Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />318" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4) SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />y:� •,: + �; ,� �.. MASONRY <br />WINDOW BL)CK- <br />;'.;, <br />�, 2) SEALANT JOINT <br />5) SEALANT FROM <br />•; .' : ;c;; ;�'; •' INSIDE EDGE OF <br />WINDOW FRAME <br />: ; `; r' ► , WINDOWBUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE' <br />6) TOOLED SFAL ANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME TC <br />WINDOW BUCK ALL THE WAY <br />AnOUND, INCLUDING SiLL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />,IAMB. SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HouSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />314" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />WEATHER <br />JE BARRIER & <br />LARILY SECURE <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONS (H <br />SELF -ADHERED FLASHI <br />BY LAPPING DOWN --^ •. <br />OVER RIM JOIST AND U10 <br />WALL BY 6 iN- <br />WEATHER \� <br />RESISITIVE \ <br />BARRIER SEAL TOPS l)F JQISTS <br />UNDER DECKING <br />ED FLASHING {SEE DETAIL WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW W P01 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING ----� <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF ADHERED FLASHING-, <br />OO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as 0 in each detail that corresponds to the <br />numbered items In the list of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of comer may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as npc:PSsary <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />82 <br />W PO4 <br />M <br />rt.r�rnlru rr-narnl�a 2\ <br />SELF -ADHERED FLASHING FwP07 <br />DECK JOIST <br />2x FRAMEWALL--- <br />TILE FINISH---, <br />1/2" DUROCK <br />8" CMU -- <br />4" OR 8" CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED <br />VINYL SHOWER PAN <br />V-4" PER PLAN <br />NEATi 1ER RFSISTIVE <br />L3AHf;IE. R <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERFOR SHEATHINC; . <br />3/4"-1" BEAD OF CC NSTR. <br />ADHF. SIVE TO BE A�PLIED UNDER --- <br />THRESHULU OF D( OR AND RETURN <br />UP JAMB 6" US = L 1 101) NAII BRAND / <br />OR EQUAL WEAT 11 R PRUL)i CAULKING 1 <br />SECTION -A (SL E DE: T 'wit WP02.) <br />SELF-ADHEREOUlf. THING <br />SEAL TOPS OF J )ISTS <br />UNDER DECKINC, <br />(SEE DETAIL WPi)T) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />E XTERiOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />SHOWER SEAT WP1 1 <br />SUBFLOOR <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />- SLOPE <br />0.3 in: 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />��.•� F3FAL1 or cc�NSTF; (0.6 cm : 30.5 cm) include flashing as described in Section R703.4- <br />ADHESiVE TUBE APPLIFDUNDEFt -SELF-ADHEREt� FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6°. USE LIQUID R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of water <br />NAIL BRAND OR ECAJAL WEAi HE EXTERIOR <br />PROOF CAULKING ----- iI -CEMT. FIN. within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means of <br />��- SELF -ADHERED FLASHING BUILDING PAPER <br />draining to the exterior water that penetrates the exterior cladding. <br />-� WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />` approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches. Where pints occur, felt shall be lapped not less than 6 inches. Other <br />approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The No.15 asphalt <br />felt or other a roved water -resistive barrier material shall b cont'n o t th t f II d t t d t tr t' d b Id <br />- RiM JOIST pp e i u us a e op o Wa s an ermine e a pens a Ions an ul Ing <br />appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based <br />sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper_ The <br />2 :. <br />- -�' 2 individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in <br />accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />W pQ2 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER W P03 Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />�* MECHANICALLY FASTEN IF RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />RUBBERIZED 1 <br />NEEDED IN CORNERS ADHESIVE 1 <br />INSTALL sEl F-ADHERED ASPHALT ADHESIVE <br />F I A SHING ,IANIR A HEAD THROUGH SELF -ADHERED R703.4 Flashing. Approved metal flashing, vinyl flashing, self-adhsred membranes and mechanically attached flexible flashing shall be applied <br />I't.A, HIND ',I E FLASHING f-SELF-ADHERED FLASHING shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied membranes <br />F-LAM;LD WIN0L )w7 <br />I g 9 PP <br />(SEE DETAIL wF'O1) used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to prevent the <br />SCORED entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF•AOHEREDFLASHING, �`e J3L C;r+F FCn:.i1rJO SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />RELEASE P4PFR rof.Ap s <br />EXTEND A MINIMUM i' AO:YESWE As SHOWN) contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />VERTICALLY FROM <br />Id BOTTOM OF flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD shall be installed at the following locations: <br />1.1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />- finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible fleshings <br />\� shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />2 following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />�4) manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details are <br />1 S not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall Incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />('� SELF -ADHERED FLASHING 1.3 1.3. In accordance with other approved methods. <br />W P05 INSIDE CORNER WP06 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/ `DMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground - 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />1 / . 6.6.At wall and roof intersections. <br />--- Watw Resistant Barrier 7. 7.At built-in Gutters. <br />'LF-ADHERED FLASHING -I <br />ITCH <br />HERFD FLASHING ^� <br />l I l <br />;2 <br />i4 <br />W P08 <br />PLASTER STOP •f <br />CONTINUOUS BACKER --.- <br />ROD & SEALANT <br />�A <br />;TRIP OF SAF <br />DRAINAGE PLAN <br />r� <br />4, • <br />Foundation Wall, , <br />.a <br />FOUNDATION WEEP SCREED <br />i <br />E WRB <br />BOND BREAK WRB <br />SF LATH <br />- <br />WRAP DP WRB ONTO <br />y <br />THE VERTICAL <br />SURFACE TO TOP OF <br />`y <br />i i-AN(A.''AS AN AIR <br />RARRIL'R <br />I j <br />I , C <br />3-1rt INCH FLANGE <br />' jlq <br />E-- THII, GAP IS A RESULT OF <br />NATURAI SHRINKAGE. <br />LX) NOT SEAL <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />LEGEND <br />Lath <br />- - Sheathing <br />Stucco <br />oK <br />Mtge] �161 <br />SELF ADHERED FLASHING (SAF) o 0 <br />DRAINAGE PLANE (UP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANi BARRIER- - - <br />Sr.LF FURRING (SF) LATH -'-- <br />PLASTER ACCESSORY <br />SIIL.A It0NG. TISB', Pt YWOOD, DENSGiASS <br />(STER STOP <br />NTINUOUS BACKLR ROD <br />EALANT <br />ME:NTITIOUS FINISH <br />STRUCTURAL FRAMINI-r <br />STnUC`T1IRAL SHEATHIW', <br />STRIP OF SAF <br />UkAINACIF. PLANE WRB <br />BOND BREAK WRB <br />SF L-ATI.1 <br />WP10 <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottorn of <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1 /2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />2 1 2023 <br />iew Assist. Inc. <br />1pleted and appl <br />the 2020 FBC 7tl <br />,le Klahr PX2300 <br />W <br />-0 <br />> <br />tU <br />o <br />ao <br />a <br />o <br />.� <br />V <br />Co <br />cQ <br />0 <br />o <br />a <br />o <br />t` <br />0 <br />to <br />p <br />> <br />o <br />.,c <br />U) <br />Q <br />cr) <br />■ <br />CU <br />V <br />CU <br />> <br />L. <br />■ <br />CL <br />Q. <br />-E"r <br />o <br />� <br />o <br />0. <br />Cn <br />ca <br />CIO <br />LLJ <br />Q <br />Z <br />Z <br />Q <br />•.J <br />CL <br />SHEET NO. <br />WP1 <br />no <br />