:R <br />FIRST FLOOR ELECTRICAL PLAN B <br />1/411 = 1 1-011 <br />LINE OF ROOF <br />--I ^IAf <br />SECOND FLOOR ELECTRICAL PLAN B <br />1/411 = 1 1-011 <br />I ELECTRICAL NOTES: I <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3'FROM BATH DOOR AND AT <br />LEAST 6'FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY, <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />10- <br />#15 copper to lights & outlets <br />NEMA 1 <br />00- <br />200 AMP <br />#12copperto2Oampckts <br />100- <br />#10-2 copper to WH <br />0- <br />I I <br />#10-3 copper to Dryer <br />METER <br />2/0or4/0SERAIu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />=2) <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 ANDI <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />0- 'L 0.11 <br />k Relip"M Ikbz— - <br />avid aWo"I 11 <br />comp vtt Ith idillo <br />Pkans W�k'" khe <br />tot <br />'bTa <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />L <br />SWITCH— <br />L <br />4 1/2" <br />DOORJAMB — <br />DUPLEX <br />OUTLET <br />TRIM <br />BASE ---- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL----,,,,, I- % F_ <br />CD <br />�_SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />11 OV DUPLEX OUTLET AT 12" <br />1 10V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />11 OV DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />11 OV DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 11 OV DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />11 OV QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />11 OV DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />---a DIMMER SWITCH AT 36" <br />—0 PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />WALL MNT FIXTURE NOTE: <br />� 0-3� 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />�OZ 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />�OZ 50W MR1 6 4" LOW VOLTAGE OWNER <br />,0_8_� 50W PAR20 NFL 4" MINI ROUND RECESS <br />-100 � 5OW PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />@ COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />03 SMOKE DETECTOR <br />ru-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= <br />SINGLE 24" FLUOR STRIP <br />=D-24= <br />DOUBLE 24" FLUOR STRIP <br />= U-36 <br />UNDER CABINET 36" <br />—S-36— <br />SINGLE 36" FLUOR STRIP <br />= D-36 = <br />DOUBLE 36" FLUOR STRIP <br />—S-48— <br />SINGLE 48" FLUOR STRIP <br />— D-48 — <br />DOUBLE 48" FLUOR STRIP <br />24"CLG MNT WRAPPED FLUOR LIGHT <br />1 48 48"CLG MNT WRAPPED FLUOR LIGHT <br />r77 24:R 24" VANITY LIGHTING <br />R—= 36 -FR 36" VANITY LIGHTING <br />48=FFFFR 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />INTERCOM SPEAKER AT 6-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />A/C REGISTER <br />OT THERMOSTAT <br />[M SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />C14 <br />C) <br />LO <br />7 Lf) <br />C) <br />00 <br />LO <br />LL. <br />r_1 <br />2� <br />w <br />0 <br />w <br />z <br />V) LO E <br />> CD C' o <br />-i-_ '0 q <br />0 CO <br />(y) <br />") <br />4- ::) C) co C') <br />V) U Cl) <br />C') <br />U '0 <br />0 L L Or- < <br />10 < <br />U 6 . <br />LU Q_ <br />U <br />00 E �2 <br />C:) 00 <br />LU <br />w <br />w 0 <br />W w w 0 <br />W�-< M2-< <br />02-j< - �Jyzl� z <br />0 <br />Y_ < <br />< I. <br />w 0�:0�6LL000-0 <br /><SR-ww 0z200"-P_ <br />D 0 <br />a U) w � zo , 0, EE 0 0 C'o <br />Z �w <br />0 z < <br />z 0 <br />Z) <br />0 0 <br />0 <br />0 z <br />(/) W w Z75 <br />IL > Lu Lu W <br />_j (D [L w <br />z y 0 LL <br />< LU Fn Z Lu Z <br />< 0 0 <br />D <br />< _j <br />0 0- <br />w 000- <br />LL <br />0 Lu 2�<,—�W232� <br />OT —0 D 0 Y z <br />g <br />LL < 0 < LL <br />CMO <br />0 <br />�z 0 <br />CN <br />w <br />0 I-_ <br />Z) <br />U) b <br />(0 0 <br />0 F2 CY) 0 <br />< w C0 rl- <br />Lq <br />_j <br />"t <br />nu) <br />LL <br />_�-1 <br />z <br />w < Lq <br />cy) <br />00 <br />< <br />Z C) <br />z <br />W <br />w <br />_j 0 <br />0 <br />(.0 <br />'t <br />CN <br />N <br />co <br />N <br />co <br />N <br />0 <br />CN <br />C) <br />N <br />0 <br />N <br />4 <br />4 <br />0 <br />C� <br />0 <br />C� <br />0 <br />C� <br />C� <br />C) <br />C3 <br />1 001 <br />Cl) <br />I — <br />I <br />I <br />to <br />M <br />C) <br />CD <br />C) <br />C) <br />0 <br />N <br />C) <br />N <br />a <br />N <br />C) <br />N <br />0 <br />N <br />CD <br />C) <br />6 <br />C� <br />Ob <br />R <br />U� <br />0� <br />A <br />C14 <br />CY) <br />(0 <br />4 <br />CD <br />'- <br />CD <br />P, <br />C:) <br />"- <br />CD <br />(61 <br />0 <br />0 <br />Lo <br />a) <br />C) <br />C) <br />0 <br />c) <br />-'t <br />c <br />a <br />C) <br />LO <br />to <br />r-- <br />CO U) <br />Z <br />Z 0 <br />w <br />0 W Fn <br />LLI 1­ 5; <br />0 17- <br />0 <br />0 <br />EE 0 <br />3: < <br />0 a- <br />0 <br />O� LU -S <br />T <br />up) <br />Z <br />0- <br />UJ l­— <br />w <br />0 <br />< <br />co <br />I-— z <br />0 LU <br />Z <br />00 <br />>- <br />LIJ 0 <br />ry) <br />z w <br />Z Z LL <br />CD <br />LU fN <br />0<f <br />< 1-- <br />-1 2 z <br />< <br />0 <br />a- >- ' <br />Z co <br />z <br />z <br />0 <br />ry <br />z <br />0 <br />0 <br />0 0 <br />z <br />A6 <br />< <br />z <br />z <br />W, <br />C14 <br />Uj <br />04 <br />0 <br />LAST PLOT DATE <br />> <br />May. 9, 23 <br />zA__j <br />0 <br />1ST & 2ND FLOOR <br />ELECTRICAL <br />PLAN <br />B <br />