My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6489 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6489 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 4:58:26 PM
Creation date
2/19/2025 8:28:39 AM
Metadata
Fields
Template:
Building Plans
Street #
6489
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■. <br />■. <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP; <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCRE <br />WEEP SCREED -----------__ <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING ---- <br />COUNTER FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />PT 1X10 BLOCKING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />CEMENT MORTAR <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />3"=1'-0" <br />3"=1'-0" <br />WALL SHEATHING PER PLAN <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREE <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />PT 1X BLOCKIN <br />COUNTER FLASHING <br />00 <br />PAN FLASHING 6" MIN--____\ <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"---- <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS---__ <br />2X NAILER SECURELY <br />FASTENED TO DECK - <br />ROOF SHEATHING <br />NOTE: PER PLAN--- <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE <br />OUT OF CORROSION <br />-RESISTANT MATERIAL Aw <br />HEAD WALL <br />IGLE ROOF PER SPECS <br />ERLAYMENT <br />SHINGLE OVER <br />'EDGE <br />F SHEATHING <br />PAN <br />'EDGE <br />SUB FASCIA <br />- ADHERED WRB TO <br />IGLE OVER WRB ON <br />L BELOW <br />AINUM BRAKE METAL WRAP <br />T BACKER ROD <br />SEALANT <br />,CO'J' MOULDING <br />D OFF BRAKE METAL <br />AN <br />DCO ON FRAME - 7/8" <br />iAT SAND FINISH STUCCO <br />;ELF FURRING LATH ON 2- <br />:RS OF WATER RESISTIVE <br />BIER COMPLYING WITH <br />vl E2556, TYPE 1 (TYP) <br />L SHEATHING PER PLAN <br />FLASHING REQUIREMENTS <br />FIBER CEMENT SIDING <br />R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />PER ELEVATIONS <br />WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. <br />WALL SHEATHING PER PLAN___ - <br />WALL SHEATHING PER PLAN <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />SHINGLE WATER RESISTIVE <br />AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER <br />BARRIER OVER FLASHING <br />FIBER CEMENT SIDING <br />WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE <br />PER ELEVATIONS <br />EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO <br />STARTER STRIP <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER FLASHING <br />R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM <br />HOLD 1/4" AIR GAP <br />HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED <br />BETWEEN SIDING AND <br />STARTER STRIP <br />WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL <br />FLASHING <br />HOLD 1/4" AIR GAP <br />EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE <br />COUNTER FLASHING <br />BETWEEN SIDING AND <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE <br />FLASHING <br />JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED <br />CONT SELF ADHERED FLASHING TO --- <br />MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE <br />LAP FLASHING AND TURN 3" UP WALL <br />CONT SELF ADHERED FLASHING TO <br />BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT <br />LAP FLASHING AND TURN 3" UP WALL <br />OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />FLASHING <br />TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />PT 1X10 BLOCKING <br />PT 1X BLOCKING <br />APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />CONT SELF ADHERED FLASHING <br />COUNTER FLASHING <br />TURN 3" UP BLOCKING <br />R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />PAN FLASHING 6" MIN <br />INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />CEMENT MORTAR <br />SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />ROOF UNDERLAYMENT TO <br />PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />TILE ROOF PER SPECS <br />TURN UP BLOCKING MIN 6" <br />INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO <br />CONT SELF ADHERED FLASHINGPROVIDES <br />A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />TURN UP BLOCKING MIN 8" <br />TURN 3" UP BLOCKING <br />ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS, <br />ROOF SHEATHING <br />TILE ROOF PER SPECS <br />PER PLAN <br />EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />2X NAILER SECURELY <br />WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />FASTENED TO DECK <br />THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />OF SHEATHING <br />DESIGNED DRAINAGE SPACE. <br />PEER PLAN <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL HEAD WALL RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />W P 16 - ROOF TO WALL - BARREL TILE TO SIDING W P 17 ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />3��=1'-019 SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD <br />AND SIDES. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL, <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />ESE <br />ARE GENERIC AND MEANT TO SHOW <br />LS <br />W P 18 TH FLASHINGI AND WATERPROOFING METHODS TO BEUSED. GENERAL <br />JUL2 12023 <br />Virtual Review Assist. Inc. Plans Review completed and approved <br />for complianc�awith <br />Annethe <br />Klaho PX2300 Edition <br />by der <br />C_ <br />L <br />> <br />s <br />U <br />N <br />L <br />Q <br />O <br />C <br />CU <br />'s= <br />c <br />0O <br />O <br />CU <br />U_ <br />O <br />.� <br />O <br />cu <br />E <br />c <br />O <br />2 <br />Q <br />1--0.=U)Q <br />4O <br />Z <br />W <br />J <br />hI <br />C <br />a� <br />0 <br />SHEET N0, <br />WP 2A <br />
The URL can be used to link to this page
Your browser does not support the video tag.