Laserfiche WebLink
4 <br />0 <br />7 <br />m <br />TYP @ 2 STORY <br />J <br />S6 <br />H.B. <br />(3) 2X4 #2 SPF W/ (3)16d 1 <br />TOENAILS @ BASE 8 <br />I <br />I <br />I <br />I I <br />GG <br />I <br />AC PAD AC PAD <br />UP <br />I <br />I <br />1 <br />1 I <br />I <br />33 <br />I <br />I <br />I <br />I I <br />-_ <br />16R <br />I <br />M <br />1 <br />1 21 <br />31 <br />1171 <br />I9 <br />0 <br />41 <br />51 61 <br />- <br />10 <br />00 <br />FLOOR G.T. <br />I <br />42" SLOPING <br />HALF <br />o 11 <br />M <br />O <br />rn <br />00 <br />FAMILY ROOM <br />WALL <br />(3) 2X4 #2 SPF <br />j 12 <br />- <br />8'-8" FLAT LG. <br />TOENAILS @ <br />I - <br />CARPET <br />BASE <br />FLEX <br />GG <br />8PW T <br />E ? <br />8'-8" FLAT CLG. <br />z <br />A <br />83 <br />� <br />CARPET <br />FL 0 G. <br />PLUMBING LINE <br />N <br />- <br />TO SECOND <br />(2) #5'S <br />2x6 WALL= <br />5-SH oo <br />FLOOR I <br />= <br />4 <br />" <br />-_--_-_ -- -- Jt <br />-----_ERAT <br />in <br />2068 B.F. <br />H7'-4' - -- <br />T <br />16'-4a" <br />3'-8" I 3'-8" 3'-6" <br />iD <br />6-0" _ _ -4lm2� _-i co <br />I <br />I <br />I <br />H <br />�, <br />� 1- <br />�I ` <br />J <br />S6 (3) 2X4 #2 SPF W/ <br />I i <br />� <br />FOYER-- -1_ 0 <br />I <br />I <br />I <br />o <br />0 <br />TYP @ 2 STORY (3)16d TOENAILS @ <br />�i <br />pa p� GO <br />8'-8" FLAT CLG. 30 <br />BASE <br />O <br />O SI <br />TILE -� R`4,, <br />I <br />(2) #5'S <br />U_ <br />U_ Lt <br />4 <br />- -1-- <br />(3) 2X4 #2 SPF W/ <br />q <br />(3) 2X4 #2 SPF W/ <br />(3)16d TOENAILS <br />N <br />N (3)16d TOENAILS <br />S3 @ BASELO <br />N <br />o----- <br />@BASE <br />-- - - - <br />q <br />2'-6" BUILDER TO PROVIDE <br />APPLIANCE PROTECTION <br />j S3 I I <br />`° Q 8 DINING ROOM <br />WHEN REQUIRED PER FBC <br />ENTRY <br />PATIO O� 8'-8" FLAT CLG. <br />1 I I <br />8'-8" FLAT CLG. <br />T <br />CARPET <br />2 CAR GARAGE <br />I I <br />8'-8" FLAT CLG. AFF <br />I I I <br />I I L_ <br />4'-0" 6'-2" 6'-6" <br />4'-10" <br />20'-6" <br />I I I c <br />,�_ I---__--___J <br />i--------------I <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />'- <br />I I I= I <br />I I I I <br />(c <br />o <br />N <br />3, 76 JB 3 <br />I_J <br />i <br />O <br />-- <br />CC <br />I I Iul <br />L <br />33 <br />I 1 1 0 1 <br />- -- �-ITCHEN N � <br />m <br />r 10 <br />-i <br />J. 8-8 FLAT CLG. I >; <br />- H1 -,, <br />I I I I� <br />TIE ito <br />2868 <br />I I I Iw <br />Iz <br />II <br />- REF. <br />�2668 B.F. <br />2x6 WALL <br />1II K <br />II <br />N <br />OPT. <br />PANTRY <br />_ <br />VERIFY LOCATION <br />L---____--__EQ <br />-__- <br />16" DEEP <br />S3 ELECTRICAL PANEL <br />I <br />, <br />5 -SH <br />_ <br />N <br />J <br />S6 TYP @ 2 STORY <br />VERIFY METER LOCATION <br />WITH BUILDER <br />N <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX254 <br />S.H. <br />13 <br />20 X 381 <br />18 4 X 37 J <br />S.H. <br />14 <br />20 X 501 <br />18 } X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 } X 62 1 <br />S.H. <br />16 <br />20X72 <br />18}X71J <br />S.H. <br />11­12 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />11­13 <br />271/4X38J <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 1 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 1 X 63 <br />26 X 62 1/2 <br />S.H. <br />11-16 <br />27}X72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 } X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 } X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 } X 50 <br />S.H. <br />25 <br />37JX63 <br />36JX621/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 J X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54X26 <br />52+JX25} <br />S.H. <br />33 <br />54 X 38 J <br />52 J X 37 J <br />S.H. <br />34 <br />54 X 501 <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 } <br />S.H. <br />36 <br />54 X 72 <br />52 J X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />[DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FIRST FLOOR PLAN - ELEV-B1 <br />SCALE: /4'=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd, or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3.Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />AC� <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -37.0 <br />DE <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />aG <br />SEE SN SHEET HO SEE SN SHEET <br />6 <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WALL LEGEND <br />111111111111111 <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 11131" <br />FIRST FLOOR LIVING 1093 <br />AREA <br />SECOND FLOOR LIVING 1489 <br />AREA <br />LIVING TOTAL 2582 <br />GARAGE 427 <br />FRONT ENTRY 35 <br />TOTAL AREA 3044 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />(GARAGE / LIVING) <br />JR-11/R-13 KRAFT FACED <br />N <br />0 <br />N <br />c� <br />C c <br />0 <br />F- -o <br />W <br />C ro C.D N <br />ui P ro <br />w <br />Q �•' tV Y <br />Rv <br />� yea <br />.3 <br />ro <br />iv`ai Oia <br />d c o <br />a Rs <br />ro E <br />o <br />o.. u <br />.o <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and spedflcations contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal Is only for <br />the structural engineering potions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />N <br />W <br />h <br />m S <br />N O LL <br />v <br />I <br />aLLLL a <br />a <br />0 <br />Z cc <br />L A Z <br />5^ti 0 <br />N <br />0 <br />W °f m Lu <br />Z MzQ� <br />N <br />IL <br />OU <br />Z <br />W <br />z <br />z � <br />z � <br />Q � <br />U1o <br />Tl (n LL <br />LU <br />'U <br />0 w <br />c_ d <br />_ <br />C)_ <br />Q <br />_I <br />E <br />E <br />a <br />�R <br />go <br />E'. U <br />a <br />o <br />w� <br />UO <br />z&� <br />off <br />wg <br />�o <br />m� <br />°a <br />C <br />= <br />Y <br />QLL <br />z <br />C <br />z <br />g <br />W1 <br />U <br />�- <br />- <br />mi <br />" <br />A <br />Oki <br />O <br />J <br />1211 <br />LO <br />cc <br />�.. <br />Fes- <br />C'7 <br />:3 04 <br />N <br />Y <br />T <br />m <br />m <br />LO <br />C) <br />^I <br />(N <br />C) <br />Ln <br />N <br />Q r <br />ui <br />E <br />N <br />' M to <br />c <br />z <br />C <br />E <br />L <br />E <br />C <br />a <br />0 _J <br />JOB <br />NO: 22-06457 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.0 <br />