ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/YOOA INDOOR <br />PANEL CENTER <br />n <br />200 amp <br />150 amp <br />UNDERGROUND DLiv1 <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER y <br />NEC 17, 250,94 <br />NEMA 1 <br />150 AMPI <br />200 AMP <br />to lights A outlets <br />to appliances and GFI <br />to WH <br />o Rarlpe <br />aHVAC <br />150=2/0 <br />200=4/0 In 2" Conduit <br />4 Bare Cu Ground •Y� AI <br />V <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />I. Electrical outlet heights as measured from cen finished floor to ter line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan Is Intended for bid purposes only. All work shall be done in strict accordance With the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where Installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range Is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />© <br />EXHAUST FAN <br />;�1 <br />1 I <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />)� <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)Qa 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />JQ <br />ELECTRIC PANEL <br />I <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />vII 2q <br />AV DTI, <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />LlGulvn I GtJ ncVGr I nlrLL <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />15'-0" <br />VERIF METER <br />LOCATION WITH <br />BUILD R WP +H.B. <br />I---1 & GFI I <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: Y4'=1'-0" <br />nl <br />C <br />O <br />o <br />>W <br />a� Co <br />C N <br />cc C.;o <br />m x <br />"'o- <br />N cc c= <br />' Q y N Y <br />fl+= N <br />o <br />.ca <br />a u'3 cc <br />is dLj <br />61 J� <br />> c o <br />a>t ea <br />c E <br />cc o <br />a u <br />4 <br />N <br />N <br />0 <br />N <br />I`-• <br />N <br />Ui <br />0 <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Bullding Code <br />- <br />Residentlal <br />7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering potions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />W <br />Q <br />$ <br />SLQ <br />0) <br />o) <br />iI <br />�Q w <br />� 04 0 J <br />M .444 M LLLL <br />J LL <br />In <br />LL LL - li <br />S2 <br />Z <br />CA tL <br />W <br />rR°f 0 <br />Z <br />co Z d <br />co <br />Z <br />CN <br />OU y <br />W <br />z <br />z <br />Z o <br />¢ v <br />(n <br />iX <br />cn <br />Z <br />U <br />O <br />- <br />c <br />toLn <br />w <br />¢ 00 <br />N <br />O <br />M <br />z <br />u <br />E <br />a <br />_® <br />a <br />w <br />O I_ <br />N <br />wok <br />[L Z <br />g� <br />Z <br />CD J <br />N� <br />�a <br />ra <br />fm <br />zo <br />U <br />W <br />gz <br />iR <br />$ <br />O <br />(6 <br />� <br />LO <br />L <br />9 <br />120 <br />Q <br />CL <br />CD <br />� <br />N <br />M <br />j <br />N <br />,N <br />T <br />m <br />LO <br />Q� <br />O <br />N <br />o <br />O <br />N <br />a) <br />ro <br />N <br />Z <br />C <br />ro <br />E d, <br />L' m <br />c <br />JOB <br />NO: <br />22-06456 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />