My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6648 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6648 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 6:37:21 PM
Creation date
2/19/2025 8:33:22 AM
Metadata
Fields
Template:
Building Plans
Street #
6648
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIANIOND-MESH <br />EXPANDED METAL. LATH ATTACHIVENT. <br />WALL SHEATHING <br />16GAx 1°2" LONG f3,144'-11' CROVJN1 <br />STAPLES (a W` 0. C, VER T BETWEEN I I l 1 EGAxl 1 /2 LONG (314%1" <br />STUDS (NOTED THUS:—) - OFFSET I I I [ I I CROWN) STAPLES6" <br />STAPLES SET"WEEN STUDS AS SHOWN — O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />ETAL T ATTAC H M E NIT DETAIL <br />REV. 09.24.21 SOA" LE; 3 1`-0 <br />iDETAIL EXCEEDS THE REQUIREMENTS FOR FBCF 703.7.1 LATHF <br />'*ONLY APPLIES TO LENNAR TPA JAX*` <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4%1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMINSi MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C 1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />5'-0" - <br />STUB -OUT FOR "' <br />GAS METER O — <br />0 <br />CV <br />H <br />C G <br />C <br />O C <br />a _ <br />o <br />10 <br />� <br />Q <br />o <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />F-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />T (3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />IT-4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />tr <br />w <br />m <br />0 <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />Rim'F I INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + t + + + + + + + <br />+ <br />+ <br />+ + + + + + + t o <br />+ + + + + t + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + ED <br />+ + + + + + + + + + + t + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />CYO <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />\-RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />t + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH <br />2-3/8 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING <br />CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x—+ 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x—+ 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />90 2.0 <br />2 x — lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />x <br />FILL CELLS STD. 900 HOOK r— BOND BEAM <br />1 <br />w <br />........ ........ ......... <br />IM <br />Q STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />OOC <br />:.......... <br />:......... <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />}Small gap <br />2" <br />max. 4 max. <br />Clinch nails <br />when <br />possible 1 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP TOP sides b 6". -Hangers with side nailing. <br />@ y- Hangerswithsidesnotcontaining WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 1F,nnlh <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />"Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.' <br />consideration. Check <br />local building <br />code for appropriate <br />1/16 <br />Lor=21 <br />details in <br />One 10d box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />J <br />for <br />each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />MotG-, ❑ to <br />6" A 1Yz" ROUND HOLE MAY 6,e 6�e DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c, for all joist <br />blocking panel *Non <br />-stacking walls <br />require additional consideration.— <br />Any 16°" joist . <br />S pan (ft) <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE, THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Yz" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BC15000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- d <br />BCI6000sZ' <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/(22) <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) ' <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />1.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />,a C <br />Backer block (12" wide min.) III III _ <br />Nail with 10-10d nails. - <br />Install tight to top flange. e . <br />SLEEVE THRU STEM <br />SEE PLAN FOR °• a . • <br />*N <br />FOUNDATION INFO a <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE REINF. SEE PLAN <br />o —I I <br />A, Iil <br />I =1 a a. <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />"�o LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18) 10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />_ I • 11=1�1=1�1 III III a �IIIIIII� <br />' <br />I <br />I <br />JUL <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FN . <br />ir aa( Review Assisi <br />an <br />for compliance with �theeted 20201 <br />by Debra Ann �r p <br />PVC OR SCH40 � <br />TOP (2) #5's x 4' 0" <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION i I <br />�a •� <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />-----4 ca <br />1411� =I 11=1a 1-1 11- <br />,: I'_ <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />ce) <br />N <br />0 <br />N <br />00 <br />e� <br />LO <br />✓� <br />00 <br />U� e <br />i <br />s <br />IdUJ <br />? 0, <br />' <br />0 <br />w <br />0 <br />z <br />Q <br />^0 <br />Q) o -. o <br />W <br />L C 0 o, U <br />N co oo <br />V) <br />I. ri <br />j�: <br />V 0 off^ U cMi) <br />Y/ ' u o <br />rn <br />0) <br />°N <br />_ <br />p LL o a Q <br />N <br />0 <br />V w Q� <br />E <br />-V <br />L. cO .2) <br />0 C5 a N <br />- i- _0 <br />can <br />LIJ <br />(D WU <br />Ld w <br />w � ¢ o: w ' QY z of <br />WU)U-0 LL <br />Q <br />QDX�V) W <br />O00 <br />�vi��0z0E00m0z <br />J��'ZYOZUJ zLL <br />0 <br /><0IL <br />0 o Z <br /><1 w- gN� �wij20 <br />< <br />O� o �' o¢zcc <br />U- Q O I— Q U- <br />Lo0 <br />O <br />N <br />Ow <br />I— <br />r-i <br />1 <br />`M CD <br />z <br />Q V M L <br />U-) <br />Q UJ <br />I� > <br />Q to <br />G <br />Z U <br />00 <br />UI <br />W <br />O <br />20 <br />N <br />N <br />O <br />M <br />N <br />O <br />M <br />` N <br />O <br />N <br />' <br />N <br />Ad4 <br />N <br />O <br />I� <br />O <br />CD <br />0 <br />Inc' <br />approved <br />'C 7th Edition <br />O <br />ao <br />O <br />0i <br />o <br />30o <br />O <br />O <br />k 00 <br />0 <br />0 <br />0 <br />0 <br />0,0 <br />0 <br />CD <br />0 <br />CD <br />C)N <br />N <br />CV <br />N <br />N <br />CV <br />N <br />N <br />O <br />C)et <br />O <br />CD <br />r <br />00 <br />C)r <br />N <br />M <br />OO <br />'t <br />0 <br />r- <br />0 <br />• O <br />0 <br />S <br />O <br />O <br />O <br />r <br />N <br />0 <br />N <br />0 <br />0 <br />N <br />> <br />0 <br />CV <br />0 <br />cli <br />0 <br />d <br />0 <br />LO <br />0 <br />(fl <br />0 <br />ti <br />1 Cr <br />M (� <br />Z Z <br />O <br />w <br />�/`/ <br />o U) <br />Q O <br />Q <br />�o�o <br />a <br />-0 <br />Oa=Q <br />LO -0 <br />Z <br />ZO�~� <br />T— <br />~maz <br />= <br />H = Z <br />Z j J <br />i— <br />2 z <br />LL <br />1� <br />Z Z <br />CD <br />� �` <br />0 <br />�a�w <br />U) <br />N <br />z T,,,I <br />U) Z <br />a 0 <br />• <br />z <br />U <br />U <br />J <br />a 6. <br />Oo <br />00 <br />Z <br />Q <br />Z <br />z <br />LU <br />WSN1 <br />co <br />O <br />N <br />O <br />LAST PLOT DATE <br />May. 8, 23 <br />STRUCTURAL <br />z 40 <br />0 <br />J <br />DETAILS <br />
The URL can be used to link to this page
Your browser does not support the video tag.