br />O <br />d' <br />ULAI <br />2 <br />123 <br />Vir <br />jai F <br />I <br />Am <br />� <br />As <br />I <br />iAt, <br />Inc. <br />Plans Rev <br />ew <br />comf <br />leteil <br />an <br />a <br />rove <br />for compGan <br />e w <br />th it <br />o 20 <br />20 F <br />3C% <br />h Edition <br />by <br />0 bra <br />ArInd <br />NlairIP113011 <br />t� <br />�— <br />O <br />r <br />O <br />N <br />CO <br />O <br />N <br />O <br />N <br />r <br />O <br />N <br />M <br />N <br />M <br />O <br />N <br />r <br />N <br />� <br />C), <br />C) <br />CDCDO <br />O <br />O <br />I <br />Z <br />0 <br />W <br />CV <br />LO <br />� <br />O <br />r <br />C)O <br />N <br />M <br />O <br />d' <br />CDO <br />u7 <br /><O <br />; <br />i <br />CO <br />zz <br />Q z <br />w <br />C)CO <br />4-1 <br />O <br />W <br />0 O _O <br />WU <br />U U <br />L <br />O <br />01-0 <br />Z <br />a iry <br />y / <br />W r <br />ft M <br />L <br />(� <br />mH <br />N <br />ZOM <br />■ ■ <br />w <br />L(� <br />O <br />zw0 <br />Q <br />U <br />gWLL <br />Z <br />Z <br />Wz <br />?� <br />o0 <br />U <br />W <br />z <br />a= <br />z <br />W <br />UJ <br />J <br />ti <br />� <br />o <br />LAST PLOT DATE <br />• <br />July 11, 2023 <br />Z <br />O <br />1ST FLOOR <br />ELECTRICAL PLAN B <br />