My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6606 Gall Blvd (5)
Zephyrhills
>
Building Department
>
Building Plans
>
6606 Gall Blvd (5)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:35:41 PM
Creation date
2/19/2025 8:32:13 AM
Metadata
Fields
Template:
Building Plans
Street #
6606
Location
Gall Blvd
Contractor
Joseph L Oliveri
Building Plans - Permit #
4037
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
®EXTEND NEW 1"CW FROM EXISTING BUILDING MAIN COLD <br />WATER LINE. <br />® EXTEND NEW 3i4"140°HW FROM EXISTING BUILDING MAIN 140' <br />HOT WATER LINE. <br />® EXISTING 2" GAS MAIN. <br />®CONNECT NEW 2" GAS LINE TO EXISTING AT PREVIOUS <br />LOCATION. PROVIDE GAS COCK AND QUICK DISCONNECT FOR <br />EACH EQUIPMENT CONNECTION. EXTEND PIPING AT WALL TO <br />24" A.FF. <br />®ROUTE GAS DOWN, EXPOSED ON WALL WITH SHUT-OFF VALVE <br />MOUNTED ON WALL. EXTEND PIPING AT WALL TO 24" A.FF. <br />PROVIDE PLUG VALVE, REDUCER, AND AGA RATED FLEX <br />SUPPLY AT CONNECTIONS. <br />© CONNECT TO EXISTING FILTERED WATER LINE ABOVE CEILING <br />AND PROVIDE 1/4"FW DROP TO EACH ITEM %2. <br />® CONNECT TO EXISTING FILTERED WATER LINE ABOVE CEILING <br />AND PROVIDE 11/2"FW DROP TO ITEM 059. <br />® CONNECT NEW 1i2"H4CW TO NEW PLUMBING FIXTURE FROM <br />EXISTING HOT AND COLD WATER MAINS. <br />OPROVIDE HW HOSE BIBS MOUNTED ABOVE PASS THRU <br />OPENING. <br />KEYED NOTES: Q <br />a <br />FIXTURES <br />CAPACITY <br />MBH EACH <br />ANTI <br />EACH <br />TOTAL CAP <br />MBH ALL <br />FRYER 034 <br />380 <br />1 <br />360 <br />GRIDDLE 035 <br />54 <br />1 <br />54 <br />GHARBROILER 037 <br />87 <br />1 <br />&1 <br />SMOKER "66 <br />150 <br />1 <br />150 <br />TOTAL NATURAL GAS MBH REQUIRED: <br />roil <br />REQUIRED GAS LINE SIZE: 2" <br />NOTES: <br />1. INTERIOR GAS PIPING IS SIZED BASED ON A 100 FOOT <br />DEVELOPED LENGTH OF PIPE. <br />2. EXTERIOR GAS PIPING UP TO AND INCLUDING THE GAS <br />METER IS TO BE PROVIDED AND SIZED BY THE GAS <br />COMPANY. <br />3. GAS PIPING IS SIZED BASED ON 2018 FLORIDA FUEL GAS <br />CODE TABLE 402A(2). <br />4. MBH RATINGS ARE AS CALCULATED BY THE <br />MANUFACTURER <br />5. GAS PIPING IS SIZED FOR A DELIVERY OF OB PSI WITH A <br />14" WC. <br />6. ALL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL <br />PIPE, WELDED AND SEAMLESS. <br />'I. ALL BRANCH TAPS FROM GAS PIPING MAINS MUST BE <br />MADE OFF OF THE TOP OF THE PIPE. <br />S. GAS PIPING AND INSTALLATION WILL BE IN <br />ACCORDANCE WITH FLORIDA BUILDING CODE - FUEL <br />GAS AND ALL APPLICABLE CODES AND REGULATIONS. <br />S. PROVIDE PRESSURE REGULATING VALVE TO ADJUST GAS <br />LINE PRESSURE IN ORDER TO ACCOMMODATE TOTAL <br />MBH DEMAND. <br />10. IF PRESSURE REGULATING VALVES ARE REQUIRED AT <br />FIXTURES, THEY SHALL BE VENTLESS TYPE WHEN <br />INSTALLED ON INTERIOR OF BUILDING. <br />III. PROVIDE THERMOSTATIC MIXING