Laserfiche WebLink
1 11 1 1 - - I' — -_ - 1 1 . f_ 1 1 PI .- I 1- - - - <br />APPLICABLE CODES <br />BUILDING CODE: FLORIDA BUILDING CODE 2017 (FBC 2017) - SIXTH EDITION <br />ACCESSIBILITY: FBC 2017, ACCESSIBILITY <br />MECHANICAL CODE: FBC 2017, MECHANICAL <br />ELECTRICAL CODE: FBC 2017 - CHAPTER27; NFPA 70 (N.E.C.) <br />PLUMBING CODE: FBC 2017, PLUMBING <br />GAS FUEL CODE: FBC 2017, GAS FUEL <br />ENERGY CONSERVATION: FBC 2017, ENERGY <br />FIRE SAFETY CODE: FLORIDA FIRE PREVENTION CODE - FIFTH EDITION <br />(BASED ON NFPA1; NFPA 101 & LIFE SAFETY CODE, 2012 EDITION) <br />BUILDING CATEGORIZATION & PHYSICAL PROPERTIES <br />OCCUPANCY CLASSIFICATION <br />FLORIDA BUILDING CODE <br />FLORIDA FIRE PREVENTION <br />CODE <br />CHAPTER 3, SECTION 302 <br />NFPA 101, CHAPTER 6 <br />BUSINESS <br />BUSINESS <br />CONSTRUCTION TYPE <br />FLORIDA BUILDING COQE <br />FLORIDA FIRE <br />PREVENTION CODE <br />CHAPTER 6 <br />NFPA 101-8.2.1.2 <br />II-B <br />PER FBC: II-B <br />WIND SPEED DESIGN CRITERION <br />*WIND SPEED CLASSIFICATION EQUAL <br />TO OR EXCEEDING 140 MPH QUALIFIES <br />PROJECT FOR WIND BORNE DEBRIS <br />REGION <br />FLORIDA BUILDING CODE <br />FLORIDA FIRE <br />PREVENTION CODE <br />PROVIDED <br />CHAPTER 16, SECTION 1609 <br />FIGURE 1069.3(1) <br />VULK = 140 MPH <br />(RISK CATEGORY II) <br />N/A <br />REFER TO <br />"PA" DWGS <br />BUILDING PHYSICAL PROPERTIES <br />FLORIDA BUILDING CODE <br />FLORIDA FIRE <br />PREVENTION CODE <br />PROVIDED <br />SECTION 501 <br />ALLOWABLE HEIGHT <br />55, (TABLE 504.3) <br />N/A <br />19'-7" <br />ALLOWABLE NUMBER OF STORIES <br />(TABLE 504.4) <br />N/A <br />1 <br />ALLOWABLE AREA PER FLOOR <br />23,000 <br />(TABLE 506.2) <br />N/A <br />460 <br />7, T. <br />SPRINKLER SYSTEM <br />NON -SPRINKLER <br />N/A <br />N/A <br />FIRE RATING REQUIREMENTS <br />BUILDING COMPONENTS <br />FLORIDA BUILDING CODE <br />NFPA 101 - <br />LIFE SAFETY CODE <br />NFPA 220 <br />PROVIDED <br />TABLES 508.4, 601, 602, & 1020.1 <br />7.1.3.1 & <br />6.1.14.4.1 <br />TABLE 4.1.1 <br />STRUCTURAL FRAME <br />0 <br />0 <br />0 <br />BEARING WALLS - EXTERIOR <br />0 <br />0 <br />0 <br />BEARING WALLS - INTERIOR <br />0 <br />0 <br />0 <br />NON -BEARING WALLS - EXTERIOR <br />0 <br />0 <br />0 <br />NON -BEARING WALLS - INTERIOR <br />0 <br />0 <br />0 <br />FLOOR CONSTRUCTION <br />0 <br />0 <br />0 <br />ROOF CONSTRUCTION <br />0 <br />0 <br />0 <br />OCCUPANCY SEPARATION <br />N/A <br />N/A <br />N/A <br />CORRIDORS <br />0 <br />0 <br />PER 12.3.6 (2) <br />0 <br />FIRE EXTINGUISHER REQUIREMENTS <br />FIRE EXTINGUISHER COMPONENT <br />FLORIDA BUILDING CODE <br />FLORIDA FIRE PREVENTION CODE <br />NFPA 10, TABLE 6.2.1.1 <br />ORDINARY HAZARD OCCUPANCY <br />MAXIMUM FLOOR AREA PER UNIT OF A <br />N/A <br />1,500 SQ FT <br />MAXIMUM FLOOR AREA PER <br />EXTINGUISHER <br />N/A <br />11,250 SQ FT <br />MAXIMUM TRAVEL DISTANCE <br />N/A <br />75 FT <br />EXITING REQUIREMENTS <br />EXITING COMPONENT <br />FLORIDA BUILDING CODE <br />NFPA 101 - LIFE SAFETY CODE <br />PROVIDED <br />COMMON PATH OF TRAVEL TO AN EXIT <br />100, <br />[1006.2.11 <br />75' <br />[TABLE A.7.6] <br />52' <br />MAXIMUM DEAD END CORRIDOR <br />[1020.4 (2)] <br />[TABLE A.7.61 <br />19'-3" <br />MAXIMUM TRAVEL DISTANCE TO EXIT <br />200 FT <br />[TABLE 1017.21 <br />200' <br />[TABLE A.7.61 <br />52' <br />MINIMUM CORRIDOR WIDTH <br />[1020.21 <br />36" <br />[7.3.4] <br />48" <br />MIN. <br />MINIMUM CLEAR OPNG OF EXIT DOORS <br />[1010.1.1] <br />[7.2.1.2.1] <br />34" <br />MINIMUM STAIR WIDTH <br />N/A <br />N/A <br />N/A <br />OCCUPANT LOAD & EGRESS WIDTH CALCULATIONS FLORIDA BUILDING CODE <br />OCCUPANCY <br />AREA <br />(SQ FT) <br />TABLE 1004.1.2 <br />OccuEGRESSREQ <br />PANT <br />PANT <br />LOAD <br />SECTION 1005 <br />EGRESS <br />WIDTH <br />PRO- <br />VIDED <br />OCCUPANT USE <br />AREA/ <br />OCCU- <br />PANT <br />(SQ FT) <br />WIDTH / <br />PERSON <br />SERVED <br />EGRESS <br />EGRESS <br />WIDTH <br />BUSINESS <br />1,060 <br />SEE PLAN <br />100 <br />13 <br />0.2 <br />3" <br />- <br />EXERCISE <br />1,382 <br />SEE PLAN <br />50 <br />28 <br />0.2 <br />6" <br />- <br />LOCKER <br />653 <br />SEE PLAN <br />653 <br />14 <br />0.2 <br />3" <br />- <br />ASSEMBLY, UNCONC - T & C <br />1,417 <br />SEE PLAN <br />15 <br />99 <br />0.2 <br />20" <br />- <br />DAYCARE <br />377 <br />SEE PLAN <br />377 <br />11 <br />0.2 <br />3" <br />- <br />MERCANTILE <br />305 <br />SEE PLAN <br />305 <br />6 <br />0.2 <br />2" <br />- <br />KITCHEN, COMMERCIAL <br />511 <br />SEE PLAN <br />511 <br />3 <br />0.2 <br />1" <br />ACCESS. STOR, MECH & ELEC <br />267 <br />SEE PLAN <br />300 <br />6 <br />0.2 <br />2" <br />- <br />TOTAL <br />5,972 <br />SEE PLAN <br />180 <br />40" <br />>40" <br />PLUMBING FIXTURE CALCULATION <br />AREA <br />(SQ FT) <br />AREA/OCCUPANT <br />(SQ FT) <br />OCCUPANTS <br />BUILDING <br />SEE OCCUPANT <br />LOAD CALC TABLE <br />180 <br />ASSUME: 90 OCCUPANTS MALE <br />90 OCCUPANTS FEMALE <br />WATER CLOSETS <br />LAVATORIES <br />DRINKING FOUNTAINS <br />SERVICE SINKS <br />MALE/FEMALE <br />1/25 FIRST 50, 1/50 REMAINDER 50 <br />1/40 FIRST 80, 1/80 REMAINDER 80 <br />1/100 <br />REQ'D:3 <br />REQ'D:3 <br />REQUIRED:4 <br />REQUIRED:2 <br />REQUIRED:1 <br />PROPOSED: <br />1 <br />PROPOSED: <br />3 <br />PROPOSED: <br />6 <br />PROPOSED: <br />2 <br />PROPOSED: <br />1 <br />URINALS: 2 <br />PROPOSED UNISEX <br />X I <br />PROPOSED UNISEX <br />X <br />WELLNESS/FITNESS <br />CENTER & <br />TRAINING <br />87" 19/435 113 <br />O.L. = 28 <br />(EXERCISE) <br />WOMEN'S MEN'S KID'S CLUB <br />RESTROOM RESTROOM RESTROOM <br />114 115 L J 105 <br />EGRESS ARROW <br />OCCUPANT <br />CAPACITY <br />gg/1- 7� � <br />ACTUAL OCCUPANT LOAD <br />CLEAR WIDTH <br />FEC <br />FIRE EXTINGUISHER CABINET <br />WITH A 2A:10B:C FIRE EXTINGUISHER <br />EACH <br />FIRE EXTINGUISHER ON BRACKET WHERE <br />INDICATED ON PLAN <br />EXIT SIGN L <br />GRAPHIC ILLUSTRATION OF TRAVEL DISTANCE TO <br />EXIT FROM REMOTE POINT <br />LIFE SAFETY LEGEND O <br />1/8" = 1'-0" <br />i <br />I <br />O.L.=1 <br />(ACC. STOR.) <br />- O.L.=1 <br />(ACC. STOR.) <br />FIRST FLOOR LIFE SAFETY PLAN O <br />1/8" = r'-o" 1 <br />N <br />K <br />d <br />Y <br />W <br />F <br />Z <br />O� <br />N M E <br />C <br />M <br />E O <br />o U <br />tQ�M pg$ <br />V Co <br />Z <br />w co <br />11 01 10J <br />lV��{1�1Q�f1� <br />O M ^ <br />C <br />C <br />ole <br />G <br />Q a J p p M <br />a Y LL "'ao <br />C <br />Z C <br />r <br />Wid <br />.a ` <br />►-W <br />o U <br />a� <br />V <br />x <br />fn <br />A <br />W <br />M <br />W <br />� <br />x <br />cc <br />W <br />V <br />IW6 <br />Z <br />W <br />z <br />J <br />W <br />_ <br />('D <br />a <br />�- <br />W <br />O <br />J <br />= <br />co <br />W <br />LL <br />� <br />W <br />W <br />~ <br />Z <br />J <br />J <br />N <br />0 <br />W <br />ZU <br />O <br />Q <br />\ <br />Iz <br />W <br />N <br />T <br />U <br />� <br />r� <br />V <br />THIS DESIGN AND DRAWING IS THE <br />SOLE PROPERTY OF <br />FLEISCHMANGARCIA. NO PART OF THIS <br />WORK MAY BE REPRODUCED WITHOUT <br />PRIOR WRITTEN PERMISSION FROM <br />FLEISCHMANGARCIA. <br />ERTIFY=RELEVANT <br />EDGE WITH <br />PERMIT <br />DOCUMENTS <br />/--"\ 101 A Q.- / <br />SOt--crFLEISCHMAN, JR. <br />AR0005569 <br />6-21-19 <br />FGA PROJECT NUMBER <br />19020 <br />ISSUE <br />DATE <br />6/21 /2019 <br />REVISIONS <br />F <br />DATE NOTES <br />i <br />SHEET NAME <br />LIFE SAFETY FLOOR <br />PLAN & BUILDING <br />CODE DATA <br />SHEET NUMBER <br />A0.2 <br />