12 ROOF FINISH PER <br />125 ELEVATION <br />ROOF SHEATHING 1'-4" <br />1" 1" <br />MANUFACTURED <br />ROOF TRUSS <br />-METAL DRIP EDGE co <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />ALUMINUM ❑ <br />NOTE: REFER TO STRUCTURAL SOFFIT SOFFIT <br />12" SQ CMU COLUMN, <br />DETAIL SF01 SHEET SS FOR SOFFIT SMOOTH STUCCO <br />ATTACHMENT DETAIL —FINISH <br />6 SOFFIT DETAIL <br />3/4 — 1 -0 <br />ROOF FINISH PER CO <br />12 ELEVATION <br />15 <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />ALUMINUM STUCCO BANDi <br />SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />04 <br />7 SOFFIT DETAIL <br />3/4 — 1 -0 <br />11 COILUMN DETAIL <br />3/4 — 1-011 <br />PROVIDE FILLED SOLID CMU ABOVE <br />LINTEL TO TIE BEAM <br />FLASHING <br />CASING BEAD WITH WEEP HOLES <br />2" PT 2X8 LEDGER ATTACHED TO WALL <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />(S) H10A-2 STAGGERED, SEE DETAIL 13/A5 <br />— ROOF FINISH PER ELEVATION <br />UNDERLAYMENT <br />ROOF SHEATHING <br />STUCCO DETAIL - 12 - - -- ELEV <br />T O MAT 8'-0" <br />8 3/4if = 1'-0" 1 5 METAL DRIP <br />EDGE <br />(S) A23 <br />2X4 FASCIA <br />1-1/2" THK ALUMINIUM <br />2'-0" WRAP <br />(S) A23 ALUMINUM <br />SOFFIT <br />00 ��PT 2X4 LEDGER ATTACHED TO <br />WALL W/ 3/16" TAPCONS W/ <br />MIN 2-1/2" EMBEDMENT 6" O.C. <br />3" BTM AT 7'-6" <br />2"�71 2" <br />12 SOFFIT DETAIL <br />3/4 = 11-011 <br />9 STUCCO DETAIL <br />3/4" = 1'-0" <br />PT 2X8 LEDGER ATTACHED TO WALL 6„ <br />W/ 3/8" X 5" TITEN HD AT 12" O.C. <br />1 1„ 4 I STAGGERED <br />10 4 <br />N <br />(V N o 0 0 <br />0 0 <br />O 00 O 00 <br />EPS 8" V-0" <br />iv FOAM iti10 <br />BRACKET DETAIL LEDGER DETAIL <br />10 111 = 11-011 13 3/411 = 11-011 <br />6" SCORED <br />BAND <br />7/8" STUCCO <br />FRAME <br />6" X 1"THK <br />CEMENT <br />PLASTER BAND <br />16" X 1"THK <br />CEMENT <br />PLASTER BAND <br />DRIP CASING BEAD <br />AT BOTTOM OF <br />STUCCO BAND <br />5/8" STUCCO ON <br />CMU <br />10 <br />A5.A <br />� 1 <br />CONTROL <br />JOINTS <br />its ■■' • • - • <br />MID -WALL <br />WEEP <br />SCREED <br />FRONT ELEVATION A <br />1 /4" = 1'-011 <br />�NII�111�1�., • <br />z= M <br />7/8" STUCCO 2 i�_ <br />ON FRAME N = CONTROL 5 <br />JOINT <br />MID -WALL <br />WEEP <br />SCREED 3\ <br />- - <br />5/8" STUCCO r <br />ON CMU - - - _ <br />Sk <br />GRADE LINE <br />REAR ELEVATION A <br />1 /8" = 1'-01 <br />1 <br />12'-0" 13'-8" <br />CASING BEAD W/ _ <br />WEEP HOLES o <br />OVER FLASHING 5 2 CO JOIOOT W <br />11- <br />A5.A - - - - - - — <br />MID -WALL <br />WEEP <br />CREED <br />I I <br />I <br />GRADE LINE <br />RIGHT ELEVATION A <br />1 /811 = 1 1-011 <br />12 <br />51 <br />12'-0" <br />z 2 <br />=O <br />CONTROL W <br />JOINT <br />12 <br />5� <br />A/C UNIT 2'-0" <br />AND PAD <br />19 <br />18'-0" <br />CM <br />LEFT ELEVATION A <br />1 /811 = 1'-011 <br />SHINGLE <br />ROOF <br />z= <br />:O <br />v <br />ti <br />T.O.P. <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />ELEV AT 8'-8" <br />T.O.M. <br />L/SS <br />® A/C UNIT <br />AND PAD <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />12 <br />-15 <br />12'-0" <br />CONTROL <br />JOINT <br />IN <br />5/8" STUCCO <br />ON CMU <br />_ <br />CONTROL <br />JOINT _ <br />MID -WALL <br />WEEP <br />12'-0" <br />SCREED <br />DRIP CASING BEAD---/ <br />AT BOTTOM OF <br />STUCCO BAND <br />GRADE LINE <br />I <br />ELEV AT 18'-0" <br />T.O.P. <br />CASING BEAD W/ <br />WEEP HOLES <br />OVER FLASHING <br />7 <br />5. <br />ELEV AT 10'-0" <br />f� <br />2ND FLOOR FF <br />I � <br />ELEV AT 8'-8" <br />u T.O.M. <br />I <br />I <br />I <br />I <br />h_lrt <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />ASSUMED GRADE <br />STUCCO <br />�7/8" <br />ON FRAME <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 10'-0" <br />2ND FLOOR FF <br />2 <br />ELEV AT 8'-8" <br />T.O. M. <br />2'-0" <br />A/C UNIT <br />AND PAD <br />ELEV AT 0'-0" <br />T-8" 7'-4" <br />7/8" STUCCO 1 <br />ON FRAME <br />ELEV AT 18'-0" <br />T.O.P. <br />ELEV AT 10'-0" <br />2'-0" <br />2ND FLOOR FF <br />_ ELEV AT 8'-8" <br />T.O.M. <br />----5/8" STUCCO <br />ON CMU I <br />ELEV AT 0'-0" — <br />1 ST FLOOR FF <br />1'-0" <br />SLOPE 5:12 <br />SLOPE <br />-5:12 <br />N----- — <br />W 4'-0" OFF <br />Oc'4 RIDGE <br />U) Lo ROOF <br />VENT <br />W <br />a_ <br />ON <br />J <br />SLOPE I SLOPE <br />—5:12 5:12� <br />1 ROOF PLAN A <br />1 /8 if= 11-011 <br />SLOP <br />SLOPE 5:12 _ <br />6" <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS, <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />\/R <br />A <br />2 1 20, 3 <br />Virtual Review Assist, Inc <br />Plans Review completed and appro d <br />for compliance with the 2020 FBC 7th Edi ' <br />by Debra Anne Klahr PX2300 <br />GENERAL NOTES: <br />* G.C. VERIFY ROOF PITCH <br />ROOF PITCH VARIES PER SUBDIVISIONS (5/12 PR 5.9/12) <br />IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ROOF <br />SLOPE REQUIREMENTS WITH TRUSS MANUFACTURER. <br />ROOF CRITERIA <br />- 12" OVERHANG U.N.O. <br />- PLUMB CUT FASCIA <br />- ROOF PITCH PER ELEVATION <br />- WINDLOAD CALC. PER ASCE 7-98 (VARIES BY LOCATION) <br />- SHINGLE LOADING <br />ROOF VENT CALCULATIONS: <br />NOTE: VERIFY WITH GENERAL CONTRACTOR ALL ROOF VENT <br />LOCATIONS, QUANTITIES, AND SIZES. ROOF VENTS SHALL BE <br />INSTALLED FOR A MIN. OF VENTED AREA AS LISTED BELOW OR <br />EQUIVALENT SYSTEM PER FBC 7TH EDITION (2020) SECTION R806 <br />FORMULA = S.F. 1150 (1/150) * 144 (TO CONVERT TO SQ. INCHES) _ <br />NET SQ. INCH REQUIREMENT <br />ATTIC AREA = 1222 SQ FT <br />VENTILATION REQUIRED = 586.56 SQ IN <br />VENTILATION PROVIDED AT RIDGE = 276 SQ IN <br />VENTILATION PROVIDED AT SOFFIT =1008 SQ IN <br />ATTIC VENTILATION <br />ATTIC VENTILATION TO BE IN COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 7TH EDITION (2020) RESIDENTIAL R806. <br />THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE <br />AREA OF THE VENTED SPACE. THE VENTILATED AREA MAY BE <br />REDUCED TO 1/300 PROVIDED THAT AT LEAST 40% BUT NO MORE <br />THAN 50% OF THE REQUIRED VENTILATION IS PROVIDED IN THE <br />UPPER PORTION OF THE SPACE TO BE VENTILATED. