My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6606 Gall Blvd (5)
Zephyrhills
>
Building Department
>
Building Plans
>
6606 Gall Blvd (5)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:35:41 PM
Creation date
2/19/2025 8:32:13 AM
Metadata
Fields
Template:
Building Plans
Street #
6606
Location
Gall Blvd
Contractor
Joseph L Oliveri
Building Plans - Permit #
4037
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
22'-8" AFF. <br />TOP OF EXISTING <br />PARAPET <br />(LEFT/RIGHT OF <br />CENTER PORTION) <br />10'-6" AFF. <br />........... <br />BOTT. OF <br />CANOPY <br />OIL 0'-0" FF.E. <br />TOP OF SLAB <br />DI UJEST EXTERIOR ELEVATION <br />SCALE: 3/16" = I'-0" <br />EXISTING SIDING OR NEW <br />HARDIPLANK / NICHIHA <br />SIDING OVER "TYVEK" <br />BUILDING WRAP <br />NEW GRAY ALUMINUM <br />FLASHING AS REQUIRED <br />n <br />N <br />NEW GRAY ALUMINUM <br />FLASHING AS REQUIRED <br />LIGHT FIXTURE - <br />SEE ELECTRICAL <br />EXISTING SIDING OR NEW <br />HARDIPLANK / NICHIHA <br />SIDING OVER "TYVEK" <br />BUILDING WRAP <br />------------------------------------------------------------------------------------------------------------------------ - -------------------------------- <br />------------------------------------------------------------------------------------------- <br />EXISTING SHEATHING OR <br />NEW 1/2" CDX PLYWOOD <br />SHEATHING <br />I PI I <br />NEW ix HARDITRIM STANDOUT <br />- MAKE 2" WIDER OVERALL <br />THAN WIDTH OF MOUNTING <br />BRACKET COVER PLATE <br />KEYED NOTES <br />Ol <br />EXISTING ROOF SYSTEM <br />O2 <br />EXISTING FASCIA SYSTEM <br />0 <br />EXISTING SIDING / PANELING <br />OEXISTING <br />BRICK VENEER SYSTEM <br />OEXISTING <br />LIGHT FIXTURE <br />O6 <br />EXISTING CONCRETE WALK <br />OEXISTING <br />ROOF ACCESS LADDER <br />OS <br />EXISTING GUTTER / DOWNSPOUT SYSTEM - PAINT BLACK <br />O9 <br />EXISTING ELECTRICAL METER / SERVICE <br />10 <br />EXISTING MECHANICAL UNIT / EQUIPMENT / VENT <br />11 <br />EXISTING DOOR SYSTEM <br />12 <br />NEW CONCRETE BLOCK INFILL. ALIGN TO MATCH EXISTING <br />13 <br />NEW WINDOW / DOOR SYSTEM - SEE FLOOR PLANS <br />14 <br />EXISTING DRIVE-THRU CANOPY - PAINT BLACK <br />15 <br />NEW ALUMINUM CANOPY SYSTEM - SEE DETAIL 5/A5 <br />ib <br />NEW STANDING SEAM SLOPED CANOPY SYSTEM - SEE DETAIL A/A5a <br />17 <br />NEW HARDIPLANK SIDING OVER "TYVEK" BUILDING WRAP OVER <br />NEW EXTERIOR GRADE PLYWOOD SHEATHING <br />IV-4" AFF. rL <br />18 <br />NEW SIGNAGE - HAND PAINTED OR LASER CUT, POWDER COATED, <br />EXISTING TRUSS <br />BLACK METAL SIGN <br />BEARING <br />19 <br />NEW LIGHT FIXTURE - SEE DETAIL A/A4a <br />V -4" AFF. <br />TRUSS <br />20 <br />NEW PARAPET AND TRIM WITH METAL COPING - SEE WALL SECTIONS <br />BEARING <br />21 <br />NEW NICHIHA SIDING OVER "TYVEK" BUILDING WRAP OVER 1/2" <br />EXTERIOR GRADE PLYWOOD SHEATHING - SEE WALL SECTIONS <br />22 <br />KNOX BOX MOUNTED AT 60" <br />23 <br />APPROVED "LIGHT FRAME ROOF" SYMBOL PER FL STATUTE <br />633.021. MOUNT SYMBOL ON A 12" x 12" WHITE HARD PANEL. <br />24 <br />SYMBOL IS RED. MOUNT TOP OF SYMBOL AT 60" A.F.F. <br />NEW ALUM. GUTTER / DOWNSPOUT SYSTEM - SEE ROOF PLAN <br />25 <br />EXISTING GAS SERVICE <br />TOP OF SLF L AB <br />TOP S <br />8EXISTING <br />PARAPET - COPING TO BE PAINTED BLACK <br />0 <br />EXISTING CORRUGATED METAL SYSTEM <br />28 <br />NEW 5' TALL ALUMINUM TUBE / WIRE MESH PAIR OF GATES <br />29 <br />NEW SMOKER <br />QNEW <br />METAL PANEL ROOFING OVER PEEL AND STICK WATERPROOF <br />MEMBRANE OVER NEW PLYWOOD SHEATHING - MATCH EXISTING <br />31 <br />NEW 24 GAUGE CORRUGATED PANELS (2-1/2" RIB PATTERN) WITH <br />GALVANIZED FINISH OVER "TYVEK" BUILDING WRAP OVER EXISTING <br />EXTERIOR GRADE PLYWOOD SHEATHING <br />32 <br />EXISTING DOWNSPOUT AND OVERFLOW SCUPPER - PAINTED BLACK <br />33 <br />NEW STOREFRONT WINDOW IN NEW MASONRY OPENING <br />34 <br />NEW ROOF STRUCTURE OVER ADDITION - SEE WALL SECTIONS <br />35 <br />NEW FASCIA SYSTEM TO MATCH EXISTING <br />36 <br />NEW CONCRETE WALK <br />0 <br />HAND PAINTED ARROW GRAPHICS <br />38 <br />EXISTING DRIVE-THRU WINDOW SYSTEM <br />39 <br />OUTLINE OF EXISTING VINYL FENCE AND GATE <br />ONEW <br />CONDUCTOR HEAD, DOWNSPOUT SYSTEM < OVERFLOW <br />SCUPPER - SEE ROOF PLAN <br />EXTERIOR FINISH SCHEDULE <br />NI 1 <br />NEW NICHIHA SIDING "VINTAGEWOOD AWP3030 CEDAR" <br />P1 <br />EXTERIOR PAINT COLOR TO BE SHERWIN WILLIAMS <br />Q <br />SW1011 "GRAY SCREEN" <br />EXTERIOR PAINT COLOR TO BE SHERWIN WILLIAMS <br />S16258 "BLACK" - TO MATCH PRE -FINISHED FASCIA <br />COLOR SELECTION <br />P3 <br />ARROW COLOR TO BE WHITE <br />BRI <br />BRICK AND MORTAR COLOR TO MATCH EXISTING <br />AW <br />AWNINGS COLOR TO BE BLACK <br />GD <br />GUTTERS AND DOWNSPOUTS COLOR TO BE BLACK <br />MR <br />METAL PANEL ROOFING - VERIFY COLOR SELECTION <br />WITH OWNER / ARCHITECT - MATCH EXISTING <br />Cl <br />ALUMINUM COPING TO BE BLACK <br />a <br />CORRUGATED METAL - GALVANIZED <br />AZ <br />CLEAR ANODIZED ALUMINUM <br />TYPICAL SIC--ITIXTUi�E 1"IOUNTIN DETAIL <br />v <br />P1 <br />v <br />1. <br />PAINTING CONTRACTOR TO INSPECT ALL EXISTING CONDITIONS AND <br />rQ <br />O <br />1-IGti� <br />15 <br />35 <br />P2 <br />SEAL / CAULK AS REQUIRED IN ORDER TO ENSURE A WATERTIGHT <br />SCALE: 1 1/2" I'-0" <br />PI <br />CONDITION <br />P2 <br />3 <br />11'-4" AFF. <br />10'-fo" AFF. <br />AW <br />AW <br />_.. <br />EXISTING TRUSS <br />2. <br />ALL EXISTING SIDING, SURFACES AND TRIM TO BE REPAINTED PER <br />BOTT. OF <br />2 BEARING <br />EXTERIOR FINISH SCHEDULE <br />CANOPY <br />3. <br />ALL NEW SIDING AND TRIM TO BE PAINTED PER EXTERIOR FINISH <br />24 <br />g� <br />5 <br />SCHEDULE <br />— - <br />r/ <br />/ <br />/r <br />4. <br />ALL EXISTING BRICK TO BE PRESSURE CLEANED AS REQUIRED <br />GD <br />8 <br />5. <br />ALL EXISTING AND NEW BRICK TO RECEIVE ENVIROSEAL SEALER <br />6. <br />ALL EXISTING FASCIA AND SOFFIT MATERIAL TO BE INSPECTED FOR <br />19 <br />\ <br />r, <br />it <br />P3 <br />GOOD CONDITION. PATCH, REPAIR OR REPLACE A$ NECESSARY. <br />_ <br />• <br />, <br />1. <br />ALL EXTERIOR FINISHES AND PAINT COLOR SELECTIONS TO BE <br />21 <br />r <br />3 <br />VERIFIED WITH OWNER BEFORE ORDERING. <br />S. <br />ALL EXTERIOR LIGHTS AND DRIP EDGES TO BE BLACK VERIFY WITH <br />P1 <br />%OWNER <br />0'-0" FF.E. <br />0'-0" FF.E. <br />S. <br />FINISH PRODUCT SUPPLIED BY "AMERICAN PRODUCTS, INC." - REFER <br />TOP OF SLAB <br />- <br />- - - - <br />- <br />- - - <br />- - - - <br />- - <br />- - - <br />- - - - <br />- - <br />- - - <br />- <br />- <br />- <br />- <br />- - <br />- <br />" " TOP OF SLAB <br />TO SONNY'S PRODUCT REFERENCE GUIDE - CONTACT MICHAEL <br />CALDERONE (813) 925-0144 MCALDERONEOAMERICANPROD.COM <br />-----------------------------------------------------------------------77 <br />-------------------------------- <br />A NOT USED IG)l SOUTH EXTERIOR ELEVATION <br />SCALE: x" = 1'-0" SCALE: 3/16" = 1'-0" <br />KEY PLAN <br />REVISIONS <br />BY <br />W CON <br />to <br />� <br />Q <br />o .a o <br />,u v t� U <br />U <br />/ N <br />0 <br />Lo <br />Q m — o <br />3 <br />0 N <br />o <br />m <br />N <br />MINI <br />.. <br />co <br />o <br />Lu <br />. R <br />�r <br />7� <br />C <br />O -o _ <br />o 0 <br />o <br />Y <br />to U <br />O <br />V) <br />O <br />0 <br />CY <br />O <br />�- <br />N <br />C m -* <br />Lo <br />0 O <br />I M <br />m M} <br />� C <br />v <br />m m L` <br />06 <br />^ y <br />V <br />O cD >- <br />O t <br />to a- <br />Z <br />0 N <br />0 <br />m <br />V) <br />Date: 05. 17. 21 <br />Scale: AS NOTED <br />Project Mgr: DG <br />Drawn: DD <br />Job: 21-018 <br />Sheet <br />A4a <br />
The URL can be used to link to this page
Your browser does not support the video tag.