6494 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6494 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 5:52:58 PM
Creation date
2/19/2025 8:29:06 AM
Metadata
Fields
Template:
Building Plans
Street #
6494
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
4151
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEV AT 18'-0" <br />SECOND FLOOR CEILING <br />PAINTED RAISED <br />STUCCO BAND <br />7/8" STUCCO <br />OVER PLYWOOD -- <br />CASING BEAD <br />W/ WEEPS OVER <br />FLASHING <br />ELEV AT 10'-0" <br />SECOND FLOOR FF - <br />ELEV AT 8'-8" <br />FIRST FLOOR CEILING <br />WEEP SCREED - <br />PAINTED RAISED <br />STUCCO BAND—� <br />5/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0" <br />FIRST FLOOR FF <br />FRONT ELEVATION B <br />3/ 16" = 1 '-0" <br />ELEV AT 18'-0" _ <br />SECOND FLOOR CEILING <br />ELEV AT 10'-0" <br />SECOND FLOOR FF - <br />ELEV AT 8'-8" <br />FIRST FLOOR CEILING <br />ELEV AT 0'-0" _ <br />FIRST FLOOR FF <br />REAR ELEVATION B <br />3/16" = 1'-0" <br />ROOF FINISH <br />ROOF FINISH <br />PER ELEVATION <br />PER ELEVATION <br />10" <br />PRAISED <br />12 <br />ROOF SHEATHING <br />12 <br />15 ROOF SHEATHING <br />4 <br />2" 8„ <br />STUCCO::::�, <br />BAND <br />5.9 <br />- MANUFACTURED <br />MANUFACTURED <br />"'Ij <br />ROOF TRUSS <br />ROOF TRUSS <br />21b. EPS <br />FOAM <br />° <br />®� <br />MTL DRIP EDGE <br />MTL DRIP EDGE <br />2X4 SUB -FASCIA <br />2P <br />N <br />ALUMINUM WRAP <br />ALUMINUM WRAP <br />_ _zo <br />ALUMINUM SOFFIT <br />1'-0" ALUMINUM SOFFIT <br />_ <br />CV <br />2 1/2" 1 1/2" <br />2 LB EPS FOAM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SMOOTH FINISH <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />ATTACHMENT DETAIL <br />ROOF O/H DETAIL <br />ROOF O/H DETAIL <br />BRACKET, DETAIL <br />CORBEL <br />DETAIL <br />5 <br />6 <br />7 <br />8 <br />1-011 <br />3 4 = <br />-0 <br />3/4 - <br />-0 <br />4 - <br />- <br />3/4111-1 <br />2'-8"PAINTED <br />co <br />RAISED <br />TRIM BAND <br />4 <br />6" PAINTED RAISED <br />TRIM BAND <br />4" <br />co <br />0 <br /><V <br />2" <br />SCORED LINES <br />4" <br />PAINTED RAISED <br />cm <br />TRIM BAND <br />L2 LB EPS FOAM <br />zo <br />SMOOTH FINISH <br />NOT USED <br />WINDOW�DETAIL <br />WINDOW TRIM <br />DETAIL <br />GARAGE <br />DOOR TRIM DETAIL <br />EIN.T.S. <br />83/4 <br />E1 <br />1 . <br />- <br />- <br />4 =1- <br />4' = <br />- <br />-•• <br />.rr��rrr�r��rrrr.�rrrrt�rrrrrrrv- � , �/�� <br />we <br />IsI? <br />M111M <br />�1 iii1 Sonoma <br />a _ MEN NEN <br />gill Mil■ <br />ram_ r <br />�M <br />WEEP SCREED <br />A5 <br />IN - <br />- <br />Mimi <br />ININ11 <br />- - <br />- - <br />imininimil <br />IN <br />4' OFF <br />RIDGE VENT <br />.ggiill,m����rr���m���m��i►,�.,.. <br />CASING BEAD <br />W/ WEEPS OVER <br />FLASHING <br />1'-0" <br />O.H. <br />-7/8" STUCCO <br />OVER FRAME <br />-DRIP "V" SCREED <br />8 <br />_ A5 <br />PAINTED RAISED <br />STUCCO BAND <br />-6" PAINTED RAISED <br />STUCCO BAND <br />-5/8" STUCCO <br />OVER CMU <br />-PAINTED METAL <br />GARAGE DOOR <br />ELEV AT 18'-0" <br />SECOND FLOOR FRAMING <br />ELEV AT 10'-0" _ <br />SECOND FLOOR FF <br />ELEV AT 8'-8" <br />FIRST FLOOR CEILING <br />ELEV AT 0'-0" _ <br />FIRST FLOOR FF <br />RIGHT ELEVATION B <br />3/16" = 1'-0" <br />ELEV AT 18'-0" _ <br />SECOND FLOOR CEILING <br />I z�F= <br />7/8" STUCCO 1 I g w <br />OVER FRAME o J Z� <br />L N J <br />C.J. SS C.J.I <br />0'-0" 14'-0" L <br />ELEV AT 10'-0" 12 <br />SECOND FLOOR FF 4 <br />CASING BEAD MID -WALL ELEV AT 8'-8" <br />W/ WEEPS WEEP FIRST FLOOR CEILING <br />OVER SCREED <br />FLASHING Oo <br />5/8" STUCCO e0 a0 00 <br />OVER CMU � Zo io <br />ELEV AT 0'-0" <br />qU FIRST FLOOR FF <br />LEFT ELEVATION B <br />3/16" = 1'-0" <br />12 <br />5 <br />I <br />I z= <br />I I <br />I NJ <br />I I <br />� <br />I <br />6'-4" 10'-0" <br />10'-8" <br />Li <br />DRIP "V" <br />SCREED <br />5/8" STUCCO <br />OVER CMU <br />4' OFF <br />RIDGE VENT 12 <br />5 <br />4' OFF <br />RIDGE VENT <br />HINGLE ROOF <br />II i 111�,� 1 t <br />5 <br />%_7/8" STUCCO I <br />OVER FRAME <br />I --,,,I <br />I I <br />L 10'-0" 6-4" <br />MID -WALL <br />WEEP <br />SCREED <br />I I <br />I I�w I _: I <br />7/8 STUCCO <br />o 1 OVER FRAME <br />I INS I —�I <br />C.J. C.J.I C.J. C.J. <br />3 -4 - 8'-8 - - - 8 -8 - - 8'-8" - - - 8'-8" <br />MID -WALL <br />WEEP %-5/8" STUCCO <br />SCREED OVER CMU <br />00 <br />HINGLE ROOF <br />CASING BEAD <br />W/ WEEPS <br />OVER <br />FLASHING <br />12 <br />..._ 14 <br />ti <br />12 <br />4 <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th <br />Edition by Debra Anne Klahr PX2300 <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />"v <br />k' <br />N <br />o <br />x <br />' ® <br />P\7 <br />re . <br />LO <br />°` <br />.` y' <br />00 <br />. <br />LO <br />IT <br />¢ <br />w <br />O <br />in <br />w <br />0 <br />z <br />Ln <br />a) L "'n- E <br />CY) N <br />N <br />N 7 <br />U 0� <br />❑ O� u 0 <br />�s °Cj �< <br />U <br />.N <br />w Qv <br />L "O E 1 <br />7W <br />V <br />oO 10) <br />�1 <br />W <br />W <br />❑w LU Wo1 <br />LU <br />1-Q 1 _ cr< z� <br />of Z) O <br />Q I¢- U <br />J�O�OfCOLLC) <br />0U)° <br />LD oF- Cx1roZoxo�mZ❑L�Z <br />¢ <br />�Q¢U <br />� <br />ZjW<W <br />O_ <br />W-�Og,a<0�zW <br />Z <br />0oCY <br />oz <br />HLL Ow WZ�¢ ox oQ <br />,La o <br />0 <br />0 <br />N <br />Z <br />O IW— <br />>_ (n O <br />C) M O <br />Q M L0 <br />LL <br />U) <br />� <br />— <br />Q W Q Ln <br />CL co <br />0o <br />Q >- Q <br />Z U H <br />W <br />W <br />J O <br />O <br />I <br />r <br />;I <br />� <br />I <br />N <br />IN <br />N <br />N <br />N <br />0 <br />� <br />CDM <br />N <br />N <br />N <br />N <br />N <br />O <br />N <br />r- <br />00 <br />o <br />o <br />z <br />O <br />wO <br />o <br />0 <br />0 <br />0 <br />> <br />CO V J <br />Z <br />z <br />W <br />¢ Z <br />w <br />O tl <br />W <br />O <br />C.)U <br />wzz <br />V U) <br />�-� <br />Oor> <br />LU 0 <br />Q <br />ZZ <br />0->R>a <br />r>Q <br />N <br />F-�W <br />N <br />Zoo <br />Wes_ <br />M <br />O <br />zof0 <br />r <br />V <br />LL <br />g Z LL <br />Z <br />�z <br />Q <br />F <br />-� <br />®U� <br />p <br />a. <br />W <br />Z <br />z <br />z <br />w <br />WLo <br />J <br />0 <br />LAST PLOT DATE <br />N <br />• <br />March 29, 2022 <br />z O <br />EXTERIOR <br />ELEVATIONS B <br />