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET (MEASURE <br />VERTICALLY) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, <br />WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY <br />EAVE OR CORNICE VENTS. <br />CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN, <br />VALUES TO BE VERIFIED WITH MANUFACTURER SPECIFICATIONS) <br />RIDGE VENTS - 18 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />* OFF -RIDGE VENTS - 138 SQ. IN. OF NET FREE AREA / UNIT <br />* SOFFIT VENTS 7 SQ. IN. OF THE NET FREE AREA / SQ. FT. <br />IF NOT ENOUGH VENTED SOFFIT IS PROVIDED DUE TO FIRE <br />PROTECTION, THE CONTRACTOR SHALL USE DECK -AIR OF OTHER <br />APPROVED MATERIAL TO PROVIDE SUFFICIENT IN -TAKE VENTILATION <br />* LOMANCO DECK -AIR - 9 SQ. IN. OF NET FREE AREA / FT. FOR SHINGLE <br />36 SQ. IN. OF NET FREE AREA / FT. FOR TILE <br />NOTE: <br />EXTERIOR WINDOWS, SLIDING DOORS AND EXTERIOR SIDE -HINGE <br />DOORS SHALL BE TESTED AND LABELED WITH A PERMANENT LABEL <br />PROVIDING TRACE ABILITY TO MANUFACTURER AND PRODUCT <br />i <br />F, <br />P <br />M <br />N <br />o <br />N <br />00 <br />Ln <br />R <br />C) <br />,n <br />t x r;. <br />z <br />w <br />�p� <br />`} <br />O <br />0 <br />z <br />Q <br />0 A, O L0 <br />W 6.0 �O q U <br />0 c`') N W <br />`"M � <br />NU O 0— u CIO c) <br />W E O o <br />rn o � o <br />V_/ �O '0- 6)Q <br />C U O^ N <br />n1 QN <br />QJ <br />W L � S= <br />W <br />W W <br />o � �; Uj <br />WI-Q =g-' 'W� zit z <br />Q�— J<OgiU0��0 <br />Q U <br />Q I— <br />0 0 0 <br />SOX ZL�LLL0Z2OJOF-<F <br />OcnQWE?5 OtEOOmZ� U <br />��LU a LU >zYO�';z'-0wo�a <br />Cn Z <br />QIL <br />�wOgF-��3gwp�UmQ <br />o o<z�Q <br />OW <br />U_Q O FaU- <br />f <br />a <br />O <br />O <br />(V <br />OW <br />�� N <br />�0 <br />z <br />1>4U <br />o <br />Q Ln J In <br />V_�x <br />U_ <br />Lu <br />z <br />F-- Q_M-.i <br />aUa� <br />z I- <br />WC:) <br />z � <br />J <br />Nce) <br />N <br />co <br />N <br />N <br />N <br />4 <br />O <br />r- <br />r <br />000 <br />O <br />O <br />o <br />o6 <br />6 <br />• , <br />co <br />-c-- <br />W <br />r- <br />co <br />T— <br />O <br />N <br />CD <br />NO <br />NO <br />O <br />O <br />N <br />O <br />O <br />N <br />M <br />O <br />N <br />0 <br />O <br />N <br />0 <br />N <br />N <br />O <br />N <br />M <br />N <br />4 <br />O <br />' <br />r— <br />r- <br />!P <br />r- <br />G <br />cp <br />O <br />N <br />O <br />N <br />NO <br />O <br />CDO <br />O <br />r- <br />r <br />0 <br />1Cn <br />N� <br />�r-ob <br />r— <br />N <br />M <br />o <br />4 <br />000 <br />6 <br />6 <br />ti <br />LO <br />� <br />Z Z <br />— z <br />OLij <br />W W to <br />UoEE0 <br />Q <br />L 1 <br />zi <br />OW�Q <br />ZW <br />t� <br />=co02 <br />F- Z <br />v <br />Z � J <br />Q'; <br />>-re2 <br />�ZZU_ <br />2 Z W <br />N <br />w N <br />a 00; <br />Og�z <br />UWZz <br />a w <br />• <br />z �. <br />z i <br />�Q0 <br />U <br />Ua <br />Oo <br />x <br />a <br />Z <br />Z <br />z <br />W <br />J <br />WCf) <br />O <br />>o o <br />LAST PLOT DATE <br />May. 8, 23 <br />EXTERIOR <br />4_j <br />z 0 <br />J <br />ELEVATIONS & <br />ROOF PLAN A <br />