My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6489 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6489 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:58:26 PM
Creation date
2/19/2025 8:28:39 AM
Metadata
Fields
Template:
Building Plans
Street #
6489
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS (� <br />ABV - ABOVE MLDG - MOULDING VERSION DESCRIPTION OF CHANGES SHT NO: TITLE \ <br />AFF -ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING THE FOLLOWING TECHNICAL CODES SHALL APPLY: 1.0 PLAN REVISIONS CS COVER SHEET v ` M <br />AHU -AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN N <br />A/C -AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 TYPICAL TRUSS CONNECTOR REVISION A2 1ST FLOOR PLAN <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 = ,� f' i, <br />AT -ALUMINUM THRESHOLD OC - ON CENTER <br />3.0 ELEVATION A ENTRY PORCH ROOF UPDATE A3 2ND FLOOR PLAN <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 P.4 ROOF PLAN <br />4.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE A4.1 2ND FLOOR FRAMING & ROOF PLAN c <br />AVG -AVERAGE OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME °00 <br />A5 EXTERIOR ELEVATIONS a, <br />BFE -BASE FLOOD ELEVATION OPP -OPPOSITE 1.6 GALLONS 5.0 ADDING K, L, M ELEVATIONS � �' ° ° �,� <br />BM -BEAM OPT - OPTIONAL A6 1ST FLOOR ELECTRICAL PLAN ° <br />BLK -BLOCK OH - OVER HANG 6.0 ADDED SHEETS WP2.0 AND WP2.1 TO SHEET INDEX A6.1 2ND FLOOR ELECTRICAL PLAN p ¢ <br />2. WATER - FLOW RATE. <br />BLDG - BUILDING OH CABS- OVERHEAD CABS SNO STRUCTURAL NOTES € _ ?g; z <br />PUBLIC FACILITIES LAV 0.5 G.P.M. E <br />BRG - BEARING PTD -PAINTED BRD -BOARD PNT PAINT FINISH SN1 STRUCTURAL NOTES <br />PRIVATE FACILITIES LAV 2.2 G.P.M. 4 ucl <br />BTM -BOTTOM PED -PEDESTAL O <br />S3M FOUNDATION DETAILS _ <br />SHOWER HEADS 2.5 G.P.M. �t ,'.' <br />BUC -BUILT UP COLUMN PERF -PERFORATED S4 FRAME WALL DETAILS -� - - e p <br />S5 ROOF FRAMING DETAILS ' i x <br />CAB - CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES L! <br />CD - CONSTRUCTION DOCUMENTS PLYWD - PLYWOOD TO BE CPVC S6 WALL SECTION DETAILS <br />CLG - CEILING PKT - POC'<ET SS RETRO FIT DETAILS o t V w <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO ST STAIR DETAILS z <br />CEMT - CEMENTITIOUS PSF -POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S11 PRECAST DETAILS + ¢ <br />CL - CENTERLINE PSI - POUNDS PER SQUARE S12 PRECAST DETAILS <br />COL -COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA1.0 PRODUCT APPROVAL 1� Q <br />CONC -CONCRETE PB - PUSH BUTTON CODE PA1.1 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA1.2 PRODUCT APPROVAL N G% > o N o <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE [] PORCHES AND BALCONIES 0 L �o o q <br />PA1.3 PRODUCT APPROVAL <br />CONT - CONTINUOUS OR CONTINUES REINF REINFORCING CHAP. 3 C) M <br />PA1.4 PRODUCT APPROVAL i�Ln CO. <br />CTR -CENTER REQD - REQUIRED '� <br />PA1.5 PRODUCT APPROVAL <br />CJ - CONTROL JOINT R/A - RETURN AIR Q HANDRAILS - CHAP. 3 N -0-0- <br />DP M <br />- DEEP OR DEPTH RO - ROUGH OPENING <br />DTL - DETAIL RS -ROUGH SAWN SH 1.0 HURRICANE SHUTTERS u o 2 0 <br />SH 1.1 HURRICANE SHUTTERS rt� <br />Q GUARDRAILS - CHAP. 3 .� U 9 Q <br />DIA - DIAMETER SC - SOLID CORE SH 1.2 HURRICANE SHUTTERS _� <br />DIM - DIMENSION SCP -SCUPPER Q STAIRS - CHAP. 3 SH 1.3 HURRICANE SHUTTERS ,N V w QN <br />DISCON - DISCONNECT SCRN -SCREEN SH 1.4 HURRICANE SHUTTERS L 00 E <br />CO <br />DW - DISHWASHER SIM - SIMILAR SH 1.5 HURRICANE SHUTTERS a a <br />DR -DOOR SHLVS -SHELVES Q CHIMNEY & FIREPLACE - <br />DBL -DOUBLE S/R -SHELF &ROD CHAP. 10 WP1.0 WATERPROOFING DETAILS <br />WP2.0 WATERPROOFING DETAILS <br />DWG - DRAWING SH - SINGLE HUNG WINDOW WP2.1 WATERPROOFING DETAILS <br />EA -EACH SGD - SLIDING GLASS DOOR Q EGRESS WINDOWS <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV - ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS <br />EQUP - EQUIPMENT STD -STANDARD STATED BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS <br />EXP JT - EXPANSION JOINT STL -STEEL AND O.H. GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE <br />EXT - EXTERIOR STRUCT -STRUCTURAL ITEMS. THE MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED SITE INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR - FLOOR TP - TOILET PAPER HOLDER <br />FLOUR - FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6-8" UNLESS OTHERWISE NOTED ALL o w W o <br />FTG -FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS W F- < o � c z � <br />FIR DR -FRENCH DOOR VAC -VACUUM LLJ U LU �°2�¢o¢�¢Ct�oo_o <br />GALV - GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF Q Q U o J Z u 3 g Z 2 ° o z ¢ ¢ <br />(u)��0z0=00MzZ <br />GA -GAUGE VERT -VERTICAL FLR TO BE TEMPERED GLASS. (SECTION R308) W W CLW 7 W W W F5� � ¢ <br />GB -GRAB BAR VIF -VERIFY IN FIELD C� JQa>zYe0 zz_OW0oCL <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR VTR -VENT THROUGH ROOF DIMENSIONING: O0 Z ¢ o w W ~ I Y o 2 ¢ ¢ <br />GLS -GLASS V - VOLT o a o< Q W <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER A. DIMENSIONS INDICATED ARE TO: <br />HD -HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD 00 <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. �- N <br />HC - HANDICAP WDW - WINDOW FURRING\ <br />INSUL - INSULATION W/ - WiTH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD Z W <br />INT - INTERIOR WD - WOOD �_ <br />A.4. WINDOW OPENINGS: <br />LVL - LAMINATED VENEER LUMBER A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING (/) � <br />LGT - LIGHT LAUNDRY TUB A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING �_ (!� CO 0 <br />MAX - MAXIMUM A.5. DOOR OPENINGS: : M 0 <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING Q (n LO <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING J <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED U_ � <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR Q co Q � <br />MC - MEDICINE CABINET <br />FRAME �- l� 0- <br />MIN -MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER W a 2 T- <br />OF DOOR Q >- Q 0 <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH z 0 <br />SURFACE TO FINISH SURFACE Z <br />SYMBOL LEGEND. A.6.1. EXAMPLE: T-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER WB. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND J 0 <br />= STAIR CALL OUT HEIGHT OF SHEET NUMBER PLUMB. <br />- STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: <br />1 INT ELEV NUMBER C.l. CODE MINIMUM -MAXIMUM DIMENSIONS AND CLEARANCES <br />Iql- <br />FOOTING CALL OUT STEP DOWN ARROW SHOWS <br />SCHEDULE C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS <br />= SEE FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS > <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />ELEV NUMBER UNLESS OTHERWISE NOTED Virtual R vie qAs Assist, Ipnc. A9 ARROW SHOWS E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE Plans Review c mpl ted ad ved <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT pp <br />SOOT - SEE <br />SCHEDULE <br />ELEVAEXTERIOR TION MARKER 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED r compliance wi th 2[12 t xt Edi 'o <br />All SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE by Debra Anne Klah M 300 <br />1 < ELEV NUMBER SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LEDGER CALL OUT - SEE <br />SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LEDGER SCHEDULE 4 A15 2 COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />r ARROW SHOWS LOCATION OF CUT DRAWINGS. <br />3 DIRECTION OF VIEW IO <br />MULTI VIEW INTERIOR SECTION N N N N N N <br />ELEVATION MARKER MARKER O O CDO O O <br />LO N N N N N N <br />t� N N O <br />C)O o \ N N CD <br />CDa- CD CD C)i <br />Z <br />1 O <br />N� W 0 0 0 0 0 0 <br />'It <br />� N M 4 6 6 i <br />LO <br />Z00w/ ¢} <br />Z <br />� W <br />+C) oz <br />Z <br />WOo <br />L E N <br />red -0 ~ o � o <br />Z af�a <br />LENNAR TAMPA DIVISION N ODO <br />T SUITE 2 Z= 4600 W CYPRESS S SU 00 W N � Q�� <br />NOTICE TO BUILDER & ALL SUBCONTRACTORS 0O zoo <br />TAMPA, FL 33607 o z 0-z� <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE z <br />813.574.5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING � � z <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT U J <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL O <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE O <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE W <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE z z <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL C S Uj <br />CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION Uj o ti <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE N <br />2216 INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE LAST PLOT DATE <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK > May 9, 2023 <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE z -a <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND <br />APPROVAL BY THE DESIGN PROFESSIONAL. J COVER SHEET <br />_� iT I i 7 I I � <br />- - - -- - - - - i - -- - IT.- � �, is "I '- �TJF- �- i�,i��� a��,.iiLG.� �::�ir J <br />
The URL can be used to link to this page
Your browser does not support the video tag.