VALVES AT ALL <br />LAVATORIES AND HAND SINKS, SET AT NO MORE THAN <br />IIOIF. <br />GAS DEMAND SCHEDULE <br />;1 WATER 4 GAS PLAN <br />--11 SCALE: 3/16" ■ I'-011 <br />I. ALL WORK SHALL COMPLY WITH ALL APPLICABLE <br />LOCAL AND STATE CODES AND AUTHORITIES HALING <br />JURISDICTION. <br />2. PLUMBING CONTRACTOR SHALL SECURE AND PAY <br />FOR ALL REQUIRED PERMITS AND ARRANGE ALL <br />REQUIRED INSPECTIONS. <br />3. ALL CONTRACTORS SHALL EXAMINE THE SITE AND <br />REVIEW THE DRAWINGS AND SPECIFICATIONS PRIOR <br />TO SUBMITTING A PROPOSAL, <br />4. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION <br />OF ALL EXISTING UTILITIES IN FIELD PRIOR TO <br />STARTING WORK <br />5. PLUMBING CONTRACTOR SHALL COORDINATE HIS / <br />HER WORK WITH OTHER CONTRACTORS IN <br />ESTABLISHING PIPE RUNS AND SPACE CONDITIONS. <br />6. ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, <br />CHASES AND FURRED SPACES OR BELOW COUNTERS. <br />7. THE DRAWINGS AS PREPARED ARE DIAGRAMMATIC <br />BUT SHALL BE FOLLOWED AS CLOSELY AS <br />CONSTRUCTION OF THE PROJECT AND THE WORK OF <br />THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS <br />INDICATED ARE APPROXIMATE. COORDINATE EXACT <br />LOCATIONS AND REQUIRED CLEARANCES WITH <br />EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO <br />INSTALLATION. <br />S. REFER TO EQUIPMENT SCHEDULE AND EQUIPMENT <br />SPECIFICATIONS FOR EXACT LOCATIONS OF PLUMBING <br />CONNECTIONS. <br />9. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 <br />P.V.C. WITH DRAINAGE PATTERN FITTINGS. <br />10. ALL WATER PIPING SHALL BE TYPE "L" COPPER WITH <br />SOLDERED JOINTS. CPVC PIPING MAY BE USED IF <br />ACCEPTED BY JURISDICTION AND IF NO PLENUMS <br />EXIST. PROVIDE WATER HAMMER ARRESTORS EQUAL <br />TO JAY R. SMITH AT EACH FIXTURE GROUP. <br />11. SLOPE WASTE LINES 3" AND OVER, 1/8" PER FOOT. <br />LINES SMALLER THAN 3" SHALL SLOPED AT 1/4" PER <br />FOOT. <br />12. INSULATE ALL DOMESTIC HOT WATER PIPING WITH P <br />WALL "ARMAFLEX", OR EQUAL. <br />13. PROVIDE ISOLATION VALVES AT ALL FIXTURES. <br />VALVES SHALL BE CHROME FINISH. <br />14. ALL KITCHEN, PREP AREA AND SALES AREA <br />EQUIPMENT WILL BE FURNISHED AND INSTALLED. <br />EQUIPMENT WILL BE FURNISHED WITH TRIM, FAUCETS, <br />ESCUTCHEONS, ETC. PLUMBING CONTRACTOR SHALL <br />PROVIDE ALL ROUGH -IN TRAPS AND MAKE ALL FINAL <br />CONNECTIONS (SEE EQUIPMENT SCHEDULE). <br />15. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL <br />ALL GAS PIPING AND MAKE ALL FINAL CONNECTIONS. <br />16. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL <br />PIPE HANGERS, AND SUPPORTS IN ACCORDANCE WITH <br />THE LOCAL APPLICABLE CODES. <br />I-1. PLUMBING CONTRACTOR TO PROVIDE BACKFLOW <br />PREVENTERS AT ALL COFFEE MAKERS, BAGEL OVEN, <br />ICE MAKER AND ALL OTHER EQUIPMENT AS REQUIRED <br />BY CODE. <br />18, PLUMBING CONTRACTOR TO PROVIDE TRAP PRIMERS <br />OR TRAP SEAL ON ALL FLOOR DRAINS AS PER <br />APPLICABLE CODE <br />IS. ALL ROOF PENETRATIONS SHALL BE AT THE <br />CONTRACTOR'S EXPENSE. COORDINATE WITH OWNER'S <br />ROOFING CONTRACTOR SO AS NOT TO VOID ALL <br />EXISTING ROOF WARRANTIES. <br />20. ANY CUTTING OR PATCHING NECESSARY TO PERMIT <br />THE INSTALLATION OF ANY WORK UNDER THIS <br />CONTRACT SHALL BE THE RESPONSIBILITY OF THIS <br />CONTRACTOR <br />21. ENTIRE INSTALLATION SHALL BE GUARANTEED FREE <br />OF DEFECTS AND CONTRACTOR SHALL REPAIR <br />AND/OR REPLACE ANY DEFECTIVE MATERIALS OR <br />EQUIPMENT AT NO COST TO THE OWNER FOR A PERIOD <br />OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY <br />ENGINEER <br />22. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF <br />THE ARCHITECT / OWNER <br />23. DEVIATION FROM MATERIALS, METHODS, OR <br />PROCEDURES SET FORTH HEREIN MUST BE <br />APPROVED, IN WRITING, BY ENGINEER PRIOR TO <br />SUBMISSION OF BID, ORDER, FABRICATION OR <br />INSTALLATION. ANY AND ALL QUESTIONS AS TO THE <br />INTENT OF OR PROCEDURES SET FORTH IN THESE <br />DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF <br />THE ENGINEER PRIOR TO SUBMISSION OF A BID. LACK <br />OF KNOWLEDGE OR UNDERSTANDING OF THE PLANS <br />SHALL NOT JUSTIFY ANY CLAIMS OR ADDITIONAL <br />COMPENSATION. <br />24. PROVIDE THERMOSTATIC MIXING VALVES AT ALL <br />LAVATORIES AND HAND SINKS, SET AT NO MORE THAN <br />110"F. <br />25. ADDITIONAL FIRE SPRINKLERS REQUIRED IN DINING 112. <br />FLUM8ING GENERAL NOTES <br />COLD WATER -- - - - - -- <br />HOT WATER ---------------- <br />GAS.......................... <br />EXISTING GAS ...... ...... ...... ...... <br />- - <br />FILTERED WATER ...... <br />FLUM51NG LEGEND <br />REVISIONS <br />BY <br />00 <br />�00 <br />CO <br />a� ro ti <br />S ti <br />N in E u cxd <br />/ ro• <br />U <br />� C � <br />CO CuJ NC\1 ro <br />O <br />3 <br />o N <br />ti <br />ti o <br />ti a <br />N <br />M <br />�1 <br />1 <br />i <br />ppOppO000000 <br />QO000O G°°°o°e00o ° O <br />NO <br />° <br />o PE 1 <br />° o <br />STATE OF ° <br />°�R11- 0`� 4Oti00000 <br />o °°°°°°. <br />moos'/OyAL(�� <br />pono <br />GARLAND PATTERSON, P.E. <br />FL Lic. No.: 14175 <br />MAY 25, 2021 <br />mo <br />0 <br />U m °' <br />Z <br />c((ONz° <br />:11 <br />a <br />U <br />Q r O z r- <br />O_ 'ovNiv <br />od <br />❑ 0SOON <br />J mrno <br />LL No CON <br />_ L 0 L <br />N V <br />C,Lo�Q . o <br />C U <br />G � O <br />L cy <br />O <br />N <br />C m <br />I <br />_° oM <br />� � C <br />c Q ono <br />m m <br />w0 <br />o o <br />� <br />c � C <br />osa <br />to <br />0 Z to 0 <br />c O N <br />m N <br />Date: 05. 17. 21 <br />Scale: AS NOTED <br />Project Mgr: DG <br />Drawn: BMD <br />Job: 18-083 <br />Sheet <br />P3 <br />14, <br />
The URL can be used to link to this page
Your browser does not support the video tag.