ROOF FINISH PER <br />12 <br />15 ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOFTRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />V A ALUMINUM <br />Nam: REFER TO STRUCTURAL SOFFIT SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />SOFFIT DETAIL - 8" TRUSS HEEL <br />6 <br />3/411 1 <br />1-011 <br />-ROOF FINISH PER <br />12 ELEVATION <br />15 <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />ALUMINUM <br />SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />DETAIL <br />aSOFFIT <br />7 <br />1-011 <br />3/411 1 <br />6" <br />4" 4" <br />0 CD <br />00 00 <br />EPS <br />FOAM <br />BRACKET DETAIL <br />8 <br />ill= 11-011 <br />5" <br />3" 811 <br />TEPS <br />OD -1 00 <br />- <br />FOAM <br />BRACKET DETAIL <br />9 <br />1-011 <br />lot 1 <br />PROVIDE FILLED SOLID CMU ABOVE <br />LINTEL TO TIE BEAM <br />FLASHING <br />PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />(S) H 1 OA-2 STAGGERED, SEE DETAIL 11/A5 <br />ROOF FINISH PER ELEVATION <br />UNDERLAYMENT <br />ROOF SHEATHING <br />ELEV AT 8'-8" <br />T.O.M. <br />___15 METAL DRIP <br />EDGE <br />(S)A23 <br />2X4 FASCIA <br />ALUMINIUM <br />2'-0" WRAP <br />(S) A23 ALUMINUM <br />SOFFIT <br />PT 2X4 LEDGER ATTACHED TO <br />WALL W/ 3/16" TAPCONS W/ <br />MIN 2-1/2" EMBEDMENT 6" O.C. <br />BTM AT 7'-6" <br />SOFFIT DETAIL <br />10 <br />9-011 <br />3/419 1 <br />PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />STAGGERED <br />04 <br />8" 1 I -Of, 11-011 11-01, 11-01. <br />LEDGER DETAIL <br />If <br />4-011 <br />3/4 = 1 <br />6" X 1 "TH K <br />CEMENT <br />PLASTER BAND <br />16" X 1 "THK - <br />CEMENT <br />PLASTER Ll'-3" <br />BAND T' <br />DRIP CASING BEAD <br />AT BOTTOM OF <br />STUCCO BAND <br />6" X I "THK <br />CEMENT <br />PLASTER BAND <br />5/8" STUCCO ON <br />CMU <br />7/8" STUCCO <br />ON FRAME <br />MID -WALL <br />WEEP <br />SCREED <br />5/8" STUCCO <br />ON CMU <br />CASING BEAD W/ <br />WEEP HOLES <br />OVER FLASHING <br />n. <br />N4 <br />\1 <br />1-31' <br />— CASING BEAD W/ <br />WEEP HOLES OVER <br />FLASHING <br />SHINGLE <br />,— ROOF <br />12 <br />1� LID <br />] �t 15 <br />L L <br />CONTROL <br />J01 LW L] <br />INTS U,�],L] L <br />z <br />71 9 ui <br />:E <br />CONTROL — <br />JOINTS <br />FRONT ELEVATION B <br />1/411 = 1 1-011 <br />GRADE LINE <br />�E ION B <br />3 11 if = 1 1-011 <br />1/8 <br />12 <br />, 15 <br />2 <br />F—MID-WALL <br />,/ WEEP SCREED <br />F__ - ___ I <br />CASING BEAD W/ <br />WEEP HOLES <br />OVER FLASHING <br />ELEV AT 8'-8" <br />T.O.M. <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />12--011 13'-B" 12'-0" 1 <br />F- <br />= C? <br />0 <br />CONTROL C"4 CONTROL <br />JOINT JOINT <br />MID -WALL <br />WEEP <br />SCREED <br />ra <br />- — - — - — - — ---- - <br />GRADE LINE STUCCC <br />RIGHT ELEVATION B ON CMU <br />1/811 = 1 1-011 <br />lot <br />CONTROL--,,,,,,., <br />JOINT <br />A/C UNIT 2'-0 ;1-1/ <br />AND PAD-4 =,q <br />121-411 <br />CONTROL <br />� JOINT <br />MID -WALL <br />WEEP <br />SCREED <br />----------------- <br />Z_ GRADE LINE <br />LEFT ELEVATION B <br />1/811 = 1 1-011 <br />ASSUMED GRADE <br />7/8" STUCCO <br />ON FRAME <br />ELEV AT 18'-0" <br />T.O.P. <br />It <br />V.011 <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />ELEV AT 8'-8" <br />T.O.M. <br />_:t <br />Z-011 A/C UNIT <br />/7�ND PAD <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />7/8" STUCCO <br />ON FRAME <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 10'-0" <br />24 OR FF <br />ELEV AT 8'-8" <br />T. 0. M. <br />—5/8" STUCCO <br />ON CMU <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />ELEV AT 18'-0" <br />T.O.P. <br />7/8" STUCCO <br />ON FRAME <br />CASING BEAD W/ <br />WEEP HOLES OVER <br />FLASHING <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />ELEV AT 8'-8" <br />T. 0. M. <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />'j. a., �l All 4 ^1 All <br />E �FJ�L N B <br />1/! �8 _0 <br />-7 t <br />CD <br />I <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS'NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC'OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE/ UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2,6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C 1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />UL 2 1 <br />Virtual Review Assist, I c. <br />Plans Review completed and pprakt <br />p r'� <br />for compliance with the 2020 FBIC 4tidi <br />by Debra Anne Klahr PX 300 � <br />GENERAL NOTES: <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9/12) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />ROOF VENT CALCULATIONS: <br />NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />FORMULA = S.F. / 150 (1/150) * 144 (TO CONVERT TO SQ. INCHES) <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA = 1222 SQ FT <br />VENTILATION REQUIRED = 586.56 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 276 SO IN <br />VENTILATION PROVIDED AT SOFFIT = 1008 SQ IN <br />ATTIC VENTILATION <br />ATTIC VENTILATION TO BE IN COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 7TH EDITION (2 2 RE IDENTIAL R806. <br />1 0 N S <br />THE MINIMUM NET FREE VENT LAT G AREA SHALL BE 1/150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 1/300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET A E <br />OF THVE SUR <br />VERTICALLY) BELOW THE RIDGE OR HIGHEST POINT SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN. <br />� ALUES TO BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />VR I DGE VENTS - 18 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />*OFF-RIDGEVENTS -138SQ.[N,OFNETFREEAREA/UNIT <br />* SOFFIT VENTS - 7 SQ. IN. OF THE NET FREE AREA / SQ. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION, THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />LOMANCO DECK -AIR - 9 SQ. IN. OF NET FREE AREA / FT. FOR SHINGLE <br />36 SQ. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWSSLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TE TED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACEABILITY TO MANUFACTURER AND PRODUCT <br />C0 <br />04 <br />00 <br />LID <br />00 <br />U- <br />0 <br />LLJ <br />z <br />LC") E <br />'u <br />L. '0 <br />In 6 <br />cy) co <br />co 2 <br />Ln <br />U -8 cc-'O) <br />E I, <br />C <br />0 U-8 <br />, 0 < <br />Ln <br />'0 Q) < <br />U <br />Lu "Ir <br />(D <br />000 E �2 <br />W W W <br />Lj W 0 <br />LU �_ LU 0z W z <br />Lu 0 <br />-§ �2� 0 0 <br />0 <br />< < 0 <br />F- 1-- <br />it:)--i 0�! LL C-) 0 LL _j <br />< 0 X _j (0 x V) 00 <br />x 0 <br />0 Z LL I, <br />WW W 9 <br />0 0 0 <br />0 Z <br />uj2zo"Fmo� <br />(D CL > W ED Uj W V5 W w � =) <br />Z Z LL 0 <br />z !Ie 0 0 Lu (L <br />0 W ui z L) 0 IL <br />(L) <br />U- <br /><0W P_ a z < <br />zwzg< <br />OW 0 0 �e <br />< < <br />U- 0 <br />C:) <br />C) <br />r-4 <br />Z Lu <br />0 <br />V) <br />> <br />Q <br />t; <br />C:, <br />0 <br />N <br />z <br />< <br />Lr) <br />LL <br />z <br />Lu <br />Q� <br />Ce <br />Ln <br />Cti <br />'.j <br />< <br />z <br />< 00 <br />F--� <br />z <br />uj <br />W <br />C:) <br />CN <br />N <br />M <br />C%j <br />n <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />,-' <br />CD <br />A <br />T-- <br />4 <br />V- <br />C� <br />C:) <br />C� <br />C) <br />C� <br />CD <br />CD <br />6 <br />o6 <br />ai <br />N <br />N <br />N <br />o <br />N <br />C) <br />N <br />C:) <br />N <br />CD <br />N <br />C:) <br />N <br />0 <br />N <br />C) <br />N <br />C) <br />CD <br />C6 <br />6 <br />6 <br />6 <br />Ob <br />C� <br />A <br />C� <br />N0 <br />CNLID <br />Cn <br />N' <br />M <br />'It <br />LO <br />um) 'It <br />I Cr <br />00 <br />Z Z <br />z 2 <br />Lu <br />W W CO <br />u <br />mo <br />< <br />F- <br />0 <br />F. <br />0 <br />0- z rr <br />LO -0 <br />z <br />zw�-p <br />Q� I.- <br />< <br />F- <br />Lu =) ZZ <br />00 0 " <br />L0 <br />Z <br />I,.- M: Z <br />W <br />Z <br />W 0 <br />z <br />azz <br />>_ <br />LU <br />2 0a <br />0 <br />0 <br />e < F- <br />-3 2 z <br />a- >- LLI <br />CN <br />< <br />z T-4 <br />z <br />T) z z <br />=<0 <br />3 <br />e. <br />L) <br />CL <br />0 0 <br />z <br />A5 <br />z <br />z <br />_W1 <br />Cf) <br />C*4 <br />LAST PLOT DATE <br />>o <br />May. 8,23 <br />z4­0 <br />0 <br />EXTERIOR <br />. j <br />ELEVATIONS & <br />ROOF PLAN <br />B <br />